SIEMENS
5/10
Siemens D 35 · 2017
5
SINAMICS G120P Cabinet, converter cabinet units
SINAMICS G120P Cabinet, 75 kW to 630 kW
SINAMICS G120P Cabinet
■
Options
Refer also to ordering examples for orders with order codes.
Available options
Order code
Version A
380 ... 480 V 3 AC:
75 ... 560 kW
500 ... 690 V 3 AC:
315 ... 630 kW
Version C
380 ... 480 V 3 AC:
160 ... 400 kW
500 ... 690 V 3 AC:
315 ... 450 kW
Control Unit (it is essential to specify one of these three order codes)
CU230P-2 PN Control Unit
K96
CU230P-2 DP Control Unit
K97
CU230P-2 HVAC Control Unit
K98
Line-side options
Use in the first environment according to EN 61800-3
Category C2 (TN systems or TT systems with grounded neutral point)
1)
L00
–
Clean Power version with integrated Line Harmonics Filter
L01
3)
–
Main contactor
L13
3)
–
Main switch, incl. fuses
L26
Motor-side options
dv/dt filter compact plus VPL (Voltage Peak Limiter)
L07
–
Motor reactor
L08
–
Motor protection and safety functions
EMERGENCY OFF pushbutton installed in the cabinet door
L45
–
EMERGENCY OFF Category 0, 24 V DC
L57
3)
–
EMERGENCY STOP Category 1, 24 V DC
2)
L60
3)
–
Thermistor motor protection unit (alarm)
L83
3)
–
Thermistor motor protection unit (trip)
L84
3)
–
Pt100 evaluation unit
L86
3)
–
Safety Integrated
Stop Category 0 (STO)
K83
Stop Category 1 (SS1)
K84
Degree of protection increase
Degree of protection IP21
M21
4)
Degree of protection IP23
M23
3)
Degree of protection IP43
M43
3)
Degree of protection IP54
M54
3)
Mechanical options
Base 100 mm high
M06
Cable compartment 200 mm high, RAL 7035
M07
Other options
Switchover to a 120 V AC auxiliary power supply
K69
Provision of a cabinet-internal 230 V AC auxiliary power supply
K74
–
Connection for external auxiliary equipment
L19
3)
–
Cabinet lighting with service socket
L50
Cabinet anti-condensation heating
L55
Braking unit for line voltages 380 V... 480 V
L62
–
One-line label for system identification, 40 × 80 mm (1.57 x 3.15 in)
5)
Y31
Two-line label for system identification, 40 × 180 mm (1.57 x 7.09 in)
5)
Y32
Four-line label for system identification, 40 × 180 mm (1.57 x 7.09 in)
5)
Y33
Option that can be ordered
–
Option that cannot be ordered
1)
Applies to shielded motor cable lengths
≤
150 m (492 ft).
2)
The stopping requirements must be taken into account with this option.
Additional braking units may be required.
3)
If there is no 230 V AC power supply in the customer installation, it is
essential to select option
K74
in order to ensure proper functioning of the
option.
4)
If there is no 230 V AC power supply in the customer installation, it is
essential that option
K74
be selected in order to ensure power supply to
the fan for frame sizes F, HX and JX.
5)
The order code
Y..
requires data in plain text.
© Siemens AG 2017