SIEMENS
SINAMICS DCM
DC Converter and Control Module
Control Module
3/55
Siemens D 23.1 · 2014
3
■
Accessories
The SINAMICS DC MASTER Control Module can be split up into
several individual modules. These can be mounted separately
from one another.
Optional, pre-fabricated cable sets are available to connect the
individual modules. This means that the drive system can be
quickly but also flexibly adapted to the plant or system configu-
ration.
Description
Content
Connection
Article No.
Rear enclosure part including
accessories for mounting the
firing pulse transformer module
and/or fuse monitoring module
for a parallel connection
Set of loose parts
6RY1805-0CM00
Screws, stud bolts, and
snap-on parts to externally
mount module parts
Set of loose parts
6RY1807-0CM00
Pre-fabricated connection set
ribbon cable:
To connect the two cradles
when separately mounted
2x 26-core ribbon cables
shielded (3 m long)
1x 10-core ribbon cable
shielded (3 m long)
1x 20-core ribbon cable
shielded (3 m long)
1x RJ45 patch cable
shielded (3 m long)
from X21A, X22A on PCB -A7109-
to X21A, X22A on PCB -A7043-
from X23B on PCB -A7109- to
X23B on PCB -A7118-
from XF1 on PCB -A7109-
to XF1 on PCB -A7116-
from X45 on PCB -A7109-
to X45 on PCB -A7117-
6RY1807-0CM01
Pre-fabricated connection set
ribbon cable:
To connect the two cradles
when separately mounted
2x 26-core ribbon cables
shielded (10 m long)
1x 10-core ribbon cable
shielded (10 m long)
1x 20-core ribbon cable
shielded (10 m long)
1x RJ45 patch cable
shielded (10m long)
from X21A, X22A on PCB -A7109-
to X21A, X22A on PCB -A7043-
from X23B on PCB -A7109- to
X23B on PCB -A7118-
from XF1 on PCB -A7109-
to XF1 on PCB -A7116-
from X45 on PCB -A7109-
to X45 on PCB -A7117-
6RY1807-0CM02
Pre-fabricated connection set
for current transformer
2x 2-core twisted cables
(2 m long)
from XB on PCB -A7109- to the current transformers
6RY1707-0CM03
1)
Pre-fabricated connection set
for current transformer
2x 2-core cable
shielded (10 m long)
from XB on PCB -A7109- to the current transformers
6RY1707-0CM04
1)
Pre-fabricated connection set
for heat sink temperature
sensing
1x 2-core shielded cable
(10 m long)
from XT6 on PCB -A7109- to temperature sensor
on the heat sink
6RY1707-0CM05
1)
Pre-fabricated connection set
for firing pulse
Connection set for 12x
2-core twisted cables
(3 m long)
from XIMP11, XIMP12, XIMP13, XIMP14, XIMP15, XIMP16
XIMP21, XIMP22, XIMP23, XIMP24, XIMP25, XIMP26
to the thyristors
6RY1707-0CM06
1)
Pre-fabricated connection set
for fuse monitoring
6x 2-core twisted cables
(10 m long)
from XS1_5, XS2_5, XS3_5, XS4_5, XS5_5, XS6_5, XS7_5,
XS8_5, XS9_5, XS10_5, XS11_5, XS12_5 or XS1_4, XS2_4,
XS3_4, XS4_4, XS5_4, XS6_4, XS7_4, XS8_4, XS9_4,
XS10_4, XS11_4, XS12_4 or XS1_3, XS2_3, XS3_3, XS4__3,
XS5_3, XS6_3, XS7_3, XS8_3, XS9_3, XS10_
6RY1807-0CM07
Pre-fabricated connection set
for voltage sensing
1x 3-core twisted cable
U-V-W (3 m long)
1x 2-core twisted cable
C-D (3 m long)
from XU6, XV6, XW6 or XU5, XV5, XW5 or XU4, XV4, XW4 or
XU3, XV3, XW3 or XU2, XV2, XW2 or
XU1, XV1, XW1 depending on voltage (5.6 V, 50 V, 125 V,
250 V, 575 V or 1000 V) to supply XC6, XD6 or XC5, XD5 or
XC4, XD4 or XC3, XD3 or XC2, XD2
6RY1807-0CM08
Pre-fabricated connection set
for controlling the firing pulse
transformers
12x 2-core twisted cables
(1 m long)
from XIMP1, XIMP4 or XIMP2, XIMP5 or XIMP3, XIMP6 on
PCB -A7043- (side sections) to firing pulse transformer
modules (single boards) with terminals X11, X12, X13, X14,
X15, X16, X21, X22, X23, X24, X25, X26
6RY1707-0CM13
1)
Pre-fabricated connection set
for controlling firing pulse
transformers
2x 12-core cables, shielded
(10 m long)
from XIMP1, XIMP4 and/or XIMP2, XIMP5 and/or XIMP3,
XIMP6 on PCB -A7043- to external firing pulse
transformers
6RY1707-0CM10
1)
Pre-fabricated connection set
for mounting cradles next to
each other
2x 26-core ribbon cables
shielded (0.68 m long)
1x 10-core ribbon cable
shielded (0.5 m long)
1x 20-core ribbon cable
shielded (0.76 m long)
1x RJ45 patch cable
shielded (1 m long)
from X21A, X22A on PCB -A7109-
to X21A, X22A on PCB -A7043-
from X23B on PCB -A7109- to
X23B on PCB -A7118-
from XF1 on PCB -A7109-
to XF1 on PCB -A7116-
from X45 on PCB -A7109-
to X45 on PCB -A7117-
6RY1807-0CM11
Fuse monitoring distribution
module for parallel connection
of fuse monitors
Module including 3 m ribbon
cable to connect to the
SINAMICS DCM Control
Module; can be snapped onto
mounting rails according to
DIN EN 50022-35x7.5
X23A on Power Interface Control Module and
fuse monitor
6RY1803-0CM26
1)
Unchanged when compared to the SIMOREG DC-MASTER Control Module.
© Siemens AG 2014