SIEMENS
SINAMICS DCM
DC Converter and Control Module
DC Converter
3/35
Siemens D 23.1 · 2014
3
■
Options
(continued)
Description of options
G00
Advanced CUD left
In addition to the connections and functions of the Standard
CUD, the Advanced CUD has two DRIVE-CLiQ connections and
one option slot. The use of an Advanced CUD also provides the
opportunity of inserting an additional CUD (Standard or
Advanced) to increase the computational performance and the
number of terminals. This can be used, e.g. to implement
additional technological functions.
By using an Advanced CUD, which is located in the left-hand
slot instead of the Standard CUD, the SINAMICS components
SMC30, TM15, TM31, TM150 and CBE20 can be connected to
the SINAMICS DC MASTER, and the OALINK functionality can
also be utilized. More detailed information about the SINAMICS
components is available in the catalog section "Accessories and
supplementary components".
G10
Standard CUD right
Selecting option
G10
provides the possibility of further
increasing the performance of technology functions for the
SINAMICS DC MASTER. As a result of the additional Standard
CUD that is inserted in the right-hand slot of the electronics tray,
users have additional computational performance at their finger-
tips in order to fulfill even the highest demands when it comes to
closed-loop control performance. Option
G00
is required when
selecting option G10. An extension to include two Control Units
is only possible when the Advanced CUD is inserted in the
left-hand slot.
G11
Advanced CUD right
With option
G11
, users can address the highest demands
regarding the closed-loop control performance and use the wide
range of interfaces. With this option, in addition to the Advanced
CUD located in the left-hand slot, an additional Advanced CUD
can be mounted in the right-hand slot. This therefore doubles the
number of interfaces of the SINAMICS DC MASTER. Option
G00
is required when selecting option
G11
. An extension to include
two Control Units is only possible when the Advanced CUD is
inserted in the left-hand slot.
G20
Communication Board CBE20 left
The CBE20 Communication Board can be used to connect to a
PROFINET IO network via the Advanced CUD.
The SINAMICS DC MASTER then assumes the function of a
PROFINET IO device in the sense of PROFINET and offers the
following functions:
•
PROFINET IO device
•
100 Mbits/s full duplex
•
Supports real-time classes of PROFINET IO:
•
RT (Real-Time)
•
Connection to control systems as PROFINET IO devices in
accordance with PROFIdrive, Specification V4.
•
In addition to PROFIBUS (standard), PROFINET can also be
used for engineering with the STARTER commissioning tool.
•
Integrated 4-port switch with four RJ45 sockets based on the
PROFINET ASIC ERTEC400. The optimum topology (line, star,
tree) can therefore be configured without additional external
switches.
The following functions can also be used:
• EtherNet/IP
•
SINAMICS Link (with memory card, option S01 or S02)
The CBE20 is inserted in the option slot of the Advanced CUD,
which is inserted in the left-hand slot. An Advanced CUD must
be located in the left-hand slot in order to be able to use
option G20. This can be selected with option G00.
The cables are sold by the meter.
For further information about connectors and cables, refer to
Catalog IK PI.
Technical specifications
Permissible ambient temperature
• Storage and transport
-40 ... +70 °C
• Operation
0 ... 55 °C
Approvals
cULus (File No.: E164110)
Accessories for CBE20
Type
Industrial Ethernet FC
• RJ45 Plug 145 (1 plug)
6GK1901-1BB30-0AA0
• RJ45 Plug 145 (10 plugs)
6GK1901-1BB30-0AB0
• Stripping tool
6GK1901-1GA00
• Standard cable GP 2x2
6XV1840-2AH10
• Flexible cable GP 2x2
6XV1870-2B
• Trailing cable GP 2x2
6XV1870-2D
• Trailing cable 2x2
6XV1840-3AH10
• Marine cable 2x2
6XV1840-4AH10
© Siemens AG 2014