SIEMENS
SINAMICS DCM
DC Converter and Control Module
DC Converter
3/32
Siemens D 23.1 · 2014
3
■
Options
Note:
When ordering a unit with options, add the suffix
"-Z"
to the
Article No. of the unit and then state the order code(s) for the
desired option(s) after the suffix.
Example:
6RA8075-6GV62-0AA0-Z
G00+G20+L85+...
See also ordering examples.
Available options
The following table provides an overview of the available options. Detailed descriptions of the options are provided in the section
"Description of options".
Designation
Order code
Notes
Article No. for separate order
not coated
coated
CUD
Standard CUD left
(Standard)
–
6RY1803-0AA00-0AA1
6RY1803-0AA20-0AA1
Advanced CUD left
G00
–
6RY1803-0AA05-0AA1
6RY1803-0AA25-0AA1
Standard CUD right
G10
This option requires an Advanced CUD
left – order code
G00
6RY1803-0AA00-0AA1 +
6RY1803-0GA00
2)
6RY1803-0AA20-0AA1 +
6RY1803-0GA20
2)
Advanced CUD right
G11
This option requires an Advanced CUD
left – order code
G00
6RY1803-0AA05-0AA1 +
6RY1803-0GA00
2)
6RY1803-0AA25-0AA1 +
6RY1803-0GA20
2)
Communication Board CBE20
left
G20
This option requires an Advanced CUD
left – order code
G00
–
6SL3055-0AA00-2EB0
Communication Board CBE20
right
G21
This option requires an Advanced CUD
right – order code
G11
–
6SL3055-0AA00-2EB0
Memory card left
S01
–
6RX1800-0AS01
–
Memory card right
S02
This option requires a Standard CUD
right – order code
G10
– or an Advanced
CUD right – order code
G11
6RX1800-0AS01
–
Field
Field power section 1Q
(Standard)
–
–
1)
–
1)
Field power section 2Q
L11
Only applicable for units from 60 to
3000 A
–
1)
–
1)
Without field power section
L10
Only applicable for units from 60 to
3000 A
–
–
85 A field power section
L85
Only applicable for units from 1500 to
3000 A
–
1)
–
1)
Fans
Standard fan
(Standard)
Self-ventilated units do not have a fan
–
1)
–
Unit without fan
L20
Only applicable for units from 1500 to
3000 A
–
–
Fan for single-phase connection
L21
Only applicable for units from 400 to
1200 A
–
1)
–
Additional options
Electronics power supply for
connection to 24 V DC
L05
Standard for Control Module,
input voltage range 18 to 30 V,
current consumption 5 A at 24 V
–
1)
–
1)
Armature circuit supply with
extra-low voltage 10 to 50 V
L04
Only applicable for units up to
≤
575 V
rated supply voltage
–
1)
–
1)
Terminal Module Cabinet
G63
–
6RY1803-0AB05
–
Coated PCBs
M08
–
–
–
Nickel-plated copper busbars
M10
Only applicable for units from 60 to
3000 A
–
–
External sensor for ambient or
inlet temperature
L15
–
–
1)
–
Control for switching over the
power section topology for
parallel and series connections
S50
–
–
–
Extension of the liability for
defects
Q80 ... Q85
See section "Description of options"
–
–
1)
Available as spare part.
2)
The Standard CUD (uncoated 6RY1803-0AA00-0AA1; coated 6RY1803-
0AA20-0AA1) and the Advanced CUD (uncoated 6RY1803-0AA05-0AA1;
coated 6RY1803-0AA25-0AA1) can be inserted in either the left-hand or the
right-hand slot and therefore have an article number which does not refer to
a specific slot. A Connector Board (6RY1803-0GA00 or 6RY1803-0GA20) is
also needed in order to retrofit a CUD.
© Siemens AG 2014