SIEMENS
SINAMICS DCM
DC Converter and Control Module
DC Converter
3/21
Siemens D 23.1 · 2014
3
■
Technical specifications
(continued)
SINAMICS DC MASTER converters for 400 V 3 AC, 15 to 125 A, four-quadrant operation
Note:
Detailed dimensional drawings in PDF and DXF format are
available on the Internet at
.
Data for single-phase connection
Type
6RA8013-
6DV62-0AA0
6RA8018-
6DV62-0AA0
6RA8025-
6DV62-0AA0
6RA8028-
6DV62-0AA0
6RA8031-
6DV62-0AA0
Rated armature supply
voltage
1)
V
400 3 AC
(+15/-20 %)
Rated armature input current
A
12
25
50
75
104
Rated supply voltage,
electronics power supply
V
380 (-25 %) … 480 (+10 %) 2 AC;
I
n
= 1 A or
190 (-25 %) … 240 (+10 %) 2 AC;
I
n
= 2 A
Rated fan supply voltage
V
Self-ventilated
Rated fan current
A
Cooling air requirement
m
3
/h
Sound pressure level
2)
dB (A)
Rated field supply voltage
1)
V
400 2 AC
(+15/-20 %)
Rated frequency
Hz
45 … 65
Rated DC voltage
1)
V
420
Rated DC current
A
15
30
60
90
125
Overload capability
x
×
I
n
1.8
Rated power
kW
6.3
12.6
25
38
53
Power loss at rated DC current
kW
0.13
0.18
0.25
0.32
0.41
Rated DC field voltage
1)
V
Max. 325
Rated DC field current
A
3
5
10
Normal ambient temperature
in operation
3)
°C
0 … +45
Storage and transport
temperature
°C
-40 … +70
Installation altitude above
sea level
3)
≤
1000 m for rated DC current
Dimensions
• Width
mm
268
• Height
mm
385
• Depth
mm
221
252
Weight, approx.
kg
11
14
Type
6RA8013-
6DV62-0AA0
6RA8018-
6DV62-0AA0
6RA8025-
6DV62-0AA0
6RA8028-
6DV62-0AA0
6RA8031-
6DV62-0AA0
Rated DC voltage
V
280
Rated DC current
A
10.5
21.0
42.0
63.0
87.5
1)
The armature/field supply voltage may be lower than the rated armature/
field voltage (set by parameter). A minimum input voltage of 50 V is permis-
sible for units with a rated voltage of 400 V, 480 V and 575 V, or 85 V for
higher rated voltages. The output voltage is reduced accordingly. The
specified DC output voltage can be maintained up to an undervoltage of
5 % of the line supply voltage (rated armature/field supply voltage).
2)
Fan noise for a unit installed in an IP20 electrical cabinet (door closed,
50 Hz operation or operation at 24 V DC for units with an internal supply).
3)
For derating factors at higher temperatures and installation altitudes,
see page 3/8.
© Siemens AG 2014