SIEMENS
SINAMICS DCM
Services and documentation
SINAMICS DCM demonstration case
7/2
Siemens D 23.1 · 2014
7
■
Overview
Demonstration case, opened
The SINAMICS DC MASTER demonstration model is installed
ready to be connected-up in a rugged transport case and is
immediately ready for operation. It comprises a DC converter
480 V 3 AC, DC 30 A, a 0.55 kW DC motor as well as numerous
options and accessories. The case has two integrated transport
wheels and a hinged handle.
Scope of delivery
The following main components are included in the SINAMICS
DC MASTER demonstration case, including all of the required
wiring, connection and signal cables:
•
DC converter 6RA8018-6FV62-0AA0-Z;
Z=G00+G10+G20+S01+L05
G00 = Advanced CUD left
G10 = Standard CUD right
G20 = Communication Board CBE20 left
S01
= Memory card left
L05
= Electronics power supply for connection to 24 V DC
Option L05 permits operation on a three-phase line supply or a
single-phase line supply, e.g. 230 V. Presentations or training
courses can be carried out locally without requiring a three-
phase supply; for instance in hotels or office buildings.
•
TM31 Terminal Module
•
TM15 Terminal Module
•
AOP30 Advanced Operator Panel
•
Radio interference suppression filter
•
Three-phase commutating reactor for the armature circuit
•
Single-phase commutating reactor for the field circuit
•
DC motor 0.55 kW, 1750 rpm
•
Pulse encoder OG 60 DN 2040 CI
•
Analog tachometer GT 5.05 L/410,
V
o
= 10 V/1000 rpm
•
Commissioning box for SINAMICS DC MASTER to control
analog and digital inputs and outputs
Free function blocks and Drive Control Chart can be used
without any restrictions.
The demonstration case is also available without integrated
DC
motor to operate an externally mounted DC motor. (The rated
converter data must be observed.)
■
Application
•
Demonstrating DC drives to customers
•
Training Siemens employees and customers
•
Test configurations
An automation group using a SIMATIC demonstration case
together with one or several SINAMICS DC MASTER
demonstration cases can be implemented.
■
Function
Operation
The converter can be operated from:
•
the commissioning box, which is connected to the terminals of
the unit or the TM15 and TM31
•
the AOP30 operator panel
•
the PROFIBUS interface
•
the PROFINET interface
A description is provided with the demonstration case. This
clearly shows the principle operator panel design and the
possible functions of the operator controls.
To use the STARTER commissioning tool, users require a
programming device or PC. The system requirements are
described in section STARTER.
■
Technical specifications
■
Selection and ordering data
The demonstration case with integrated DC motor is also
available for rental.
Please contact your regional Siemens sales person.
SINAMICS DCM demonstration case
Line supply connection
Supply voltage
110 … 480 V 3 AC
(+15 %/-20 %)
or
110 … 480 V 1 AC
(+15 %)
Rated frequency
45 … 65 Hz
Connecting cables
with 16 A Cecon connector
(5UR5076 3), length approx. 4 m
and a 0.7 m long adapter cable
with Cecon socket and connec-
tor with ground connection
Line connection fusing required
16 A
Dimensions and weights
Width
approx. 680 mm
Height
approx. 700 mm
Depth
approx. 430 mm
Weight with integrated DC motor
approx. 70 kg
Weight without motor
approx. 55 kg
SINAMICS DCM demonstration case
Description
Order No.
With integrated DC motor
6RX1800-0SM00
Without motor
6RX1800-0SV00
© Siemens AG 2014