SIEMENS
SINAMICS DCM
Engineering information
Notes for EMC-compliant drive installation
5/26
Siemens D 23.1 · 2014
5
■
Overview
(continued)
Radio interference suppression filter for the
SINAMICS DC MASTER field power section
Radio interference suppression filter
Shield connection
Shield connection
$
Connecting terminal on a copper bar, max. cable diameter
15 mm
%
Bar-mounting terminal on a copper bar, max. cable diameter
10 mm
&
Metallic tube or cable tie on a bare metallic comb-type/
toothed bar
(
Clamp with metallic backing plate on cable support rail
L1
L2
L3
NETZ/LINE
LAST/LOAD
L1 L2 L3
Separate
unfiltered
and
filtered
cables
Separate
unfiltered
and
filtered
cables
Connect the line filter to the cabinet enclosure
through large surface area
Line
con-
nection
Connect protective
conductor
Power section
connection,
field circuit
G_D023_EN_00018
G_D023_XX_00019
1
2
3
4
© Siemens AG 2014