SIEMENS
ROBICON Perfect Harmony
Liquid-cooled drives
4/8
Siemens D 16.2
– 2012
4
Options
Description of Options
V01 to V14
Motor voltages
With the options
V01
to
V14
, the motor voltage can be
selected. These options are mutually exclusive. Select one
of them.
Option
Motor voltage
V01
2.3 kV
V02
2.4 kV
V03
3.0 kV
V04
3.3 kV
V05
4.0 kV
V06
4.16 kV
V07
4.8 kV
V08
5.0 kV
V09
5.5 kV
V10
6.0 kV
V11
6.3 kV
V12
6.6 kV
V13
6.9 kV
V14
7.2 kV
W31, W32
Design of cooling
With options
W31
or
W32
, a heat exchanger is provided
to cool the power components and transformer. They are
mutually exclusive. For further details, please contact the
factory or your local Siemens sales representative.
Option
Description
W31
Drive prepared for liquid-liquid heat exchanger
W32
Drive prepared for liquid-air heat exchanger
Note: The heat exchangers are not integral to the drive lineup
and require outside installation by customer.
Note: One heat exchanger unit is required per drive system.
Example of liquid-liquid heat exchanger
Plate and Frame Heat Exchanger
U03
Version with CSA certification
With option
U03
, a drive version certified by the Canadian
Standards Association (CSA) is supplied.
Note: Option
U03
includes option
M08
(mechanical door
interlocks – Superior).
U02, U04 combination
version with CE and GOST certification
With the combination of
U02
and
U04
, a drive version with
CE and GOST conformity is supplied.
Note: When options
U02
and
U04
are combined, options
L03
(EMC filter) and option
M12
(electrical door interlocks)
are included.
U10
ProToPS
With option
U10
, the control system Process Tolerant
Protection Strategy (ProToPS) is integrated – a ground-
breaking process control system available exclusively from
Siemens. Instead of tripping the drive and automatically
shutting down the system due to a malfunction, ProToPS
provides a hierarchical system of warnings in advance of
potential drive system trip. This control strategy allows time
to evaluate the situation and respond appropriately to avoid
a system shutdown.
Note: Option
U10
includes the options
U11
(cell bypass).
Note: Contact the factory or your local Siemens sales
representative for option
U10
.
U11
Cell bypass
With option
U11
, the drive system will automatically
continue to operate uninterrupted if one or more cells
has a fault. The continuous current rating is maintained
with faulted cells but at a reduced voltage. This is a
recommended option for critical processes. Faulted
cells can then be replaced at a convenient planned
maintenance window.
Note: Option
U11