SIEMENS
ROBICON Perfect Harmony
Liquid-cooled drives
3
3/15
Siemens D 16.2 – 2012
Type specific technical data
(continued)
ROBICON Perfect Harmony
liquid-cooled drive version
6SR3252-
2.B48-0..0
6SR3252-
2.B48-5..0
6SR3252-
2.B48-7..0
6SR3252-
2.B48-8..0
6SR3252-
2.B52-0..0
6SR3252-
2.B52-2..0
6SR3252-
2.B52-4..0
Motor voltage 6.6 kV
Max. output voltage
kV
6.6
6.6
6.6
6.6
6.6
6.6
6.6
Type rating
kVA
7030
7470
7910
8350
8780
9660
10055
Shaft output
1)
hp
kW
8000
5968
8500
6341
9000
6714
9500
7087
10000
7460
11000
8206
11450
8542
Typical motor current
1)
A
614.79
653.21
691.64
730.06
768.49
845.34
880.00
Power cell current
A
880
880
880
880
880
880
880
Number of cells
15
15
15
15
15
15
15
Transformer rating
kVA
8000
8500
9000
9500
10000
11000
12000
Power losses of drive system
• Copper transformer
kW
< 280
< 298
< 315
< 333
< 350
< 385
< 420
Efficiency P
out
/P
in
2)
of
drive system
• Copper transformer
%
96.5
96.5
96.5
96.5
96.5
96.5
96.5
Auxiliary supply
• Single-phase w/o options
3)
kVA
2.5
2.5
2.5
2.5
2.5
2.5
2.5
• Single-phase w/ all options
3)
kVA
2.5
2.5
2.5
2.5
2.5
2.5
2.5
• Three-phase w/o CPT
4)
kVA
25
25
25
25
25
25
25
• Three-phase w/ CPT and all
-options
4)
kVA
27.5
27.5
27.5
27.5
27.5
27.5
27.5
System pre-charge
5)
%
< 0.5
< 0.5
< 0.5
< 0.5
< 0.5
< 0.5
< 0.5
Cooling water requirement
—
Determined by actual design of external liquid-to-air or liquid-to-liquid heat exchanger
Power cabling cross sections
6)
• Cable cross-sections,line-side,
max. connectable per phase
with ½” bolt
AWG/MCM
(NEC,CEC)
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
mm
2
(DIN VDE)
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
• Cable cross-sections,
motor-side, max.
connectable per phase
with ½” bolt
AWG/MCM
(NEC, CEC)
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
2 x 1000
MCM
mm
2
(DIN VDE)
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
• PE
7)
connection, max.
connection cross-section at
enclosure with ½” bolt
AWG/MCM
(NEC, CEC)
1000 MCM
1000 MCM
1000 MCM
1000 MCM
1000 MCM
1000 MCM
1000 MCM
mm
2
(DIN VDE)
500
500
500
500
500
500
Degree of protection
MV
LV
NEMA 12/ IP54
NEMA 1/IP21
NEMA 12/ IP54
NEMA 1/IP21
NEMA 12/ IP54
NEMA 1/IP21
NEMA 12/ IP54
NEMA 1/IP21
NEMA 12/ IP54
NEMA 1/IP21
NEMA 12/ IP54
NEMA 1/IP21
NEMA 12/ IP54
NEMA 1/IP21
Drive dimensions (overall drive dimensions)
• Width
in
mm
433
11100
433
11100
433
11100
433
11100
439
11150
439
11150
439
11150
• Height
in
mm
115
2920
115
2920
115
2920
115
2920
115
2920
115
2920
115
2920
• Depth
in
mm
66
1680
66
1680
66
1680
66
1680
70
1780
70
1780
70
1780
• Dimension drawing
8)
A
A
A
A
A
A
A
Drive weight (cell cabinet and transformer cabinet)
• Weight
9)
lb
kg
50956
23114
51771
23483
52563
23843
53333
24192
54084
24533
55533
25190
56919
25818
1)
The Specifications for the typical motor current and the power data in
hp and kW are approximate values only; these have been calculated for
operation with induction motors and for a typical power factor
c
s
and motor efficiency. Both approximate values have to be adapted to
the motor that is actually used.
2)
Values at 100% of rated speed and torque; includes drive and input
transformer.
3)
120/240 V AC for NXGII control and 120 V AC internal heat exchanger
in water-cooled systems.
4)
Includes cooling blowers/pumps; largest unit shown. CPT: Control
power transformer.
5)
Percentage of transformer kVA.
6)
Maximum installable size per phase.
7)
PE - Protective Earth.
8)
For dimension drawings please refer to Section 5, pg 5/11.
9)
Drive Weight is based on cell cabinet, transformer cabinet, and coolant
cabinet only.
Type Specific Technical Data