SIEMENS
ROBICON Perfect Harmony
Liquid-cooled drives
2
2/11
Siemens D 16.2 – 2012
Selection and ordering data (continued)
Selection and Ordering Data
Motor voltage 4.0/4.16 kV
Motor
voltage
Type
rating
Shaft
output
1)
Shaft
output
1)
Typical
motor
current
1)
Power
cell
current
Number
of cells
Transformer
rating
Order number
Generation
kV
kVA
hp
kW
A
A
kVA
4.0/4.16
3950
4500
3357
570.60
880
9
4500
6SR3252-0
B44-5
0
WCIII
4.0/4.16
4390
5000
3730
634.00
880
9
5000
6SR3252-0
B45-0
0
WCIII
4.0/4.16
4830
5500
4103
697.40
880
9
5500
6SR3252-0
B45-5
0
WCIII
4.0/4.16
5270
6000
4476
760.80
880
9
6000
6SR3252-0
B46-0
0
WCIII
4.0/4.16
5710
6500
4849
824.20
880
9
6500
6SR3252-0
B46-5
0
WCIII
4.0/4.16
6095
6940
5177
880.00
880
9
7000
6SR3252-0
B47-0
0
WCIII
4.0/4.16
6150
7000
5222
887.60
1250
9
7000
6SR3252-0
C47-0
0
WCIII
4.0/4.16
6590
7500
5595
951.00
1250
9
7500
6SR3252-0
C47-5
0
WCIII
4.0/4.16
7030
8000
5968
1014.40
1250
9
8000
6SR3252-0
C48-0
0
WCIII
4.0/4.16
7470
8500
6341
1077.80
1250
9
8500
6SR3252-0
C48-5
0
WCIII
4.0/4.16
7910
9000
6714
1141.20
1250
9
9000
6SR3252-0
C48-7
0
WCIII
4.0/4.16
8350
9500
7087
1204.60
1250
9
9500
6SR3252-0
C48-8
0
WCIII
4.0/4.16
8660
9858
7354
1250.00
1250
9
10000
6SR3252-0
C52-0
0
WCIII
1)
The specifications for the typical motor current and the power data in hp and kW are approximate values only; these have been calculated for
operation with induction motors and for typical power factor co-efficiency. Both approximate values have to be adapted to the motor that is
actually used.
For Order Number Supplements, see pages
2-15 to 2-18