SIEMENS
1/90
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
4-pole: 1500 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 155 (F)
– can be ordered with additional
1PS
070-1BD..-.BA4
-071BR-04.
0.25
0.30
2.12
1393
0.83
95
0.30
0.82
1PS
071-1BD
....
BA4
-071BS-04.
0.37
0.45
3.19
1362
1.12
85
0.45
1.10
1PS
080-1BD..-.BA4
-080BR-04.
0.55
0.65
4.58
1425
1.56
94
0.65
1.50
1PS
081-1BD..-.BA4
-080BS-04.
0.75
0.90
6.20
1425
2.00
94
0.90
1.95
1PS
095-1BD..-.BA4
-090LR-04.
1.10
1.30
9.20
1412
2.90
88
1.30
2.80
1PS
098-1BD..-.BA4
-090LS-04.
1.50
1.80
12.6
1412
3.85
100
1.80
3.75
1PS
106-1BD..-.BA4
-100LR-04.
2.20
2.70
18.1
1443
5.40
100
2.70
5.30
1PS
108-1BD..-.BA4
-100LS-04.
3.00
3.70
24.7
1443
7.30
94
3.70
7.20
1PS
113-1BD..-.BA4
-112MS-04.
4.00
4.40
29.3
1455
8.90
100
4.40
8.80
1PS
131-1BD..-.BA4
-132SR-04.
5.50
6.40
42.4
1459
12.8
94
6.40
12.7
1PS
133-1BD..-.BA4
-132MS-04.
7.50
8.30
54.7
1461
16.1
99
8.30
16.0
1PS
163-1BD..-.BA4
-160MR-04.
11.0
12.9
84.6
1464
24.0
91
12.9
23.5
1PS
166-1BD..-.BA4
-160LS-04.
15.0
17.7
115
1470
32.0
97
17.7
32.0
1PS
183-1BD..-.BA4
-180MR-04.
18.5
19.8
129.4
1462
37.0
100
19.8
37.0
1PS
186-1BD..-.BA4
-180LS-04.
22.0
22.6
147.7
1464
42.0
100
22.6
42.0
1PS
206-1BD..-.BA4
-200LS-04.
30.0
32.1
209
1468
59.0
100
32.1
59.0
1PS
220-1BD..-.BA4
-225SR-04.
37.0
38.0
248
1469
67.0
87
38.0
67.0
1PS
223-1BD..-.BA4
-225MS-04.
45.0
46.3
300
1474
82.0
87
46.3
82.0
1PS
253-1BD..-.BA4
-250MM-04.
55.0
56.6
366
1479
102
80
56.6
102
1PS
280-1BD..-.BA4
-280SL-04.
75.0
83.5
540
1483
147
75
83.5
146
1PS
283-1BD..-.BA4
-280MM-04.
90.0
92.5
596
1486
163
75
92.5
162
1PS
311-1BD..-.BA4
-315SL-04.
110
130
835
1488
225
65
130
225
1PS
313-1BD..-.BA4
-315ML-04.
132
147.5
947
1489
255
65
147.5
255
1PS
315-1BD..-.BA4
-315MN-04.
160
164.5
1056
1490
285
65
164.5
285
1PS
316-1BD..-.BA4
-315LL-04.
200
205
1320
1490
360
65
205
355
1PS
317-1BD..-.BA2
-315LM-04.
250
231
1488
1488
405
65
231
405
1PS
0
356-1BD..-0BA2
A N G A
-355LB-04.
315
290
1874
1491
520
60
290
520
1PS
1
356-1BD..-3BA3
A N G K
-355LB-04.
315
290
1874
1491
520
60
290
520
1PS
5
353-1BD..-4BA3
D N G W
-355MR-04.
315
292
1874
1489
520
60
292
520
1PS
5
355-1BD..-4BA3
D N G W
-355MS-04.
360
333
2142
1489
600
60
333
600
1PS
5
357-1BD..-4BA3
D N G W
-355MT-04.
460
426
2737
1489
750
60
426
750
Motor
0
A N G A
LOHER CHEMSTAR 1PS0
1
A N G K
LOHER CHEMSTAR 1PS1 (converter operation Ex nA can only be ordered with add. identification code
-Z
and order code
M73
)
5
D N G W
LOHER CHEMSTAR 1PS5
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016