SIEMENS
1/88
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
4-pole: 1500 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 130 (B)
1PS
070-1BD..-.BA4
-071BR-04.
0.25
0.28
1.91
1404
0.80
100
0.28
0.80
1PS
071-1BD
....
BA4
-071BS-04.
0.37
0.41
2.87
1376
1.06
95
0.41
1.05
1PS
080-1BD..-.BA4
-080BR-04.
0.55
0.60
4.12
1432
1.47
100
0.60
1.44
1PS
081-1BD..-.BA4
-080BS-04.
0.75
0.80
5.60
1432
1.88
100
0.80
1.81
1PS
095-1BD..-.BA4
-090LR-04.
1.10
1.20
8.30
1421
2.70
98.0
1.20
2.65
1PS
098-1BD..-.BA4
-090LS-04.
1.50
1.60
11.3
1421
3.60
100
1.60
3.45
1PS
106-1BD..-.BA4
-100LR-04.
2.20
2.40
16.3
1449
4.95
100
2.40
4.80
1PS
108-1BD..-.BA4
-100LS-04.
3.00
3.30
22.3
1449
6.70
100
3.30
6.50
1PS
113-1BD..-.BA4
-112MS-04.
4.00
4.00
26.4
1460
8.30
100
4.00
8.20
1PS
131-1BD..-.BA4
-132SR-04.
5.50
5.80
38.2
1463
11.8
100
5.80
11.7
1PS
133-1BD..-.BA4
-132MS-04.
7.50
7.50
49.3
1465
14.8
100
7.50
14.7
1PS
163-1BD..-.BA4
-160MR-04.
11.0
11.7
76.1
1468
22.0
100
11.7
22.0
1PS
166-1BD..-.BA4
-160LS-04.
15.0
15.9
103.5
1473
29.5
100
15.9
29.5
1PS
183-1BD..-.BA4
-180MR-04.
18.5
17.8
116.4
1466
34.0
100
17.8
33.5
1PS
186-1BD..-.BA4
-180LS-04.
22.0
20.4
132.9
1468
39.0
100
20.4
39.0
1PS
206-1BD..-.BA4
-200LS-04.
30.0
28.9
188.2
1471
54.0
100
28.9
54.0
1PS
220-1BD..-.BA4
-225SR-04.
37.0
34.3
223
1472
61.0
87
34.3
61.0
1PS
223-1BD..-.BA4
-225MS-04.
45.0
41.7
270
1477
75.0
87
41.7
75.0
1PS
253-1BD..-.BA4
-250MM-04.
55.0
51.0
329
1481
93.0
80
51.0
93.0
1PS
280-1BD..-.BA4
-280SL-04.
75.0
75.5
486
1485
133
75
75.5
133
1PS
283-1BD..-.BA4
-280MM-04.
90.0
83.0
536
1487
148
75
83.0
148
1PS
311-1BD..-.BA4
-315SL-04.
110
117
751
1489
205
65
117
205
1PS
313-1BD..-.BA4
-315ML-04.
132
132.5
852
1490
230
65
132.5
230
1PS
315-1BD..-.BA4
-315MN-04.
160
148
951
1491
260
65
148
260
1PS
316-1BD..-.BA4
-315LL-04.
200
185
1188
1491
325
65
185
325
1PS
317-1BD..-.BA2
-315LM-04.
250
231
1488
1488
405
65
231
405
1PS
0
356-1BD..-0BB2
A N G A
-355LB-04.
315
290
1874
1491
520
60
290
520
1PS
1
356-1BD..-3BB2
A N G K
-355LB-04.
315
290
1874
1491
520
60
290
520
1PS
5
353-1BD..-4BA3
D N G W
-355MR-04.
315
292
1874
1489
520
60
292
520
1PS
5
355-1BD..-4BA3
D N G W
-355MS-04.
360
333
2142
1489
600
60
333
600
1PS
5
357-1BD..-4BA3
D N G W
-355MT-04.
460
426
2737
1489
750
60
426
750
Motor
0
A N G A
LOHER CHEMSTAR 1PS0
1
A N G K
LOHER CHEMSTAR 1PS1 (converter operation Ex nA can only be ordered with add. identification code
-Z
and order code
M73
)
5
D N G W
LOHER CHEMSTAR 1PS5
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016