SIEMENS
1/86
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
2-pole: 3000 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 155 (F)
– can be ordered with additional
1PS
070-1BD..-.AA4
-071BR-02.
0.37
0.45
1.55
2824
1.02
95
0.45
1.00
1PS
071-1BD
....
AA4
-071BS-02.
0.55
0.65
2.31
2812
1.51
88
0.65
1.46
1PS
080-1BD..-.AA4
-080BR-02.
0.75
0.85
3.02
2769
1.85
74
0.85
1.79
1PS
081-1BD..-.AA4
-080BS-02.
1.10
1.30
4.65
2793
2.80
82
1.30
2.65
1PS
095-1BD..-.AA4
-090LR-02.
1.50
1.80
6.20
2862
3.65
100
1.80
3.55
1PS
098-1BD..-.AA4
-090LS-02.
2.20
2.40
8.10
2877
4.85
100
2.40
4.75
1PS
106-1BD..-.AA4
-100LS-02.
3.00
3.50
11.7
2893
6.80
100
3.50
6.70
1PS
113-1BD..-.AA4
-112MS-02.
4.00
4.20
13.9
2936
8.20
100
4.20
8.10
1PS
131-1BD..-.AA4
-132SR-02.
5.50
6.10
20.0
2933
11.4
90
6.10
11.3
1PS
132-1BD..-.AA4
-132SS-02.
7.50
8.00
26.0
2946
14.5
90
8.00
14.4
1PS
163-1BD..-.AA4
-160MR-02.
11.0
12.9
42.1
2947
23.0
80
12.9
23.0
1PS
165-1BD..-.AA4
-160MS-02.
15.0
16.0
52.0
2952
29.0
80
16.0
28.5
1PS
166-1BD..-.AA4
-160LS-02.
18.5
19.0
61.6
2954
34.0
80
19.0
34.0
1PS
183-1BD..-.AA4
-180MS-02.
22.0
22.6
73.6
2938
40.5
76
22.6
40.5
1PS
206-1BD..-.AA4
-200LR-02.
30.0
35.4
114.8
2947
62.0
75
35.4
62.0
1PS
208-1BD..-.AA4
-200LS-02.
37.0
39.6
128.1
2957
69.0
75
39.6
69.0
1PS
223-1BD..-.AA4
-225MS-02.
45.0
48.2
155.5
2962
84.0
75
48.2
84.0
1PS
253-1BD..-.AA4
-250MM-02.
55.0
56.6
182.1
2969
98.0
65
56.6
98.0
1PS
280-1BD..-.AA4
-280SL-02.
75.0
80.0
258
2976
141
60
80.0
140
1PS
283-1BD..-.AA4
-280MM-02.
90.0
92.5
298
2974
161
60
92.5
161
1PS
311-1BD..-.AA4
-315SL-02.
110
130
417
2979
220
60
130
220
1PS
313-1BD..-.AA4
-315ML-02.
132
141.5
454
2981
235
60
141.5
235
1PS
315-1BD..-.AA4
-315MN-02.
160
164.5
528
2981
270
60
164.5
270
1PS
316-1BD..-.AA4
-315LL-02.
200
205
660
2981
340
60
205
340
1PS
318-1BD..-.AA4
-315LN-02.
250
231
741
2986
385
60
231
380
1PS
0
356-1BD..-0AA2
A N G A
-355LB-02.
315
290
934
2985
495
60
290
495
1PS
1
356-1BD..-3AA2
A N G K
-355LB-02.
315
290
934
2985
495
60
290
495
1PS
5
353-1BD..-4AA3
D N G W
-355MR-02.
315
292
934
2985
500
60
292
500
1PS
5
355-1BD..-4AA3
D N G W
-355MS-02.
360
333
1068
2985
570
60
333
570
1PS
5
357-1BD..-4AA3
D N G W
-355MT-02.
460
426
1364
2986
710
60
426
710
Motor
0
A N G A
LOHER CHEMSTAR 1PS0
1
A N G K
LOHER CHEMSTAR 1PS1 (converter operation Ex nA can only be ordered with add. identification code
-Z
and order code
M73
)
5
D N G W
LOHER CHEMSTAR 1PS5
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016