SIEMENS
1/82
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
6-pole: 1000 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 155 (F)
– can be ordered with additional
1MD50701BD..4CA1
DNGW-071BS-06.
0.25
0.25
2.86
835
0.81
86
0.25
0.80
1MD50801BD..4CA1
DNGW-080BR-06.
0.37
0.38
3.93
923
1.08
89
0.38
1.08
1MD50811BD..4CA1
DNGW-080BS-06.
0.55
0.55
5.80
906
1.65
100
0.55
1.63
1MD50951BD..4CA1
DNGW-090LR-06.
0.75
0.75
7.90
907
2.05
93
0.75
2.05
1MD50981BD..4CA1
DNGW-090LS-06.
1.10
1.10
11.6
906
2.95
96
1.10
2.90
1MD51061BD..4CA1
DNGW-100LS-06.
1.50
1.50
15.2
942
3.80
100
1.50
3.70
1MD51131BD..4CA1
DNGW-112MS-06.
2.20
2.20
22.4
938
5.30
100
2.20
5.20
1MD51311BD..4CA1
DNGW-132SR-06.
3.00
3.00
30.4
942
7.30
93
3.00
7.20
1MD51331BD..4CA1
DNGW-132MR-06.
4.00
4.10
40.6
964
9.30
85
4.10
9.20
1MD51351BD..4CA1
DNGW-132MS-06.
5.50
5.50
56.0
938
12.4
96
5.50
12.1
1MD51631BD..4CA1
DNGW-160MR-06.
7.50
7.50
76.0
942
17.1
81
7.50
16.8
1MD51661BD..4CA1
DNGW-160LS-06.
11.0
11.0
111
946
24.0
82
11.0
23.5
1MD51861BD..4CA1
DNGW-180LS-06.
15.0
15.0
151
949
31.5
100
15.0
31.0
1MD52061BD..4CA1
DNGW-200LR-06.
18.5
19.0
186
975
37.0
85
19.0
37.0
1MD52081BD..4CA1
DNGW-200LS-06.
22.0
22.5
221
972
43.5
80
22.5
43.5
1MD52231BD..4CA1
DNGW-225MS-06.
30.0
30.5
301
968
58.0
87
30.5
58.0
1MD52531BD..4CA1
DNGW-250MM-06.
37.0
38.0
371
978
72.0
80
38.0
71.0
1MD52801BD..4CA1
DNGW-280SL-06.
45.0
46.0
449
978
86.0
75
46.0
85.0
1MD52831BD..4CA1
DNGW-280MM-06.
55.0
56.5
549
983
102
75
56.5
102
1MD53111BD..4CA1
DNGW-315SL-06.
75.0
77.0
747
984
141
65
77.0
141
1MD53131BD..4CA1
DNGW-315ML-06.
90.0
92.0
896
981
169
65
92.0
168
1MD53141BD..4CA1
DNGW-315MM-06.
110
113
1095
985
200
65
113
200
1MD53151BD..4CA1
DNGW-315MN-06.
132
135
1314
981
240
65
135
240
1MD53161BD..4CA1
DNGW-315LL-06.
160
164
1593
983
290
65
164
290
1MD53171BD..4CA1
DNGW-315LM-06.
200
185
1788
988
345
65
185
345
1MD53531BD..4CA1
DNGW-355MR-06.
280
259
2496
991
485
60
259
480
1MD53551BD..4CA1
DNGW-355MS-06.
315
292
2808
993
540
60
292
540
1MD53571BD..4CA1
DNGW-355MT-06.
360
333
3206
992
610
60
333
610
1)
The reduced torque in the field-weakening range shall be calculated as
follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016