SIEMENS
1/80
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
6-pole: 1000 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 130 (B)
1MD50701BD..4CA1
DNGW-071BS-06.
0.25
0.23
2.57
855
0.79
95
0.23
0.79
1MD50801BD..4CA1
DNGW-080BR-06.
0.37
0.34
3.54
917
1.04
99
0.34
1.03
1MD50811BD..4CA1
DNGW-080BS-06.
0.55
0.50
5.20
918
1.57
100
0.50
1.56
1MD50951BD..4CA1
DNGW-090LR-06.
0.75
0.65
7.10
874
1.96
100
0.65
1.90
1MD50981BD..4CA1
DNGW-090LS-06.
1.10
1.00
10.4
918
2.80
100
1.00
2.90
1MD51061BD..4CA1
DNGW-100LS-06.
1.50
1.30
13.7
906
3.55
100
1.30
3.40
1MD51131BD..4CA1
DNGW-112MS-06.
2.20
2.00
20.2
945
4.90
100
2.00
4.85
1MD51311BD..4CA1
DNGW-132SR-06.
3.00
2.70
27.4
941
7.00
100
2.70
6.90
1MD51331BD..4CA1
DNGW-132MR-06.
4.00
3.70
36.5
968
8.70
95
3.70
8.70
1MD51351BD..4CA1
DNGW-132MS-06.
5.50
5.10
50.0
974
11.6
100
5.10
11.6
1MD51631BD..4CA1
DNGW-160MR-06.
7.50
6.50
68.0
913
15.9
90
6.50
15.3
1MD51661BD..4CA1
DNGW-160LS-06.
11.0
10.0
100
955
22.5
91
10.0
22.0
1MD51861BD..4CA1
DNGW-180LS-06.
15.0
13.5
136
948
29.5
100
13.5
29.0
1MD52061BD..4CA1
DNGW-200LR-06.
18.5
17.0
167
972
34.0
85
17.0
33.5
1MD52081BD..4CA1
DNGW-200LS-06.
22.0
20.0
199
960
40.0
80
20.0
39.5
1MD52231BD..4CA1
DNGW-225MS-06.
30.0
27.5
271
969
53.0
87
27.5
53.0
1MD52531BD..4CA1
DNGW-250MM-06.
37.0
34.0
334
972
65.0
80
34.0
65.0
1MD52801BD..4CA1
DNGW-280SL-06.
45.0
41.5
404
981
78.0
75
41.5
78.0
1MD52831BD..4CA1
DNGW-280MM-06.
55.0
51.0
494
986
93.0
75
51.0
93.0
1MD53111BD..4CA1
DNGW-315SL-06.
75.0
69.5
672
988
129
65
69.5
129
1MD53131BD..4CA1
DNGW-315ML-06.
90.0
83.0
806
983
154
65
83.0
153
1MD53141BD..4CA1
DNGW-315MM-06.
110
102
986
988
183
65
102
183
1MD53151BD..4CA1
DNGW-315MN-06.
132
122
1183
985
220
65
122
220
1MD53161BD..4CA1
DNGW-315LL-06.
160
148
1434
986
265
65
148
265
1MD53171BD..4CA1
DNGW-315LM-06.
200
185
1788
988
345
65
185
345
1MD53531BD..4CA1
DNGW-355MR-06.
280
259
2496
991
485
60
259
480
1MD53551BD..4CA1
DNGW-355MS-06.
315
292
2808
993
540
60
292
540
1MD53571BD..4CA1
DNGW-355MT-06.
360
333
3206
992
610
60
333
610
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016