SIEMENS
1/78
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
4-pole: 1500 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 155 (F)
– can be ordered with additional
1MD50701BD..4BA1
DNGW-071BR-04.
0.25
0.25
1.74
1372
0.80
100
0.25
0.79
1MD50711BD..4BA1
DNGW-071BS-04.
0.37
0.38
2.62
1385
1.03
100
0.38
1.03
1MD50801BD..4BA1
DNGW-080BR-04.
0.55
0.55
3.76
1397
1.39
100
0.55
1.37
1MD50811BD..4BA1
DNGW-080BS-04.
0.75
0.75
5.1
1404
1.82
100
0.75
1.79
1MD50951BD..4BA1
DNGW-090LR-04.
1.10
1.10
7.6
1382
2.55
100
1.10
2.50
1MD50981BD..4BA1
DNGW-090LS-04.
1.50
1.50
10.3
1391
3.35
100
1.50
3.30
1MD51061BD..4BA1
DNGW-100LR-04.
2.20
2.20
14.9
1410
4.75
100
2.20
4.65
1MD51081BD..4BA1
DNGW-100LS-04.
3.00
3.00
20.3
1411
6.30
100
3.00
6.20
1MD51131BD..4BA1
DNGW-112MS-04.
4.00
4.10
26.9
1455
8.40
100
4.10
8.40
1MD51311BD..4BA1
DNGW-132SR-04.
5.50
5.50
36.9
1423
11.6
100
5.50
11.3
1MD51331BD..4BA1
DNGW-132MS-04.
7.50
7.50
50
1432
15.1
100
7.50
14.7
1MD51631BD..4BA1
DNGW-160MR-04.
11.0
11.0
74
1419
21.5
100
11.0
21.0
1MD51661BD..4BA1
DNGW-160LS-04.
15.0
15.0
100
1432
29.0
100
15.0
28.0
1MD51831BD..4BA1
DNGW-180MR-04.
18.5
19.0
124
1463
35.5
100
19.0
35.5
1MD51861BD..4BA1
DNGW-180LS-04.
22.0
22.5
148
1452
42.5
100
22.5
42.0
1MD52061BD..4BA1
DNGW-200LS-04.
30.0
30.5
201
1449
57.0
100
30.5
57.0
1MD52201BD..4BA1
DNGW-225SR-04.
37.0
38.0
248
1463
67.0
87
38.0
67.0
1MD52231BD..4BA1
DNGW-225MS-04.
45.0
46.0
300
1464
82.0
87
46.0
82.0
1MD52531BD..4BA1
DNGW-250MM-04.
55.0
56.5
366
1474
103
80
56.5
102
1MD52801BD..4BA1
DNGW-280SL-04.
75.0
77.0
497
1479
136
75
77.0
136
1MD52831BD..4BA1
DNGW-280MM-04.
90.0
92.0
596
1474
163
75
92.0
162
1MD53111BD..4BA1
DNGW-315SL-04.
110
113
726
1486
200
65
113
200
1MD53131BD..4BA1
DNGW-315ML-04.
132
135
871
1480
240
65
135
235
1MD53151BD..4BA1
DNGW-315MN-04.
160
164
1056
1483
285
65
164
285
1MD53161BD..4BA1
DNGW-315LL-04.
200
205
1320
1483
360
65
205
355
1MD53171BD..4BA1
DNGW-315LM-04.
250
231
1488
1482
410
65
231
410
1MD53531BD..4BA1
DNGW-355MR-04.
315
292
1874
1488
520
60
292
520
1MD53551BD..4BA1
DNGW-355MS-04.
360
333
2142
1485
600
60
333
600
1MD53571BD..4BA1
DNGW-355MT-04.
460
426
2737
1486
750
60
426
750
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016