SIEMENS
1/77
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
“Converter operation”
(Frequency – control range) – rating plate: Operational torque limits acc. to IEC 60079-0 [29.15]
Setting range 1 : 10
Setting range 1 : 3
Setting range 10 : 17
2)
T
= constant
T
= constant
Any load characteristic
Constant flux
Constant flux
Constant flux
5 ... 50 Hz
16
2
/
3
... 50 Hz
50 ... 87 Hz
5 Hz
Power
50 Hz
Power
5 … 50 Hz
Torque
Current
16
2
/
3
Hz
Power
50 Hz
Power
16
2
/
3
… 50 Hz
Power
Torque
Current
Torque
Current
P
5 Hz
P
50 Hz
T
I
VSD
P
16 2/3 Hz
P
50 Hz
T
I
VSD
P
T
I
VSD
kW
kW
Nm
kW
kW
Nm
A
kW
Nm
0.01
0.14
0.98
0.70
0.06
0.20
1.34
0.74
0.36
1.36
1.29
0.01
0.21
1.44
0.88
0.08
0.29
2.00
0.94
0.50
2.05
1.64
0.02
0.33
2.15
1.13
0.13
0.44
2.91
1.24
0.75
2.95
2.15
0.03
0.45
2.93
1.41
0.18
0.60
3.97
1.59
1.05
4.02
2.75
0.04
0.65
4.30
1.95
0.27
0.85
5.90
2.20
1.50
6.00
3.90
0.06
0.85
5.90
2.55
0.37
1.20
8.00
2.90
2.10
8.10
5.10
0.11
1.30
8.60
3.35
0.55
1.70
11.6
3.95
3.10
11.70
6.90
0.15
1.80
11.8
4.35
0.75
2.40
15.8
5.20
4.20
15.90
9.10
0.20
2.40
15.7
6.20
1.00
3.20
21.0
7.20
5.70
21.10
12.50
0.29
3.30
21.6
8.10
1.40
4.40
28.8
9.60
7.80
29.00
16.80
0.39
4.50
29.4
10.1
1.90
6.00
39.2
12.3
10.60
39.50
21.50
0.55
6.50
43.1
14.6
2.80
8.50
57.0
17.6
15.60
57.80
30.50
0.80
9.00
59.0
19.5
3.90
12.0
78.0
23.5
21.20
78.50
41.00
0.95
11.0
73.0
23.5
4.80
14.5
97.0
29.0
26.30
97.50
51.00
1.10
13.0
86.0
28.5
5.50
17.5
115
35.0
31.30
115.90
61.00
1.60
18.0
118
38.0
7.50
24.0
157
46.5
42.60
157.50
81.00
2.10
24.0
156
45.0
9.50
30.0
197
55.0
–
–
–
2.60
29.5
190
56.0
11.5
36.5
238
67.0
–
–
–
3.30
36.0
232
71.0
14.5
45.0
291
84.0
–
–
–
4.60
49.0
317
92.0
20.0
61.5
396
111
–
–
–
5.50
59.0
380
112
24.0
73.5
474
134
–
–
–
6.50
72.5
464
138
29.0
90.0
579
165
–
–
–
8.00
87.0
557
161
35.0
108
694
194
–
–
–
10.0
105
675
196
43.0
131
842
235
–
–
–
12.5
132
844
245
54.0
164
1052
295
–
–
–
15.5
164
1055
310
67.0
205
1317
370
–
–
–
19.5
207
1330
395
84.0
258
1659
470
–
–
–
22.0
237
1520
450
96.0
295
1896
540
–
–
–
28.0
303
1942
560
124
378
2422
680
–
–
–
2)
Optional voltage with
9
at the 11th position of the Article No. and order
code
L1P
: 230/400 V
/Y, 50 Hz; 400 V
87Hz (operating values at 87 Hz
and motor in
circuit).
© Siemens AG 2016