SIEMENS
1/76
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
4-pole: 1500 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 130 (B)
1MD50701BD..4BA1
DNGW-071BR-04.
0.25
0.23
1.56
1408
0.78
100
0.23
0.77
1MD50711BD..4BA1
DNGW-071BS-04.
0.37
0.34
2.36
1376
0.99
100
0.34
0.99
1MD50801BD..4BA1
DNGW-080BR-04.
0.55
0.50
3.38
1413
1.32
100
0.50
1.31
1MD50811BD..4BA1
DNGW-080BS-04.
0.75
0.65
4.61
1346
1.71
100
0.65
1.65
1MD50951BD..4BA1
DNGW-090LR-04.
1.10
1.00
6.80
1404
2.40
100
1.00
2.35
1MD50981BD..4BA1
DNGW-090LS-04.
1.50
1.30
9.30
1335
3.15
100
1.30
3.05
1MD51061BD..4BA1
DNGW-100LR-04.
2.20
2.00
13.4
1425
4.40
100
2.00
4.35
1MD51081BD..4BA1
DNGW-100LS-04.
3.00
2.70
18.3
1409
5.80
100
2.70
5.70
1MD51131BD..4BA1
DNGW-112MS-04.
4.00
3.70
24.3
1454
7.80
100
3.70
7.80
1MD51311BD..4BA1
DNGW-132SR-04.
5.50
5.10
33.2
1467
10.7
100
5.10
10.7
1MD51331BD..4BA1
DNGW-132MS-04.
7.50
6.50
45.3
1370
13.8
100
6.50
13.1
1MD51631BD..4BA1
DNGW-160MR-04.
11.0
10.0
66.0
1447
19.6
100
10.0
19.3
1MD51661BD..4BA1
DNGW-160LS-04.
15.0
13.5
90.0
1432
26.5
100
13.5
26.0
1MD51831BD..4BA1
DNGW-180MR-04.
18.5
17.0
112
1449
32.5
100
17.0
32.5
1MD51861BD..4BA1
DNGW-180LS-04.
22.0
20.0
133
1436
39.0
100
20.0
38.0
1MD52061BD..4BA1
DNGW-200LS-04.
30.0
27.5
181
1451
52.0
100
27.5
52.0
1MD52201BD..4BA1
DNGW-225SR-04.
37.0
34.0
223
1456
61.0
87
34.0
61.0
1MD52231BD..4BA1
DNGW-225MS-04.
45.0
41.5
270
1468
75.0
87
41.5
75.0
1MD52531BD..4BA1
DNGW-250MM-04.
55.0
51.0
329
1480
94.0
80
51.0
94.0
1MD52801BD..4BA1
DNGW-280SL-04.
75.0
69.5
447
1485
124
75
69.5
124
1MD52831BD..4BA1
DNGW-280MM-04.
90.0
83.0
536
1479
148
75
83.0
148
1MD53111BD..4BA1
DNGW-315SL-04.
110
102
654
1489
183
65
102
183
1MD53131BD..4BA1
DNGW-315ML-04.
132
122
784
1486
215
65
122
215
1MD53151BD..4BA1
DNGW-315MN-04.
160
148
951
1486
260
65
148
260
1MD53161BD..4BA1
DNGW-315LL-04.
200
185
1188
1487
325
65
185
325
1MD53171BD..4BA1
DNGW-315LM-04.
250
231
1488
1482
410
65
231
410
1MD53531BD..4BA1
DNGW-355MR-04.
315
292
1874
1488
520
60
292
520
1MD53551BD..4BA1
DNGW-355MS-04.
360
333
2142
1485
600
60
333
600
1MD53571BD..4BA1
DNGW-355MT-04.
460
426
2737
1486
750
60
426
750
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016