SIEMENS
1/74
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max
)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
2-pole: 3000 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 155 (F)
– can be ordered with additional
1MD50701BD..4AA1
DNGW-071BR-02.
0.37
0.38
1.27
2857
0.93
100
0.38
0.92
1MD50711BD..4AA1
DNGW-071BS-02.
0.55
0.55
1.90
2764
1.36
100
0.55
1.34
1MD50801BD..4AA1
DNGW-080BR-02.
0.75
0.75
2.63
2723
1.70
85
0.75
1.67
1MD50811BD..4AA1
DNGW-080BS-02.
1.10
1.10
3.82
2750
2.45
100
1.10
2.40
1MD50951BD..4AA1
DNGW-090LR-02.
1.50
1.50
5.10
2809
3.25
100
1.50
2.90
1MD50981BD..4AA1
DNGW-090LS-02.
2.20
2.20
7.50
2801
4.60
100
2.20
4.50
1MD51061BD..4AA1
DNGW-100LS-02.
3.00
3.00
10.2
2809
6.20
100
3.00
6.10
1MD51131BD..4AA1
DNGW-112MS-02.
4.00
4.10
13.3
2944
8.00
100
4.10
8.00
1MD51311BD..4AA1
DNGW-132SR-02.
5.50
5.50
18.3
2870
10.8
90
5.50
10.5
1MD51321BD..4AA1
DNGW-132SS-02.
7.50
7.50
25.0
2865
14.5
90
7.50
14.1
1MD51631BD..4AA1
DNGW-160MR-02.
11.0
11.0
36.6
2870
21.0
80
11.0
20.5
1MD51651BD..4AA1
DNGW-160MS-02.
15.0
15.0
49.9
2871
28.0
80
15.0
27.0
1MD51661BD..4AA1
DNGW-160LS-02.
18.5
19.0
62.0
2926
34.5
80
19.0
34.0
1MD51831BD..4AA1
DNGW-180MS-02.
22.0
22.5
74.0
2904
41.0
76
22.5
41.0
1MD52061BD..4AA1
DNGW-200LR-02.
30.0
30.5
100
2913
56.0
75
30.5
55.0
1MD52081BD..4AA1
DNGW-200LS-02.
37.0
38.0
123
2950
67.0
75
38.0
67.0
1MD52231BD..4AA1
DNGW-225MS-02.
45.0
46.0
149
2948
82.0
75
46.0
81.0
1MD52531BD..4AA1
DNGW-250MM-02.
55.0
56.5
182
2964
98.0
65
56.5
98.0
1MD52801BD..4AA1
DNGW-280SL-02.
75.0
77.0
248
2965
136
60
77.0
136
1MD52831BD..4AA1
DNGW-280MM-02.
90.0
92.0
298
2948
161
60
92.0
160
1MD53111BD..4AA1
DNGW-315SL-02.
110
113
363
2973
192
60
113
192
1MD53131BD..4AA1
DNGW-315ML-02.
132
135
435
2964
230
60
135
225
1MD53151BD..4AA1
DNGW-315MN-02.
160
164
528
2966
270
60
164
270
1MD53161BD..4AA1
DNGW-315LL-02.
200
205
660
2966
340
60
205
340
1MD53181BD..4AA1
DNGW-315LN-02.
250
231
741
2977
385
60
231
385
1MD53531BD..4AA1
DNGW-355MR-02.
315
292
934
2985
500
60
292
500
1MD53551BD..4AA1
DNGW-355MS-02.
360
333
1068
2977
570
60
333
570
1MD53571BD..4AA1
DNGW-355MT-02.
460
426
1364
2982
710
60
426
710
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016