SIEMENS
1/72
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
■
Overview
(continued)
SIMOTICS XP 1MD5 (Ex d (e)) motors – Power tables for converter operation
Type
Motor type
Line
operation
Operating values for converter operation – rated data for rating plate
Setting range 1 : 10
P
VSD
= constant
1)
T
~
n
2
Any load characteristic
Constant flux
Field weakening
5 ... 50 Hz
50 Hz ...
f
max
Rated power
Power
Torque
Speed
Current
Max.
frequency
Power
Current
(values at 400 V, 50 Hz)
(at 400 V
f
max)
P
rated
P
VSD
T
VSD
n
asyn_VSD
I
VSD
f
max
P
VSD
I
VSD
kW
kW
Nm
rpm
A
Hz
kW
A
Cooling: self-ventilated (IC411)
Efficiency: High Efficiency IE2
Ambient temperature: 40 °C, installation altitude: 1000 m
2-pole: 3000 rpm at 50 Hz
Insulation: Thermal class 155 (F) – VSD utilization of the winding in accordance with thermal class 130 (B)
1MD50701BD..4AA1
DNGW-071BR-02.
0.37
0.34
1.15
2823
0.88
100
0.34
0.88
1MD50711BD..4AA1
DNGW-071BS-02.
0.55
0.50
1.71
2792
1.29
100
0.50
1.27
1MD50801BD..4AA1
DNGW-080BR-02.
0.75
0.65
2.37
2619
1.58
95
0.65
1.50
1MD50811BD..4AA1
DNGW-080BS-02.
1.10
1.00
3.43
2784
2.30
100
1.00
2.25
1MD50951BD..4AA1
DNGW-090LR-02.
1.50
1.30
4.60
2699
3.00
100
1.30
2.90
1MD50981BD..4AA1
DNGW-090LS-02.
2.20
2.00
6.70
2851
4.30
100
2.00
4.25
1MD51061BD..4AA1
DNGW-100LS-02.
3.00
2.70
9.10
2833
5.70
100
2.70
5.60
1MD51131BD..4AA1
DNGW-112MS-02.
4.00
3.70
12.0
2944
7.30
100
3.70
7.30
1MD51311BD..4AA1
DNGW-132SR-02.
5.50
5.10
16.5
2952
9.80
90
5.10
9.90
1MD51321BD..4AA1
DNGW-132SS-02.
7.50
6.50
22.5
2759
13.3
90
6.50
12.6
1MD51631BD..4AA1
DNGW-160MR-02.
11.0
10.0
33.0
2894
19.2
80
10.0
18.9
1MD51651BD..4AA1
DNGW-160MS-02.
15.0
13.5
44.9
2871
25.5
80
13.5
25.0
1MD51661BD..4AA1
DNGW-160LS-02.
18.5
17.0
55.0
2952
31.5
80
17.0
31.0
1MD51831BD..4AA1
DNGW-180MS-02.
22.0
20.0
66.0
2894
37.5
76
20.0
37.0
1MD52061BD..4AA1
DNGW-200LR-02.
30.0
27.5
90.0
2918
51.0
75
27.5
50.0
1MD52081BD..4AA1
DNGW-200LS-02.
37.0
34.0
111
2925
61.0
75
34.0
61.0
1MD52231BD..4AA1
DNGW-225MS-02.
45.0
41.5
134
2957
74.0
75
41.5
74.0
1MD52531BD..4AA1
DNGW-250MM-02.
55.0
51.0
164
2970
89.0
65
51.0
89.0
1MD52801BD..4AA1
DNGW-280SL-02.
75.0
69.5
223
2976
124
60
69.5
124
1MD52831BD..4AA1
DNGW-280MM-02.
90.0
83.0
268
2957
146
60
83.0
146
1MD53111BD..4AA1
DNGW-315SL-02.
110
102
327
2979
174
60
102
174
1MD53131BD..4AA1
DNGW-315ML-02.
132
122
392
2972
205
60
122
205
1MD53151BD..4AA1
DNGW-315MN-02.
160
148
475
2975
245
60
148
245
1MD53161BD..4AA1
DNGW-315LL-02.
200
185
594
2974
305
60
185
305
1MD53181BD..4AA1
DNGW-315LN-02.
250
231
741
2977
385
60
231
385
1MD53531BD..4AA1
DNGW-355MR-02.
315
292
934
2985
500
60
292
500
1MD53551BD..4AA1
DNGW-355MS-02.
360
333
1068
2977
570
60
333
570
1MD53571BD..4AA1
DNGW-355MT-02.
460
426
1364
2982
710
60
426
710
1)
The reduced torque in the field-weakening range shall be calculated
as follows:
T
[Nm] = 9550 ·
P
VSD
[kW]/
n
[rpm]
© Siemens AG 2016