Operating values at rated power
Motor type
Article No.
P
rated,
50 Hz
Frame
size
n
rated,
50 Hz
T
rated,
50 Hz
IE
class
rated.
50 Hz,
4/4
rated.
50 Hz,
3/4
rated.
50 Hz,
2/4
cos
rat.,
50 Hz,
4/4
I
rated;
50 Hz,
400 V
I
rated,
50 Hz,
500 V
I
rated,
50 Hz,
690 V
T
LR
/
T
rat.
I
LR
/
I
rat.
T
B/
T
rat.
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
A
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: High Efficiency IE2 in accordance with IEC 60034-30-1
•
Insulation: Thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130
(temperature class B), S1-100 %
12-pole: 500 rpm at 50 Hz
LOHER CHEMSTAR
on request
LOHER VARIO
160
355 L
493
3097
1)
94.1 94.3 93.8 0.78
313
250
181
0.95 4.6
2.1
ANSA-355LC-12
1PS0357-
■
BH
■
■
-0FA0
2350 17
180
355 L
494
3481
1)
94.3 94.5 93.9 0.77
355
285
205
1.0
4.7
2.15
ANSA-355LD-12
1PS0358-
■
BH
■
■
-0FA0
2400 19
190
355 L
494
3672
1)
94.5 94.7 94.3 0.77
375
300
218
0.95 4.6
2.2
ANSA-355LX-12
1PS0358-
■
BJ
■
■
-0FA0
2550 18.5
200
400 L
494
3861
1)
94.9 95.1 94.7 0.78
390
310
225
0.95 4.6
2.05
ANSA-400LL-12
1PS0404-
■
BJ
■
■
-0FA0
2800 26.5
225
400 L
495
4341
1)
95.1 95.3 94.9 0.79
430
345
250
1.0
4.7
2.15
ANSA-400LN-12
1PS0405-
■
BJ
■
■
-0FA0
3100 32
250
400 L
495
4824
1)
95.2 95.4 95.0 0.78
485
390
282
1.0
4.6
2.1
ANSA-400LN-12
1PS0407-
■
BJ
■
■
-0FA0
3100 32
280
400 L
495
5402
1)
95.2 95.4 95.0 0.78
545
435
315
0.95 4.8
2.2
ANSA-400LX-12
1PS0408-
■
BJ
■
■
-0FA0
3300 35
315
450 L
495
6075
1)
95.5 95.7 95.3 0.78
610
490
355
0.9
4.5
1.95
ANSA-450LL-12
1PS0454-
■
BJ
■
■
-0FA0
4100 42
355
450 L
495
6842
1)
95.6 95.8 95.4 0.78
690
550
400
0.9
4.6
2.0
ANSA-450LN-12
1PS0455-
■
BJ
■
■
-0FA0
4400 50
400
450 L
495
7709
1)
95.7 95.9 95.4 0.78
785
630
455
0.95 4.6
2.0
ANSA-450LN-12
1PS0457-
■
BJ
■
■
-0FA0
4400 50
420
450 L
495
8095
1)
95.7 95.9 95.4 0.78
810
650
470
0.95 4.7
2.05
ANSA-450LX-12
1PS0458-
■
BJ
■
■
-0FA0
4600 55
450
500 L
496
8662
1)
95.8 95.8 95.2 0.80
845
675
490
0.9
4.8
2.05
ANSA-500LL-12
1PS0504-
■
BJ
■
■
-0FA0
5400 82
500
500 L
496
9617
1)
95.8 95.8 95.1 0.79
950
760
550
0.95 5.1
2.2
ANSA-500LN-12
1PS0505-
■
BJ
■
■
-0FA0
6100 98
560
500 L
496
10779
1)
95.9 96.0 95.3 0.80
1055 840
610
0.9
4.9
2.1
ANSA-500LN-12
1PS0507-
■
BJ
■
■
-0FA0
6100 98
600
500 L
496
11546
1)
96.0 96.1 95.5 0.80
–
905
655
0.9
5.1
2.15
ANSA-500LX-12
1PS0508-
■
BJ
■
■
-0FA0
6350 108
Operating modes
Frame size
Order code
Line operation
355 … 450
0
–
Converter operation, standard insulation
355 … 450
1
–
Converter operation with special insulation (derating approx. 5 %)
2)
355 … 500
2
–
Line operation, pre-formed coil
450 … 500
3
–
Converter operation, pre-formed coil
450 … 500
4
–
Voltages
Frame size
Order code
690 V
, 50 Hz
355 … 500
0
–
500 V
, 50 Hz
355 … 450
5
–
400 V/690 V, 50 Hz
355 … 400
6
–
690 VY, 50 Hz
355 … 400
8
–
For other voltages,
see Page 3/27
355 … 500
9
…
Types of construction
Frame size
Order code
IM B3
355 … 500
0
–
IM V1/cover
355 … 450
4
–
IM B35
355 … 500
6
–
For other types of construction,
see from Page 1/29 and 3/28
355 … 500
9
…
1)
Outside the IE code classification according to IEC 60034-30-1.
2)
Insulation, 2.15 kV IEC/TS 60035-25:2007 curve B.
© Siemens AG 2016