SIEMENS
3/11
Siemens D 83.1 · 2016
3
Motors without Explosion Protection
LOHER CHEMSTAR and VARIO 1PS0 motor series
Motors with High Efficiency IE2 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rated,
50 Hz
Frame
size
n
rated,
50 Hz
T
rated,
50 Hz
IE
class
rated.
50 Hz,
4/4
rated.
50 Hz,
3/4
rated.
50 Hz,
2/4
cos
rat.,
50 Hz,
4/4
I
rated;
50 Hz,
400 V
I
rated,
50 Hz,
500 V
I
rated,
50 Hz,
690 V
T
LR
/
T
rat.
I
LR
/
I
rat.
T
B/
T
rat.
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
A
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: High Efficiency IE2 in accordance with IEC 60034-30-1
•
Insulation: Thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130
(temperature class B), S1-100 %
10-pole: 600 rpm at 50 Hz
LOHER CHEMSTAR
on request
LOHER VARIO
180
355 L
594
2889
1)
94.6 94.7 94.0 0.81
338
271
196
1.05 5.3
2.15
ANSA-355LC-10
1PS0357-
■
BH
■
■
-0EA0
2350 16.5
200
355 L
594
3211
1)
94.6 94.8 94.1 0.81
376
300
218
1.05 5.1
2.05
ANSA-355LD-10
1PS0358-
■
BH
■
■
-0EA0
2400 18
225
355 L
593
3620
1)
95.2 95.5 95.1 0.80
425
340
245
1.1
4.8
2.15
ANSA-355LX-10
1PS0358-
■
BJ
■
■
-0EA0
2550 19
250
400 L
594
4014
1)
95.4 95.7 95.2 0.80
475
380
275
0.95 4.7
2.05
ANSA-400LL-10
1PS0404-
■
BJ
■
■
-0EA0
2800 27
280
400 L
595
4495
1)
95.6 95.8 95.3 0.81
520
415
300
0.95 4.7
2.05
ANSA-400LN-10
1PS0405-
■
BJ
■
■
-0EA0
3100 32
315
400 L
595
5058
1)
95.6 95.8 95.4 0.80
595
475
345
0.95 4.7
2.05
ANSA-400LN-10
1PS0407-
■
BJ
■
■
-0EA0
3100 32
355
400 L
595
5700
1)
95.8 96.0 95.6 0.80
665
530
385
0.95 4.8
2.1
ANSA-400LX-10
1PS0408-
■
BJ
■
■
-0EA0
3300 35
400
450 L
595
6418
1)
96.0 96.1 95.5 0.80
750
600
435
1.0
4.9
2.1
ANSA-450LL-10
1PS0454-
■
BJ
■
■
-0EA0
4100 42
450
450 L
595
7221
1)
96.1 96.2 95.6 0.81
835
670
485
0.95 4.8
2.05
ANSA-450LN-10
1PS0455-
■
BJ
■
■
-0EA0
4400 50
500
450 L
595
8020
1)
96.2 96.3 95.7 0.80
940
750
545
0.95 5.0
2.15
ANSA-450LN-10
1PS0457-
■
BJ
■
■
-0EA0
4400 50
520
450 L
595
8336
1)
96.2 96.2 95.6 0.79
985
785
570
1.0
5.1
2.2
ANSA-450LX-10
1PS0458-
■
BJ
■
■
-0EA0
4700 55
560
500 L
596
8965
1)
96.1 96.1 95.3 0.80
1050 840
610
0.85 5.3
2.35
ANSA-500LL-10
1PS0504-
■
BJ
■
■
-0EA0
5400 82
630
500 L
596
10082
1)
96.2 96.2 95.4 0.80
1180 945
685
0.9
5.3
2.4
ANSA-500LN-10
1PS0505-
■
BJ
■
■
-0EA0
6100 98
670
500 L
597
10719
1)
96.3 96.2 95.4 0.80
1260 1005 730
0.95 5.5
2.45
ANSA-500LN-10
1PS0507-
■
BJ
■
■
-0EA0
6100 98
750
500 L
597
11998
1)
96.4 96.3 95.5 0.79
–
–
820
0.95 5.5
2.45
ANSA-500LX-10
1PS0508-
■
BJ
■
■
-0EA0
6500 108
Operating modes
Frame size
Order code
Line operation
355 … 450
0
–
Converter operation, standard insulation
355 … 450
1
–
Converter operation with special insulation (derating approx. 5 %)
2)
355 … 500
2
–
Line operation, pre-formed coil
500
3
–
Converter operation, pre-formed coil
500
4
–
Voltages
Frame size
Order code
690 V
, 50 Hz
355 … 500
0
–
500 V
, 50 Hz
355 … 450
5
–
400 V/690 V, 50 Hz
355 … 400
6
–
690 VY, 50 Hz
355 … 400
8
–
For other voltages,
see Page 3/27
355 … 500
9
…
Types of construction
Frame size
Order code
IM B3
355 … 500
0
–
IM V1/cover
355 … 450
4
–
IM B35
355 … 500
6
–
For other types of construction,
see from Page 1/29 and 3/28
355 … 500
9
…
1)
Outside the IE code classification according to IEC 60034-30-1.
2)
Insulation, 2.15 kV IEC/TS 60035-25:2007 curve B.
© Siemens AG 2016