SIEMENS
2/106
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS1 motor series
Motors with Premium Efficiency IE3 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rat.,
50 Hz
Frame
size
n
rated,
50 Hz
T
rated
,
50 Hz
IE
class
rated,
50 Hz,
4/4
rated,
50 Hz,
3/4
rated,
50 Hz,
2/4
cos
rat.,
50 Hz,
4/4
I
rated,
50 Hz,
400 V
I
rated,
50 Hz,
500 V
I
rated,
50 Hz,
690 V
T
LR
/
T
rat.
I
LR
/
I
rat.
T
B
/
T
rat.
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
A
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: Premium Efficiency IE3 according to IEC 60034-30-1
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Non sparking" in accordance with EN 60079-15; 2010: II 3G Ex nA IIC T3 Gc
6-pole: 1000 rpm at 50 Hz
LOHER CHEMSTAR
0.25
71 B
885
2.70
IE3
72.7 73.0 69.0 0.70
0.71 0.57 0.41 2.6
3.2
2.6
ANGK-071BT-06
1PS1071-
■
BD
■
■
-3CH4
30
0.0015
0.37
80 B
940
3.76
IE3
74.0 74.1 70.1 0.66
1.09 0.87 0.63 2.3
4.2
2.7
ANGK-080BS-06
1PS1080-
■
BD
■
■
-3CH4
31
0.002
0.55
80 B
935
5.60
IE3
77.2 77.0 73.9 0.67
1.53 1.23 0.89 2.5
4.5
2.8
ANGK-080BT-06
1PS1081-
■
BD
■
■
-3CH4
32
0.003
0.75
90 L
945
7.60
IE3
78.9 80.0 78.8 0.70
1.96 1.57 1.14 2.2
4.6
2.6
ANGK-090LS-06
1PS1095-
■
BD
■
■
-3CH4
36
0.004
1.1
100 L
975
10.8
IE3
81.0 81.0 79.0 0.71
2.75 2.20 1.60 2.2
5.6
2.9
ANGK-100LT-06
1PS1105-
■
BD
■
■
-3CH4
61
0.014
1.5
112 M
975
14.7
IE3
82.5 82.8 81.2 0.76
3.45 2.75 2.00 2.0
5.7
2.8
ANGK-112MT-06
1PS1112-
■
BD
■
■
-3CH4
69
0.017
2.2
132 S
980
21.4
IE3
88.5 89.0 88.5 0.76
4.70 3.80 2.75 2.0
6.7
3.1
ANGK-132SR-06
1PS1130-
■
BD
■
■
-3CH4
103
0.037
3
132 S
980
29.2
IE3
88.5 89.0 88.5 0.76
6.40 5.20 3.75 2.0
6.3
3.0
ANGK-132SS-06
1PS1131-
■
BD
■
■
-3CH4
105
0.037
4
132 M
975
39.2
IE3
88.5 89.3 89.0 0.76
8.60 6.90 5.00 2.0
6.1
2.8
ANGK-132MS-06
1PS1133-
■
BD
■
■
-3CH4
105
0.037
5.5
132 M
975
53.9
IE3
89.8 90.9 90.9 0.76
11.6 9.30 6.70 2.0
6.3
2.9
ANGK-132MT-06
1PS1135-
■
BD
■
■
-3CH4
112
0.046
7.5
160 M
980
73.1
IE3
89.1 89.8 89.2 0.76
16.0 12.8 9.30 2.0
5.1
2.3
ANGK-160MS-06
1PS1163-
■
BD
■
■
-3CH4
194
0.098
11
160 L
975
107.7 IE3
90.3 91.1 90.7 0.77
23.0 18.3 13.2 2.0
5.1
2.4
ANGK-160LT-06
1PS1166-
■
BD
■
■
-3CH4
213
0.12
15
180 L
975
146.9 IE3
91.5 92.5 92.3 0.80
29.5 23.5 17.1 2.3
5.9
2.8
ANGK-180LT-06
1PS1186-
■
BD
■
■
-3CH4
240
0.19
18.5
200 L
978
180.6 IE3
91.9 92.7 92.7 0.79
37.0 29.5 21.5 2.5
5.6
2.6
ANGK-200LS-06
1PS1206-
■
BD
■
■
-3CH4
314
0.28
22
200 L
978
215
IE3
92.5 93.3 93.5 0.79
43.5 35.0 25.0 2.5
5.6
2.6
ANGK-200LT-06
1PS1208-
■
BD
■
■
-3CH4
328
0.32
30
225 M
982
292
IE3
93.3 94.0 94.0 0.83
56.0 44.5 32.5 2.6
6.6
3.0
ANGK-225MT-06
1PS1223-
■
BD
■
■
-3CH4
469
0.67
37
250 M
985
359
IE3
93.3 94.0 94.0 0.85
67.0 54.0 39.0 2.7
7.0
2.9
ANGK-250MN-06
1PS1253-
■
BD
■
■
-3CH4
520
1.0
45
280 S
988
435
IE3
93.7 94.3 94.2 0.85
82.0 65.0 47.5 3.0
6.8
2.8
ANGK-280SM-06
1PS1280-
■
BD
■
■
-3CH4
660
1.4
55
280 M
988
532
IE3
94.1 94.6 94.4 0.85
99.0 79.0 58.0 3.2
7.2
3.0
ANGK-280MN-06
1PS1283-
■
BD
■
■
-3CH4
695
1.6
75
315 S
990
723
IE3
94.6 94.9 94.4 0.84
136
109
79.0 2.6
7.5
3.1
ANGK-315SL-06
1PS1311-
■
BD
■
■
-3CH4
945
2.6
90
315 M
991
867
IE3
94.9 95.2 94.9 0.85
161
129
93.0 2.5
6.7
2.8
ANGK-315ML-06
1PS1313-
■
BD
■
■
-3CH4
1015 3.1
110
315 M
991
1060
IE3
95.1 95.5 95.3 0.84
199
159
115
2.8
7.2
3.0
ANGK-315MM-06
1PS1314-
■
BD
■
■
-3CH4
1115 3.9
132
315 M
991
1272
IE3
95.4 95.9 95.8 0.84
240
190
138
2.7
7.2
3.0
ANGK-315LK-06
1PS1315-
■
BD
■
■
-3CH4
1315 4.4
160
315 L
991
1542
IE3
95.6 95.8 95.4 0.83
290
235
169
3.3
7.7
3.5
ANGK-315LL-06
1PS1316-
■
BD
■
■
-3CH4
1355 4.6
200
315 L
990
1929
IE3
95.0 95.3 94.9 0.83
365
295
210
2.8
7.5
3.3
ANGK-315LM-06
1PS1317-
■
BD
■
■
-3CH4
1600 7.6
Operating modes
Frame size
Order code
Line operation
71 ... 315
0
–
Converter operation, standard insulation
1)
71 ... 315
1
–
Voltages
Frame size
Order code
230 V/400 V, 50 Hz
71 ... 280
1
–
500 VY, 50 Hz
71 ... 315
2)
3
–
400 V/690 V, 50 Hz
71 ... 315
6
–
690 VY, 50 Hz
71 ... 315
8
–
For other voltages,
see Page 2/110
71 ... 315
9
…
Types of construction
Frame size
Order code
IM B3
71 ... 315
0
–
IM B5
71 ... 315
1
–
IM B34
71 ... 112
2
–
IM B14
71 ... 112
3
–
IM V1/cover
71 ... 315
4
–
IM B35
71 ... 315
6
–
For other types of construction,
see from Page 1/29 and 2/111
71 ... 315
9
…
1)
Can only be ordered with additional identification code
-Z
and order code
M73
.
2)
Up to 200 kW.
© Siemens AG 2016