SIEMENS
2/102
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS1 motor series
Motors with High Efficiency IE2 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rated,
60 Hz
Frame
size
n
rated,
60 Hz
T
rated,
60 Hz
IE
class
rated,
60 Hz,
4/4
rated,
60 Hz,
3/4
rated,
60 Hz,
2/4
cos
rat.,
60 Hz,
4/4
I
rated,
60 Hz,
460 V
T
LR
/
T
rated
I
LR
/
I
rated
T
B
/
T
rated
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: High Efficiency IE2 in accordance with IEC 60034-30-1
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Non sparking" in accordance with EN 60079-15; 2010: II 3G Ex nA IIC T3 Gc
4-pole: 1800 rpm at 60 Hz
LOHER CHEMSTAR
0.29
71 B
1695
1.63
–
70.0
70.0
66.0
0.69
0.75
2.4
4.1
2.6
ANGK-071BR-04
1PS1070-
■
BD
■
■
-3BA4
25
0.0007
0.43
71 B
1680
2.44
IE2
77.4
77.1
74.1
0.72
0.97
2.4
4.0
2.4
ANGK-071BS-04
1PS1071-
■
BD
■
■
-3BA4
26
0.0009
0.63
80 B
1740
3.46
IE2
81.3
81.2
79.0
0.76
1.28
2.3
6.0
3.2
ANGK-080BR-04
1PS1080-
■
BD
■
■
-3BA4
28
0.0017
0.86
80 B
1740
4.72
IE2
82.5
82.5
81.5
0.77
1.70
2.2
6.2
3.3
ANGK-080BS-04
1PS1081-
■
BD
■
■
-3BA4
29
0.0021
1.27
90 L
1725
7.00
IE2
84.0
84.0
83.0
0.78
2.45
2.3
6.1
3.0
ANGK-090LR-04
1PS1095-
■
BD
■
■
-3BA4
33
0.0028
1.75
90 L
1730
9.70
IE2
85.0
85.9
84.9
0.80
3.25
2.6
6.4
3.4
ANGK-090LS-04
1PS1098-
■
BD
■
■
-3BA4
35
0.0036
2.55
100 L
1755
13.9
IE2
87.5
87.5
86.5
0.82
4.45
2.1
7.3
3.3
ANGK-100LR-04
1PS1106-
■
BD
■
■
-3BA4
53
0.0086
3.45
100 L
1755
18.8
IE2
88.0
88.9
88.3
0.84
5.90
2.0
7.5
3.1
ANGK-100LS-04
1PS1108-
■
BD
■
■
-3BA4
56
0.011
4.55
112 M
1760
24.7
IE2
88.6
89.2
88.6
0.82
7.90
2.4
7.5
3.2
ANGK-112MS-04
1PS1113-
■
BD
■
■
-3BA4
64
0.014
6.3
132 S
1765
34.1
IE2
89.9
90.4
89.7
0.81
10.9
2.3
7.3
2.9
ANGK-132SR-04
1PS1131-
■
BD
■
■
-3BA4
93
0.027
8.6
132 M
1765
46.5
IE2
90.1
91.1
91.0
0.84
14.3
2.3
6.6
2.9
ANGK-132MS-04
1PS1133-
■
BD
■
■
-3BA4
99
0.034
12.6
160 M
1770
68.0
IE2
91.3
91.8
91.2
0.85
20.5
2.2
7.0
2.8
ANGK-160MR-04
1PS1163-
■
BD
■
■
-3BA4
169
0.065
17.3
160 L
1775
93.0
IE2
92.4
92.6
92.4
0.86
27.5
2.3
6.5
2.9
ANGK-160LS-04
1PS1166-
■
BD
■
■
-3BA4
182
0.083
21.3
180 M
1765
115
IE2
92.4
93.1
92.9
0.85
34.0
2.5
6.8
3.4
ANGK-180MR-04
1PS1183-
■
BD
■
■
-3BA4
236
0.12
25.3
180 L
1765
137
IE2
92.8
93.4
93.2
0.85
40.5
2.6
7.5
3.4
ANGK-180LS-04
1PS1186-
■
BD
■
■
-3BA4
243
0.13
34.5
200 L
1770
186
IE2
93.8
94.0
93.7
0.85
54.0
2.7
7.2
3.2
ANGK-200LS-04
1PS1206-
■
BD
■
■
-3BA4
320
0.20
40
225 S
1773
215
IE2
93.3
93.8
93.6
0.87
62.0
2.4
7.4
3.0
ANGK-225SR-04
1PS1220-
■
BD
■
■
-3BA4
403
0.42
49.5
225 M
1775
266
IE2
93.6
93.7
93.0
0.87
76.0
2.6
7.2
3.2
ANGK-225MS-04
1PS1223-
■
BD
■
■
-3BA4
425
0.46
63
250 M
1780
338
IE2
94.1
94.4
94.0
0.85
99.0
2.8
6.6
2.9
ANGK-250MM-04
1PS1253-
■
BD
■
■
-3BA4
510
0.75
86
280 S
1785
460
IE2
95.0
95.1
94.8
0.88
129
2.5
6.7
2.8
ANGK-280SL-04
1PS1280-
■
BD
■
■
-3BA4
700
1.3
104
280 M
1785
556
IE2
95.1
95.2
94.7
0.87
158
2.5
7.2
3.1
ANGK-280MM-04
1PS1283-
■
BD
■
■
-3BA4
715
1.4
127
315 S
1788
678
IE2
95.1
95.2
94.5
0.86
195
2.7
7.2
2.9
ANGK-315SL-04
1PS1311-
■
BD
■
■
-3BA4
935
2.0
152
315 M
1788
812
IE2
95.4
95.5
95.0
0.87
230
2.6
7.1
2.8
ANGK-315ML-04
1PS1313-
■
BD
■
■
-3BA4
1000 2.3
184
315 M
1788
983
IE2
95.4
95.5
95.0
0.88
275
2.9
7.2
3.0
ANGK-315MN-04
1PS1315-
■
BD
■
■
-3BA4
1085 2.8
230
315 L
1790
1227
IE2
95.6
95.7
95.1
0.87
345
3.4
7.7
3.1
ANGK-315LL-04
1PS1316-
■
BD
■
■
-3BA4
1320 3.5
280
315 L
1789
1495
IE2
95.8
95.9
95.3
0.87
420
2.7
8.0
2.7
ANGK-315LM-04
1PS1317-
■
BD
■
■
-3BA4
1520 4.2
LOHER VARIO
400
355 L
1791
2133
1)
96.4
96.3
95.5
0.86
–
1.1
6.5
2.30
ANSK-355LC-04
1PS1358-
■
BH
■
■
-3BA0
2300 7.7
450
355 L
1791
2399
1)
96.5
96.4
95.6
0.86
–
1.1
6.5
2.30
ANSK-355LD-04
1PS1350-
■
BH
■
■
-3BA0
2350 8.5
500
355 L
1791
2664
1)
96.6
96.5
95.9
0.86
–
1.05 6.3
2.45
ANSK-355LN-04
1PS1357-
■
BJ
■
■
-3BA0
2400 9.0
560
355 L
1792
2984
1)
96.7
96.6
95.9
0.85
–
1.0
6.5
2.50
ANSK-355LX-04
1PS1358-
■
BJ
■
■
-3BA0
2500 9.5
560
400 L
1791
2984
1)
96.5
96.4
95.6
0.88
–
1.0
6.2
2.55
ANSK-400LL-04
1PS1404-
■
BJ
■
■
-3BA0
2700 13
630
400 L
1791
3357
1)
96.6
96.5
95.8
0.89
–
1.0
6.0
2.45
ANSK-400LN-04
1PS1405-
■
BJ
■
■
-3BA0
2900 15
710
400 L
1791
3784
1)
96.7
96.6
96.0
0.89
–
0.95 5.7
2.30
ANSK-400LN-04
1PS1407-
■
BJ
■
■
-3BA0
2900 15
800
400 L
1792
4263
1)
96.8
96.8
96.1
0.88
–
0.95 6.1
2.45
ANSK-400LX-04
1PS1408-
■
BJ
■
■
-3BA0
3100 17
900
450 L
1793
4792
1)
96.9
96.8
96.1
0.88
–
0.90 6.4
2.55
ANSK-450LL-04
1PS1455-
■
BJ
■
■
-3BA0
3800 24.5
1000
450 L
1793
5324
1)
96.9
96.8
96.2
0.88
980
2)
0.85 6.0
2.40
ANSK-450LN-04
1PS1457-
■
BJ
■
■
-3BA0
4300 29
Operating modes
Frame size
Order code
Line operation
71 ... 450
0
–
Converter operation, standard insulation
3)
71 ... 450
1
–
Converter operation with special insulation (derating approx. 5 %)
3) 4)
160 ... 450
2
–
Line operation, pre-formed coil
450 ... 450
3
–
Converter operation, pre-formed coil
450 ... 450
4
–
Voltages
Frame size
Order code
For other voltages,
see Page 2/110
71 ... 450
9
…
Types of construction
Frame size
Order code
IM B3
71 ... 450
0
–
IM B5
71 ... 315
1
–
IM B34
71 ... 112
2
–
IM B14
71 ... 112
3
–
IM V1/cover
71 ... 450
4
–
IM B35
71 ... 450
6
–
For other types of construction,
see from Page 1/29 and 2/111
71 ... 450
9
…
1)
Outside the IE code classification according to IEC 60034-30-1.
2)
Only possible with 690 V (values apply to 690 V).
3)
Can only be ordered with additional identification code
-Z
and order code
M73
.
4)
Insulation 2.15 kV IEC/TS 60035-25:2007 curve B.
© Siemens AG 2016