SIEMENS
2/101
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS1 motor series
Motors with High Efficiency IE2 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rated,
60 Hz
Frame
size
n
rated,
60 Hz
T
rated,
60 Hz
IE
class
rated,
60 Hz,
4/4
rated,
60 Hz,
3/4
rated,
60 Hz,
2/4
cos
rat.,
60 Hz,
4/4
I
rated,
60 Hz,
460 V
T
LR
/
T
rated
I
LR
/
I
rated
T
B
/
T
rated
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: High Efficiency IE2 in accordance with IEC 60034-30-1
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Non sparking" in accordance with EN 60079-15; 2010: II 3G Ex nA IIC T3 Gc
2-pole: 3000 rpm at 60 Hz
LOHER CHEMSTAR
0.43
71 B
3450
1.19
IE2
79.5
77.8
74.0
0.76
0.89
3.8
7.2
3.3
ANGK-071BR-02
1PS1070-
■
BD
■
■
-3AA4
25
0.0004
0.63
71 B
3460
1.74
IE2
81.0
79.6
75.8
0.78
1.25
3.8
7.2
3.8
ANGK-071BS-02
1PS1071-
■
BD
■
■
-3AA4
26
0.0005
0.86
80 B
3410
2.41
IE2
79.0
80.5
80.5
0.86
1.59
1.9
5.2
2.3
ANGK-080BR-02
1PS1080-
■
BD
■
■
-3AA4
27
0.0008
1.27
80 B
3430
3.54
IE2
83.3
84.0
82.5
0.85
2.25
2.7
6.3
3.3
ANGK-080BS-02
1PS1081-
■
BD
■
■
-3AA4
29
0.0011
1.75
90 L
3480
4.80
IE2
84.0
84.0
83.0
0.85
3.10
2.6
7.4
3.8
ANGK-090LR-02
1PS1095-
■
BD
■
■
-3AA4
33
0.0017
2.55
90 L
3485
7.00
IE2
85.5
85.5
84.5
0.86
4.35
2.6
7.6
3.9
ANGK-090LS-02
1PS1098-
■
BD
■
■
-3AA4
36
0.0021
3.45
100 L
3510
9.40
IE2
87.5
87.1
85.2
0.86
5.80
2.4
7.7
3.5
ANGK-100LS-02
1PS1106-
■
BD
■
■
-3AA4
53
0.0044
4.55
112 M
3540
12.3
IE2
88.5
88.6
87.3
0.87
7.40
2.2
8.3
3.3
ANGK-112MS-02
1PS1113-
■
BD
■
■
-3AA4
61
0.0092
6.3
132 S
3550
16.9
IE2
90.0
90.5
89.6
0.88
10.0
1.8
6.9
2.9
ANGK-132SR-02
1PS1131-
■
BD
■
■
-3AA4
90
0.020
8.6
132 S
3550
23.1
IE2
90.6
91.0
90.5
0.89
13.4
2.0
7.4
3.1
ANGK-132SS-02
1PS1132-
■
BD
■
■
-3AA4
95
0.024
12.6
160 M
3555
33.8
IE2
91.2
91.4
90.7
0.88
19.7
2.1
7.4
3.2
ANGK-160MR-02
1PS1163-
■
BD
■
■
-3AA4
165
0.045
17.3
160 M
3555
46.5
IE2
91.0
91.0
90.0
0.89
27.0
2.4
7.6
3.4
ANGK-160MS-02
1PS1165-
■
BD
■
■
-3AA4
173
0.053
21.3
160 L
3555
57.0
IE2
92.9
93.0
92.4
0.89
32.5
2.9
7.9
3.6
ANGK-160LS-02
1PS1166-
■
BD
■
■
-3AA4
183
0.061
24.5
180 M
3540
66.0
IE2
93.0
93.3
92.7
0.88
37.5
2.8
7.7
3.8
ANGK-180MS-02
1PS1183-
■
BD
■
■
-3AA4
222
0.069
33.5
200 L
3560
90.0
IE2
93.0
92.8
91.5
0.87
52.0
2.5
6.9
3.3
ANGK-200LR-02
1PS1206-
■
BD
■
■
-3AA4
310
0.13
41.5
200 L
3560
111
IE2
93.7
93.8
93.0
0.88
63.0
2.9
7.3
3.5
ANGK-200LS-02
1PS1208-
■
BD
■
■
-3AA4
330
0.15
51
225 M
3565
137
IE2
93.5
93.6
92.8
0.89
77.0
2.7
7.6
3.7
ANGK-225MS-02
1PS1223-
■
BD
■
■
-3AA4
410
0.23
62
250 M
3580
165
IE2
93.5
93.2
92.0
0.89
94.0
2.3
6.8
3.1
ANGK-250MM-02
1PS1253-
■
BD
■
■
-3AA4
475
0.40
84
280 S
3578
224
IE2
94.8
94.6
93.8
0.87
128
2.5
7.2
3.1
ANGK-280SL-02
1PS1280-
■
BD
■
■
-3AA4
640
0.71
101
280 M
3575
270
IE2
94.5
94.4
93.4
0.89
151
2.5
7.2
3.1
ANGK-280MM-02
1PS1283-
■
BD
■
■
-3AA4
685
0.83
123
315 S
3580
328
IE2
94.5
94.3
93.0
0.90
182
2.4
7.0
3.0
ANGK-315SL-02
1PS1311-
■
BD
■
■
-3AA4
930
1.3
148
315 M
3582
395
IE2
95.3
95.3
94.5
0.91
215
2.4
7.2
3.1
ANGK-315ML-02
1PS1313-
■
BD
■
■
-3AA4
1015 1.6
180
315 M
3580
480
IE2
95.4
95.3
94.4
0.92
255
2.5
7.0
3.0
ANGK-315MN-02
1PS1315-
■
BD
■
■
-3AA4
1055 1.8
224
315 L
3580
597
IE2
95.5
95.6
95.0
0.92
320
2.9
7.4
3.0
ANGK-315LL-02
1PS1316-
■
BD
■
■
-3AA4
1325 2.2
270
315 L
3582
720
IE2
96.0
96.0
95.6
0.92
385
3.4
9.5
3.7
ANGK-315LN-02
1PS1318-
■
BD
■
■
-3AA4
1500 3.5
LOHER VARIO
400
355 L
3583
1066
1)
96.4
96.3
95.6
0.92
540
1.15 6.7
2.75
ANSK-355LC-02
1PS1357-
■
BH
■
■
-3AA0
2100 3.6
450
355 L
3585
1198
1)
96.6
96.5
95.7
0.92
610
1.2
7.4
3.0
ANSK-355LD-02
1PS1358-
■
BH
■
■
-3AA0
2200 4.0
500
355 L
3579
1334
1)
96.3
96.2
95.5
0.91
680
0.90 6.3
2.65
ANSK-355LX-02
1PS1358-
■
BJ
■
■
-3AA0
2300 5.0
500
400 L
3581
1333
1)
96.4
96.3
95.5
0.90
690
0.65 5.7
2.45
ANSK-400LL-02
1PS1404-
■
BJ
■
■
-3AA0
2400 6.0
560
400 L
3584
1492
1)
96.6
96.5
95.7
0.91
770
0.80 6.5
2.8
ANSK-400LN-02
1PS1405-
■
BJ
■
■
-3AA0
2600 7.0
630
400 L
3583
1679
1)
96.7
96.6
96.0
0.91
860
0.75 6.1
2.65
ANSK-400LN-02
1PS1407-
■
BJ
■
■
-3AA0
2600 7.0
710
400 L
2585
1891
1)
96.7
96.6
95.9
0.91
675
2)
0.80 6.5
2.75
ANSK-400LX-02
1PS1408-
■
BJ
■
■
-3AA0
2900 8.3
710
450 L
3586
1890
1)
96.3
96.1
95.1
0.90
685
2)
0.70 6.2
2.7
ANSK-450LL-02
1PS1455-
■
BJ
■
■
-3AA0
3500 12
800
450 L
3586
2130
1)
96.5
96.3
95.3
0.91
762
2)
0.80 6.4
2.85
ANSK-450LN-02
1PS1457-
■
BJ
■
■
-3AA0
3900 14
900
450 L
3586
2396
1)
96.6
96.4
95.6
0.90
865
2)
0.80 6.4
2.8
ANSK-450LN-02
1PS1458-
■
BJ
■
■
-3AA0
3900 14
Operating modes
Frame size
Order code
Line operation
71 ... 450
0
–
Converter operation, standard insulation
3)
71 ... 450
1
–
Converter operation with special insulation (derating approx. 5 %)
3) 4)
160 ... 450
2
–
Line operation, pre-formed coil
450
3
–
Converter operation, pre-formed coil
450
4
–
Voltages
Frame size
Order code
For other voltages,
see Page 2/110
71 ... 450
9
…
Types of construction
Frame size
Order code
IM B3
71 ... 450
0
–
IM B5
71 ... 315
1
–
IM B34
71 ... 112
2
–
IM B14
71 ... 112
3
–
IM V1/cover
71 ... 450
4
–
IM B35
71 ... 450
6
–
For other types of construction,
see from Page 1/29 and 2/111
71 ... 450
9
…
1)
Outside the IE code classification according to IEC 60034-30-1.
2)
Only possible with 690 V (values apply to 690 V).
3)
Can only be ordered with additional identification code
-Z
and order code
M73
.
4)
Insulation 2.15 kV IEC/TS 60035-25:2007 curve B.
© Siemens AG 2016