SIEMENS
2/97
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS1 motor series
Motors with High Efficiency IE2 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rat.,
50 Hz
Frame
size
n
rated,
50 Hz
T
rated,
50 Hz
IE
class
rated,
50 Hz,
4/4
rated,
50 Hz,
3/4
rated,
50 Hz,
2/4
cos
rat.,
50 Hz, 4/4
I
rated,
50 Hz,
400 V
I
rated,
50 Hz,
500 V
I
rated,
50 Hz,
690 V
T
LR
/
T
rat.
I
LR
/
I
rat.
T
B
/
T
rat.
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
A
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: High Efficiency IE2 in accordance with IEC 60034-30-1
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Non sparking" in accordance with EN 60079-15; 2010: II 3G Ex nA IIC T3 Gc
6-pole: 1000 rpm at 50 Hz
LOHER CHEMSTAR
0.25
71 B
870
2.74 –
63.5 64.0 60.0 0.73
0.78 0.62 0.45 2.2
2.6
2.0
ANGK-071BS-06
1PS1071-
■
BD
■
■
-3CA4
26
0.0008
0.37
80 B
925
3.82 IE2
72.0 72.1 69.5 0.70
1.06 0.85 0.61 2.1
4.0
2.4
ANGK-080BR-06
1PS1080-
■
BD
■
■
-3CA4
28
0.0020
0.55
80 B
930
5.60 IE2
74.4 74.4 71.0 0.68
1.57 1.26 0.91 2.5
4.4
2.9
ANGK-080BS-06
1PS1081-
■
BD
■
■
-3CA4
30
0.0030
0.75
90 L
935
7.70 IE2
75.9 76.1 74.0 0.70
2.05 1.63 1.18 2.0
4.1
2.5
ANGK-090LR-06
1PS1095-
■
BD
■
■
-3CA4
33
0.0038
1.1
90 L
935
11.2 IE2
78.1 78.0 76.5 0.71
2.85 2.30 1.66 2.2
4.4
2.6
ANGK-090LS-06
1PS1098-
■
BD
■
■
-3CA4
36
0.0054
1.5
100 L
970
14.8 IE2
83.4 84.0 82.5 0.73
3.55 2.85 2.05 2.0
5.4
2.8
ANGK-100LS-06
1PS1106-
■
BD
■
■
-3CA4
54
0.011
2.2
112 M
965
21.8 IE2
84.8 85.8 85.2 0.75
5.00 4.00 2.90 2.0
5.0
2.8
ANGK-112MS-06
1PS1113-
■
BD
■
■
-3CA4
64
0.014
3
132 S
970
29.5 IE2
85.0 85.8 84.5 0.72
7.10 5.70 4.10 1.6
5.0
2.5
ANGK-132SR-06
1PS1131-
■
BD
■
■
-3CA4
89
0.024
4
132 M
970
39.4 IE2
85.2 85.8 85.2 0.75
9.00 7.20 5.20 1.6
5.0
2.3
ANGK-132MR-06
1PS1133-
■
BD
■
■
-3CA4
95
0.029
5.5
132 M
970
54.0 IE2
87.0 87.8 87.7 0.76
12.0 9.60 7.00 1.9
5.6
2.6
ANGK-132MS-06
1PS1135-
■
BD
■
■
-3CA4
103
0.037
7.5
160 M
975
73.0 IE2
87.8 88.7 88.2 0.74
16.7 13.3 9.70 1.9
4.5
2.2
ANGK-160MR-06
1PS1163-
■
BD
■
■
-3CA4
177
0.075
11
160 L
975
108
IE2
88.7 89.6 89.2 0.76
23.5 18.8 13.7 1.9
5.0
2.2
ANGK-160LS-06
1PS1166-
■
BD
■
■
-3CA4
190
0.098
15
180 L
975
147
IE2
89.9 90.6 90.2 0.78
31.0 24.5 17.9 2.5
6.0
3.1
ANGK-180LS-06
1PS1186-
■
BD
■
■
-3CA4
230
0.17
18.5
200 L
978
181
IE2
90.4 91.3 91.2 0.82
36.0 29.0 21.0 2.4
5.8
2.6
ANGK-200LR-06
1PS1206-
■
BD
■
■
-3CA4
300
0.25
22
200 L
978
215
IE2
90.9 91.6 91.2 0.82
42.5 34.0 24.5 2.5
6.2
2.6
ANGK-200LS-06
1PS1208-
■
BD
■
■
-3CA4
320
0.30
30
225 M
980
292
IE2
91.7 92.5 92.3 0.83
57.0 45.5 33.0 2.5
6.1
2.8
ANGK-225MS-06
1PS1223-
■
BD
■
■
-3CA4
412
0.58
37
250 M
982
360
IE2
92.3 93.1 93.1 0.83
70.0 56.0 40.5 2.8
6.0
2.5
ANGK-250MM-06
1PS1253-
■
BD
■
■
-3CA4
485
0.86
45
280 S
985
436
IE2
92.7 93.7 94.0 0.85
82.0 66.0 48.0 2.7
6.3
2.6
ANGK-280SL-06
1PS1280-
■
BD
■
■
-3CA4
605
1.1
55
280 M
985
533
IE2
93.1 93.9 94.0 0.86
99.0 79.0 57.0 2.5
6.4
2.6
ANGK-280MM-06
1PS1283-
■
BD
■
■
-3CA4
655
1.4
75
315 S
988
725
IE2
93.7 94.0 93.6 0.84
138
110
80.0 2.5
6.6
2.8
ANGK-315SL-06
1PS1311-
■
BD
■
■
-3CA4
865
2.1
90
315 M
988
870
IE2
94.0 94.3 94.0 0.84
165
132
95.0 2.6
6.9
2.8
ANGK-315ML-06
1PS1313-
■
BD
■
■
-3CA4
920
2.5
110
315 M
988
1063 IE2
94.5 95.0 94.9 0.86
195
156
113
2.7
7.0
2.8
ANGK-315MM-06
1PS1314-
■
BD
■
■
-3CA4
1045 3.6
132
315 M
988
1276 IE2
94.7 95.1 95.0 0.86
235
187
136
3.0
7.5
2.9
ANGK-315MN-06
1PS1315-
■
BD
■
■
-3CA4
1115 4.0
160
315 L
988
1546 IE2
94.8 95.0 94.7 0.86
285
225
164
3.1
7.7
3.3
ANGK-315LL-06
1PS1316-
■
BD
■
■
-3CA4
1345 4.7
200
315 L
990
1929 IE2
95.1 95.4 95.1 0.83
365
295
210
2.8
7.5
3.3
ANGK-315LM-06
1PS1317-
■
BD
■
■
-3CA4
1515 7.6
LOHER VARIO
280
355 L
993
2691 IE2
96.1 96.1 95.5 0.85
495
395
286
1.2
6.4
2.35
ANSK-355LC-06
1PS1357-
■
BH
■
■
-3CA0
2350 10.5
315
355 L
994
3027 IE2
96.2 96.2 95.5 0.84
560
450
325
1.35 6.6
2.5
ANSK-355LD-06
1PS1358-
■
BH
■
■
-3CA0
2400 11.5
355
355 L
993
3415 IE2
96.3 96.3 95.8 0.85
630
505
360
1.0
5.6
2.3
ANSK-355LN-06
1PS1357-
■
BJ
■
■
-3CA0
2400 12.5
400
355 L
992
3849
1)
96.3 96.4 95.9 0.84
715
575
415
1.0
5.6
2.25
ANSK-355LN-06
1PS1358-
■
BJ
■
■
-3CA0
2400 12.5
400
400 L
994
3844
1)
96.3 96.4 95.8 0.84
715
575
415
1.0
5.6
2.3
ANSK-400LL-06
1PS1404-
■
BJ
■
■
-3CA0
2800 18.0
450
400 L
994
4323
1)
96.4 96.4 95.9 0.84
800
640
465
1.0
5.5
2.25
ANSK-400LN-06
1PS1405-
■
BJ
■
■
-3CA0
3100 21.5
500
400 L
994
4805
1)
96.5 96.5 96.0 0.84
890
710
515
1.05 5.7
2.3
ANSK-400LN-06
1PS1407-
■
BJ
■
■
-3CA0
3100 21.5
560
450 L
995
5374
1)
96.7 96.7 96.2 0.85
980
785
570
0.95 5.8
2.3
ANSK-450LL-06
1PS1453-
■
BJ
■
■
-3CA0
4100 34.0
630
450 L
995
6046
1)
96.8 96.8 96.3 0.85
1105 885
640
0.95 5.7
2.3
ANSK-450LL-06
1PS1455-
■
BJ
■
■
-3CA0
4100 34.0
710
450 L
995
6813
1)
96.9 97.0 96.5 0.85
1240 995
720
0.95 5.7
2.25
ANSK-450LN-06
1PS1457-
■
BJ
■
■
-3CA0
4400 40.0
800
450 L
995
7676
1)
97.0 97.0 96.5 0.85
–
1125 815
1.0
5.9
2.35
ANSK-450LN-06
1PS1458-
■
BJ
■
■
-3CA0
4400 40.0
900
500 L
995
8635
1)
96.8 96.8 96.2 0.85
–
–
915
1.0
5.8
2.25
ANSK-500LL-06
1PS1505-
■
BJ
■
■
-3CA0
5400 60.0
1000 500 L
995
9592
1)
96.9 96.8 96.2 0.85
–
–
1015 1.0
6.0
2.25
ANSK-500LN-06
1PS1507-
■
BJ
■
■
-3CA0
6100 72.0
1120 500 L
995
10746
1)
96.9 96.9 96.4 0.86
–
–
1120 1.0
5.7
2.15
ANSK-500LN-06
1PS1508-
■
BJ
■
■
-3CA0
6100 72.0
Operating modes
Frame size
Order code
Line operation
71 ... 450
0
–
Converter operation, standard insulation
2)
71 ... 450
1
–
Converter operation with special insulation (derating approx. 5 %)
2) 3)
160 ... 500
2
–
Line operation, pre-formed coil
500
3
–
Converter operation, pre-formed coil
450 ... 500
4
–
Voltages
Frame size
Order code
690 V
, 50 Hz
355 ... 500
0
–
230 V/400 V, 50 Hz
71 ... 112
1
–
500 VY, 50 Hz
71 ... 315
4)
3
–
500 V
, 50 Hz
355 ... 450
5
–
400 V/690 V, 50 Hz
71 ... 400
6
–
690 VY, 50 Hz
71 ... 400
8
–
For other voltages,
see Page 2/110
71 ... 500
9
…
Types of construction
Frame size
Order code
IM B3
71 ... 500
0
–
IM B5
71 ... 315
1
–
IM B34
71 ... 112
2
–
IM B14
71 ... 112
3
–
IM V1/cover
71 ... 450
4
–
IM B35
71 ... 500
6
–
For other types of construction,
see from Page 1/29 and 2/111
71 ... 500
9
…
1)
Outside the IE code classification according to IEC 60034-30-1.
2)
Can only be ordered with additional identification code
-Z
and
order code
M73
.
3)
Insulation 2.15 kV IEC/TS 60035-25:2007 curve B.
4)
Up to 200 kW.
© Siemens AG 2016