SIEMENS
2/62
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series
Pole-changing motors in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Article No.
P
rat.1,
50 Hz
P
rat.2,
50 Hz
Frame
size
n
rat.1,
50 Hz
T
rat.1,
50 Hz
rat.1,
50 Hz,
4/4
cos
rat.1,
50 Hz,
4/4
I
rat.1,
50 Hz,
400 V
T
LR
/
T
rat.1,
50 Hz
I
LR
/
I
rat.1,
50 Hz
T
B
/
T
rat.1,
50 Hz
n
rat.2,
50 Hz
T
rat.2,
50 Hz
rat.2,
50 Hz,
4/4
cos
rat.2,
50 Hz,
4/4
I
rat.2,
50 Hz,
400 V
T
LR
/
T
rat.2,
50 Hz
I
LR
/
I
rat.2,
50 Hz
T
B
/
T
rat.2,
50 Hz
m
IM B3
J
kW
kW
FS
rpm
Nm
%
A
rpm
Nm
%
A
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Line operation: double pole-changing for square-law load torque
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: II 2G Ex d(e) IIC T4 Gb
4/2-pole: 1500/3000 rpm at 50 Hz with one winding connected in Dahlander circuit
1500
rpm
3000
rpm
1500
rpm
3000
rpm
LOHER CHEMSTAR
0.65
2.4
100 L
1415 4.40 75.0 0.86 1.45 1.6
4.1
1.8
2800 8.20 70.0 0.88 5.60 1.8
4.2
1.8
1PS5106-
■
ND
■
■
-4NA4
61
0.0059
0.8
3.1
100 L
1435 5.30 79.0 0.85 1.72 1.9
5.2
2.8
2840 10.4 77.3 0.90 6.40 2.1
5.2
2.8
1PS5108-
■
ND
■
■
-4NA4
64
0.0078
1.1
4.4
112 M
1455 7.20 83.4 0.85 2.25 2.2
6.1
2.5
2885 14.6 80.8 0.92 8.50 2.1
6.4
2.5
1PS5113-
■
ND
■
■
-4NA4
69
0.010
1.45
5.9
132 S
1460 9.50 84.0 0.84 2.95 1.6
5.8
2.8
2875 19.6 80.0 0.89 12.0 1.8
5.6
2.8
1PS5131-
■
ND
■
■
-4NA4
108
0.019
2
8
132 M
1455 13.1 85.0 0.85 4.00 1.8
5.6
2.8
2880 26.5 82.0 0.92 15.3 1.8
6.3
2.8
1PS5133-
■
ND
■
■
-4NA4
113
0.024
2.9
11.5
160 M
1465 18.9 86.5 0.86 5.60 1.8
5.9
2.9
2870 38.3 82.0 0.92 22.0 1.8
6.0
2.9
1PS5163-
■
ND
■
■
-4NA4
178
0.044
4.3
16
160 L
1455 28.2 87.0 0.85 8.40 1.6
6.0
2.3
2920 52.3 86.0 0.94 28.5 1.9
7.1
2.3
1PS5166-
■
ND
■
■
-4NA4
197
0.068
6/4-pole: 1000/1500 rpm at 50 Hz with two windings
1000
rpm
1500
rpm
1000
rpm
1500
rpm
LOHER CHEMSTAR
0.6
1.7
100 L
970
5.90 55.5 0.62 2.50 1.7
3.4
2.7
1435 11.3 76.2 0.83 3.90 1.8
4.6
2.7
1PS5106-
■
ND
■
■
-4PA4
61
0.0059
0.8
2.1
100 L
955
8.00 64.2 0.77 2.35 1.2
3.4
2
1435 14.0 78.4 0.84 4.60 2.0
5.4
2.0
1PS5108-
■
ND
■
■
-4PA4
64
0.0078
0.9
3
112 M
975
8.80 64.7 0.66 3.05 1.6
3.9
2.5
1455 19.7 81.4 0.78 6.80 2.1
6.4
2.5
1PS5113-
■
ND
■
■
-4PA4
69
0.010
1.2
3.9
132 S
980
11.7 72.3 0.70 3.40 1.4
4.6
2.5
1455 25.6 83.1 0.83 8.20 1.5
5.7
2.5
1PS5131-
■
ND
■
■
-4PA4
108
0.019
1.7
5.4
132 M
980
16.6 74.1 0.71 4.65 1.7
5.0
2.5
1465 35.2 85.9 0.82 11.1 2.0
6.9
2.5
1PS5133-
■
ND
■
■
-4PA4
113
0.024
2.5
7.2
160 M
985
24.2 77.7 0.71 6.50 1.5
4.7
2.6
1470 46.8 86.9 0.85 14.1 1.8
6.3
2.6
1PS5163-
■
ND
■
■
-4PA4
178
0.044
3.7
12
160 L
985
35.9 82.4 0.69 9.40 2.3
6.2
3.5
1475 77.7 87.9 0.80 24.5 2.1
7.5
3.5
1PS5166-
■
ND
■
■
-4PA4
197
0.059
6.5
19
180 L
985
63.0 81.0 0.70 16.5 1.8
5.5
2.7
1475 123
90.0 0.80 38.0 2.5
8.1
3.7
1PS5186-
■
ND
■
■
-4PA4
254
132
9.5
26
200 L
985
92.0 84.5 0.70 23.0 2.3
6.5
2.8
1475 168
91.0 0.80 52.0 2.3
7.5
3.4
1PS5208-
■
ND
■
■
-4PA4
340
173
8/4-pole: 750/1500 rpm at 50 Hz with one winding connected in Dahlander circuit
750
rpm
1500
rpm
750
rpm
1500
rpm
LOHER CHEMSTAR
0.5
2
100 L
720
6.60 52.0 0.50 2.80 1.3
3.3
3.4
1440 13.3 82.0 0.79 4.45 3.0
7.5
3.4
1PS5106-
■
ND
■
■
-4QA4
61
0.0078
0.65
2.5
100 L
715
8.70 56.0 0.58 2.90 1.0
3.2
2.6
1425 16.8 81.0 0.84 5.30 2.3
6.3
2.6
1PS5108-
■
ND
■
■
-4QA4
64
0.0078
0.9
3.6
112 M
715
12.0 56.0 0.57 4.05 1.0
2.8
2.1
1430 24.0 82.0 0.84 7.50 1.9
5.6
2.1
1PS5113-
■
ND
■
■
-4QA4
69
0.010
1.1
4.7
132 S
730
14.4 62.0 0.54 4.75 1.0
3.2
2.2
1430 31.4 82.0 0.86 9.60 1.7
5.2
2.2
1PS5131-
■
ND
■
■
-4QA4
108
0.019
1.4
6.4
132 M
730
18.3 67.5 0.52 5.80 1.1
3.5
2.3
1440 42.4 84.5 0.87 12.6 1.9
5.7
2.3
1PS5133-
■
ND
■
■
-4QA4
113
0.024
2.2
9.5
160 M
730
28.8 80.6 0.63 6.30 1.5
4.0
2.5
1465 61.9 86.1 0.84 19.0 2.0
6.3
2.5
1PS5163-
■
ND
■
■
-4QA4
178
0.044
3.3
14
160 L
735
42.9 81.4 0.56 10.4 2.5
4.8
3.3
1475 90.6 85.8 0.73 32.5 2.5
7.2
3.3
1PS5166-
■
ND
■
■
-4QA4
197
0.056
4.5
16
180 M
730
59.0 79.3 0.59 13.9 1.4
3.8
2.3
1470 104
84.6 0.83 33.0 1.4
7.0
2.9
1PS5183-
■
ND
■
■
-4QA4
244
128
5
18.5
180 L
730
65.0 78.3 0.60 15.4 1.5
3.8
2.1
1470 120
86.6 0.83 37.0 2.3
7.0
2.7
1PS5186-
■
ND
■
■
-4QA4
254
132
7.5
28
200 L
735
97.0 85.0 0.60 21.0 1.7
4.0
2.1
1475 181
90.5 0.85 53.0 2.7
7.4
3.1
1PS5206-
■
ND
■
■
-4QA4
340
173
LOHER VARIO
on request
Operating modes
Frame size
Order code
Line operation
100 ... 200
0
–
Converter operation, standard insulation
100 ... 200
1
–
Voltages
Frame size
Order code
230 V, 50 Hz
100 ... 200
1
–
500 VY, 50 Hz
100 ... 200
3
–
400 V, 50 Hz
100 ... 200
6
–
690 VY, 50 Hz
100 ... 200
8
–
For other voltages,
see Page 2/65
100 ... 200
9
…
Types of construction
Frame size
Order code
IM B3
100 ... 200
0
–
IM B5
100 ... 200
1
–
IM B34
100 ... 112
2
–
IM B14
100 ... 112
3
–
IM V1/cover
100 ... 200
4
–
IM B35
100 ... 200
6
–
For other types of construction,
see from Page 1/29 and 2/66
100 ... 200
9
…
© Siemens AG 2016