SIEMENS
2/51
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series
Motors with High Efficiency IE2 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Motor type
Article No.
P
rat.,
50 Hz
Frame
size
J
kW
FS
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: II 2G Ex d(e) IIC T4 Gb
14-pole: 430 rpm at 50 Hz
LOHER CHEMSTAR
on request
LOHER VARIO
110
355 L
DNS
■
-355LB-14
1PS
■
356-
■
BH
■
■
-4GA0
2250
125
355 L
DNS
■
-355LC-14
1PS
■
357-
■
BH
■
■
-4GA0
2500
140
355 L
DNS
■
-355LD-14
1PS
■
358-
■
BH
■
■
-4GA0
2600
160
400 L
DNS
■
-400LL-14
1PS
■
404-
■
BJ
■
■
-4GA0
3400
180
400 L
DNS
■
-400LN-14
1PS
■
405-
■
BJ
■
■
-4GA0
3700
200
400 L
DNS
■
-400LN-14
1PS
■
407-
■
BJ
■
■
-4GA0
3700
225
400 L
DNS
■
-400LX-14
1PS
■
408-
■
BJ
■
■
-4GA0
3900
250
450 L
DNS
■
-450LL-14
1PS
■
454-
■
BJ
■
■
-4GA0
4700
280
450 L
DNS
■
-450LN-14
1PS
■
455-
■
BJ
■
■
-4GA0
5100
315
450 L
DNS
■
-450LN-14
1PS
■
457-
■
BJ
■
■
-4GA0
5100
340
450 L
DNS
■
-450LX-14
1PS
■
458-
■
BJ
■
■
-4GA0
5300
355
500 L
DNS
■
-500LL-14
1PS
■
504-
■
BJ
■
■
-4GA0
6200
400
500 L
DNS
■
-500LN-14
1PS
■
505-
■
BJ
■
■
-4GA0
7000
450
500 L
DNS
■
-500LN-14
1PS
■
507-
■
BJ
■
■
-4GA0
7000
500
500 L
DNS
■
-500LX-14
1PS
■
508-
■
BJ
■
■
-4GA0
7200
16-pole: 375 rpm at 50 Hz
LOHER CHEMSTAR
on request
LOHER VARIO
90
355 L
DNS
■
-355LB-16
1PS
■
356-
■
BH
■
■
-4HA0
2250
100
355 L
DNS
■
-355LC-16
1PS
■
357-
■
BH
■
■
-4HA0
2500
110
355 L
DNS
■
-355LD-16
1PS
■
358-
■
BH
■
■
-4HA0
2600
132
400 L
DNS
■
-400LL-16
1PS
■
405-
■
BJ
■
■
-4HA0
3400
160
400 L
DNS
■
-400LN-16
1PS
■
407-
■
BJ
■
■
-4HA0
3700
180
400 L
DNS
■
-400LX-16
1PS
■
408-
■
BJ
■
■
-4HA0
3900
200
450 L
DNS
■
-450LL-16
1PS
■
454-
■
BJ
■
■
-4HA0
4700
225
450 L
DNS
■
-450LN-16
1PS
■
455-
■
BJ
■
■
-4HA0
5100
250
450 L
DNS
■
-450LN-16
1PS
■
457-
■
BJ
■
■
-4HA0
5100
265
450 L
DNS
■
-450LX-16
1PS
■
458-
■
BJ
■
■
-4HA0
5300
280
500 L
DNS
■
-500LL-16
1PS
■
504-
■
BJ
■
■
-4HA0
6200
315
500 L
DNS
■
-500LN-16
1PS
■
505-
■
BJ
■
■
-4HA0
7000
355
500 L
DNS
■
-500LN-16
1PS
■
507-
■
BJ
■
■
-4HA0
7000
400
500 L
DNS
■
-500LX-16
1PS
■
508-
■
BJ
■
■
-4HA0
7200
Degrees of protection
Frame size
Order code
Ex de IIB/Ex d IIB
355 ... 500
L
4
–
Ex de IIC/Ex d IIC
355 ... 500
W
5
–
Operating modes
Frame size
Order code
Line operation
355 ... 450
0
–
Converter operation, standard insulation
355 ... 450
1
–
Converter operation with special insulation (derating approx. 5 %)
1)
355 ... 500
2
–
Line operation, pre-formed coil
500
3
–
Converter operation, pre-formed coil
500
4
–
Voltages
Frame size
Order code
690 V
, 50 Hz
355 ... 500
0
–
500 V
, 50 Hz
355 ... 450
5
–
400 V/690 V, 50 Hz
355 ... 400
6
–
690 VY, 50 Hz
355 ... 400
8
–
For other voltages,
see Page 2/65
355 ... 500
9
…
Types of construction
Frame size
Order code
IM B3
355 ... 500
0
–
IM V1/cover
355 ... 450
4
–
IM B35
355 ... 500
6
–
For other types of construction,
see from Page 1/29 and 2/66
355 ... 500
9
…
1)
Insulation 2.15 kV IEC/TS 60035-25:2007 curve B.
© Siemens AG 2016