SIEMENS
2/49
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series
Motors with High Efficiency IE2 in cast-iron and steel versions
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rat.,
50 Hz
Frame
size
n
rated
,
50 Hz
T
rated,
50 Hz
IE
class
rated,
50 Hz,
4/4
rated,
50 Hz,
3/4
rated,
50 Hz,
2/4
cos
rated,
50 Hz, 4/4
I
rated,
50 Hz,
400 V
I
rated,
50 Hz,
500 V
I
rated,
50 Hz,
690 V
T
LR
/
T
rat.
I
LR
/
I
rat.
T
B
/
T
rat.
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
A
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: High Efficiency IE2 in accordance with IEC 60034-30-1
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: II 2G Ex d(e) IIC T4 Gb
8-pole: 750 rpm at 50 Hz
LOHER CHEMSTAR
0.12 71M
640
1.79
IE2
52.0 51.5 45.0 0.66
0.50 0.40 0.29 1.8
1.8 1.8
DNG
W
-071BS-08
1PS
5
071-
■
BD
■
■
-4DA4
27
0.00100
0.25
80 M
705
3.39
IE2
59.0 56.0 49.0 0.54
1.13 0.91 0.66 2.0
2.5 2.5
DNG
W
-080BS-08
1PS
5
081-
■
BD
■
■
-4DA4
29
0.00246
0.37
90 S
675
5.20
IE2
59.0 59.0 53.0 0.71
1.27 1.02 0.74 1.4
2.6 1.7
DNG
W
-090LR-08
1PS
5
095-
■
BD
■
■
-4DA4
34
0.00225
0.55
90 L
665
7.90
IE2
63.0 64.0 61.0 0.73
1.73 1.38 1.00 1.5
2.7 1.7
DNG
W
-090LS-08
1PS
5
098-
■
BD
■
■
-4DA4
35
0.0044
0.75
100 L
705
10.2
IE2
70.5 70.3 65.5 0.60
2.55 2.05 1.48 1.5
3.2 2.1
DNG
W
-100LR-08
1PS
5
106-
■
BD
■
■
-4DA4
53
0.0086
1.1
100 L
695
15.1
IE2
70.8 72.3 69.6 0.65
3.45 2.75 2.00 1.4
3.2 1.9
DNG
W
-100LS-08
1PS
5
108-
■
BD
■
■
-4DA4
61
0.011
1.5
112 M
725
19.8
IE2
79.3 79.4 76.5 0.63
4.35 3.45 2.50 1.6
4.0 2.4
DNG
W
-112MS-08
1PS
5
113-
■
BD
■
■
-4DA4
64
0.017
2.2
132 S
725
29.0
IE2
81.0 81.5 80.2 0.62
6.30 5.10 3.65 1.4
3.5 2.0
DNG
W
-132SR-08
1PS
5
131-
■
BD
■
■
-4DA4
94
0.034
3
132 M
720
39.8
IE2
80.0 81.5 80.0 0.62
8.70 7.00 5.10 1.4
3.7 2.0
DNG
W
-132MS-08
1PS
5
133-
■
BD
■
■
-4DA4
105
0.037
4
160 M
730
52.3
IE2
85.2 86.2 85.0 0.67
10.1 8.10 5.90 1.6
3.7 1.9
DNG
W
-160MR-08
1PS
5
163-
■
BD
■
■
-4DA4
171
0.065
5.5
160 M
730
71.9
IE2
86.5 87.2 86.0 0.67
13.7 11.0 7.90 1.7
3.9 2.0
DNG
W
-160MS-08
1PS
5
165-
■
BD
■
■
-4DA4
178
0.083
7.5
160 L
725
98.8
IE2
87.0 87.5 87.3 0.70
17.8 14.2 10.3 1.6
3.8 1.9
DNG
W
-160LS-08
1PS
5
166-
■
BD
■
■
-4DA4
184
0.098
11
180 L
720
145.9 –
86.9 88.0 87.6 0.70
26.0 21.0 15.1 2.3
4.9 2.6
DNG
W
-180LS-08
1PS
5
186-
■
BD
■
■
-4DA4
245
0.195
15
200 L
718
199.5 –
88.0 89.5 89.9 0.76
32.5 26.0 18.8 2.4
5.4 2.8
DNG
W
-200LS-08
1PS
5
206-
■
BD
■
■
-4DA4
319
0.344
18.5
225 S
730
242
–
89.0 89.9 89.5 0.78
38.5 31.0 22.5 2.2
5.4 2.7
DNG
W
-225SR-08
1PS
5
220-
■
BD
■
■
-4DA4
406
0.43
22
225 M
730
288
–
90.3 91.3 91.1 0.80
44.0 35.0 25.5 2.3
5.5 2.7
DNG
W
-225MS-08
1PS
5
223-
■
BD
■
■
-4DA4
430
0.50
30
250 M
732
391
–
91.3 92.2 92.0 0.80
59.0 47.5 34.5 2.4
5.6 2.7
DNG
W
-250MM-08
1PS
5
253-
■
BD
■
■
-4DA4
540
0.86
37
280 S
736
480
–
91.9 92.5 92.1 0.78
75.0 60.0 43.0 2.3
5.4 2.4
DNG
W
-280SL-08
1PS
5
280-
■
BD
■
■
-4DA4
735
1.1
45
280 M
738
582
–
92.4 92.8 92.4 0.79
89.0 71.0 52.0 2.5
5.7 2.5
DNG
W
-280MM-08
1PS
5
283-
■
BD
■
■
-4DA4
750
1.4
55
315 S
740
710
–
92.9 93.3 92.9 0.80
107
85.0 62.0 2.2
5.8 2.6
DNG
W
-315SL-08
1PS
5
311-
■
BD
■
■
-4DA4
1010 2.0
75
315 M
738
970
–
93.5 94.4 94.5 0.81
143
114
83.0 2.3
5.9 2.7
DNG
W
-315ML-08
1PS
5
313-
■
BD
■
■
-4DA4
1090 2.5
90
315 L
740
1161 –
93.5 94.3 94.4 0.83
167
134
97.0 2.2
5.8 2.5
DNG
W
-315MM-08
1PS
5
314-
■
BD
■
■
-4DA4
1130 3.1
110
315 L
740
1419 –
94.2 95.0 95.1 0.82
205
164
119
2.7
6.7 2.9
DNG
W
-315MN-08
1PS
5
315-
■
BD
■
■
-4DA4
1160 3.9
132
315 L
740
1703 –
94.4 94.8 94.4 0.81
250
199
144
2.9
7.2 3.3
DNG
W
-315LL-08
1PS
5
316-
■
BD
■
■
-4DA4
1340 4.5
LOHER VARIO
200
355 L
744
2566
1)
95.2 95.4 94.8 0.82
370
295
214
1.15 5.8 2.35
DNS
■
-355LB-08
1PS
■
356-
■
BH
■
■
-4DA0
2250 14.7
225
355 L
744
2886
1)
95.3 95.4 94.8 0.81
420
335
243
1.15 5.8 2.4
DNS
■
-355LC-08
1PS
■
357-
■
BH
■
■
-4DA0
2500 15.7
250
355 L
744
3206
1)
95.3 95.4 94.8 0.81
466
373
270
1.2
5.8 2.45
DNS
■
-355LD-08
1PS
■
358-
■
BH
■
■
-4DA0
2600 17.0
280
355 L
743
3597
1)
95.8 96.0 95.6 0.81
520
415
300
1.15 5.2 2.3
DNS
■
-355LN-08
1PS
■
357-
■
BJ
■
■
-4DA0
2700 12.5
315
355 L
743
4049
1)
95.8 96.0 95.6 0.81
580
465
335
1.05 5.1 2.2
DNS
■
-355LX-08
1PS
■
358-
■
BJ
■
■
-4DA0
2850 13.5
355
400 L
743
4559
1)
96.0 96.1 95.6 0.81
655
525
380
1.0
5.1 2.3
DNS
■
-400LL-08
1PS
■
404-
■
BJ
■
■
-4DA0
3400 17.5
400
400 L
744
5136
1)
96.1 96.2 95.8 0.82
735
585
425
0.95 5.2 2.25
DNS
■
-400LN-08
1PS
■
407-
■
BJ
■
■
-4DA0
3700 21.0
450
400 L
743
5779
1)
96.1 96.3 95.9 0.81
830
665
480
0.95 5.0 2.25
DNS
■
-400LX-08
1PS
■
408-
■
BJ
■
■
-4DA0
3900 23.0
500
450 L
745
6411
1)
96.5 96.6 96.1 0.83
900
720
520
0.85 5.2 2.2
DNS
■
-450LL-08
1PS
■
455-
■
BJ
■
■
-4DA0
4700 35.5
560
450 L
745
7178
1)
96.5 96.6 96.1 0.84
1000 800
580
0.85 5.4 2.25
DNS
■
-450LN-08
1PS
■
457-
■
BJ
■
■
-4DA0
5100 42.0
630
450 L
745
8075
1)
96.6 96.7 96.2 0.83
1130 905
655
0.90 5.3 2.25
DNS
■
-450LN-08
1PS
■
458-
■
BJ
■
■
-4DA0
5100 42.0
670
450 L
746
8579
1)
96.7 96.7 96.3 0.83
1210 965
700
0.85 5.2 2.3
DNS
■
-450LX-08
1PS
■
450-
■
BJ
■
■
-4DA0
5300 46.0
710
500 L
746
9086
1)
96.7 96.8 96.2 0.85
1240 995
720
0.85 5.8 2.55
DNS
■
-500LL-08
1PS
■
504-
■
BJ
■
■
-4DA0
6200 73.0
800
500 L
746
10242
1)
96.7 96.8 96.4 0.85
–
1120 810
0.85 5.6 2.45
DNS
■
-500LL-08
1PS
■
505-
■
BJ
■
■
-4DA0
6200 73.0
900
500 L
745
11530
1)
96.5 96.6 96.1 0.84
–
1285 930
1.0
5.5 2.2
DNS
■
-500LN-08
1PS
■
507-
■
BJ
■
■
-4DA0
6900 88.0
950
500 L
746
12152
1)
96.7 96.7 96.1 0.83
–
–
990
0.95 5.9 2.4
DNS
■
-500LX-08
1PS
■
508-
■
BJ
■
■
-4DA0
7100 96.0
Degrees of protection
Frame size
Order code
Ex de IIB/Ex d IIB
355 ... 500
L
4
–
Ex de IIC/Ex d IIC
71 ... 500
W
5
–
Operating modes
Frame size
Order code
Line operation
71 ... 450
0
–
Converter operation, standard insulation
71 ... 450
1
–
Converter operation with special insulation (derating approx. 5 %)
2)
160 ... 500
2
–
Line operation, pre-formed coil
500
3
–
Converter operation, pre-formed coil
500
4
–
Voltages
Frame size
Order code
690 V
, 50 Hz
355 ... 500
0
–
230 V/400 V, 50 Hz
71 ... 112
1
–
500 VY, 50 Hz
71 ... 315
3
–
500 V
, 50 Hz
355 ... 450
5
–
400 V/690 V, 50 Hz
71 ... 400
6
–
690 VY, 50 Hz
71 ... 400
8
–
For other voltages,
see Page 2/65
71 ... 500
9
…
Types of construction
Frame size
Order code
IM B3
71 ... 500
0
–
IM B5
71 ... 315
1
–
IM B34
71 ... 112
2
–
IM B14
71 ... 112
3
–
IM V1/cover
71 ... 450
4
–
IM B35
71 ... 500
6
–
For other types of construction,
see from Page 1/29 and 2/66
71 ... 500
9
…
1)
Outside the IE code classification according to IEC 60034-30-1.
2)
Insulation 2.15 kV IEC/TS 60035-25:2007 curve B.
© Siemens AG 2016