SIEMENS
2/27
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
SIMOTICS XP 1MD5 motor series
Article No. supplements
■
Selection and ordering data
✓
With additional charge
–
Not possible
Without additional charge
✓
With additional charge
–
Not possible
Without additional charge
For dual voltages 230 V/400 V, 220 V/380 V, 400 V/690 V
or 380 V/660 V:
–
For motors for converter operation, the converter rating plate
is stamped with 380 V or 400 V.
Voltages
Voltage
code
11th
position
of the
Article
No.
Additional
identifica-
tion code
with order
code and
plain text if
required
Motor series
SIMOTICS XP
Frame size
1MD5. . . - . . .
■
. - . . . .
71
80
90
100
112
132
160
180
200
225
250
280
315
355
Optional voltages
690 V
, 50 Hz
0
–
–
–
–
–
–
–
–
–
–
–
–
–
O
230 V
/400 VY, 50 Hz
1
O
O
O
O
O
O
O
O
O
–
–
–
–
–
500 VY, 50 Hz
3
O
O
O
O
O
O
O
O
O
O
O
O
O
1)
–
500 V
, 50 Hz
5
✓
✓
✓
✓
✓
O
O
O
O
O
O
O
O
O
400 V
/690 VY, 50 Hz
6
O
O
O
O
O
O
O
O
O
O
O
O
O
O
415 VY, 50 Hz
9
L1C
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1)
–
415 V
, 50 Hz
9
L1D
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
380 V
/660 VY, 50 Hz
9
L1L
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
230/400 V
/Y, 50 Hz and
460 VY, 60 Hz (60 Hz power)
2)
9
L1M
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
–
–
–
–
400/690 V
/Y, 50 Hz and
460 V
, 60 Hz (60-Hz power)
2)
9
L1N
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
230/400 V
/Y, 50 Hz; 400 V
, 87 Hz
(increased power at 87 Hz)
3)
9
L1P
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
–
–
–
–
460 VY, 60 Hz (60 Hz power)
9
L2E
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
–
–
–
–
460 V
, 60 Hz (60-Hz power)
9
L2F
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
575 VY, 60 Hz (60 Hz power)
9
L2L
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
–
575 V
, 60 Hz (60-Hz power)
9
L2M
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
440 V
, 60 Hz (60-Hz power)
9
L2X
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
Types of construction
Type of
con-
struction
code
12th
position
of the
Article
No.
Additional
identifica-
tion code
with order
code and
plain text if
required
Motor series
SIMOTICS XP
Frame size
1MD5. . . - . . . .
■
- . . . .
71
80
90
100
112
132
160
180
200
225
250
280
315
355
Optional types of construction
IM B3
0
O
O
O
O
O
O
O
O
O
O
O
O
O
O
IM B5
1
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
IM B34
2
✓
✓
✓
✓
✓
–
–
–
–
–
–
–
–
–
IM B14
3
✓
✓
✓
✓
✓
–
–
–
–
–
–
–
–
–
IM V1, with protective cover
4
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
IM B35
6
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
IM V6
9
M1E
O
O
O
O
O
O
O
O
O
O
O
O
O
–
IM V5, with protective cover
9
M1F
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
IM V3
9
M1G
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
IM V15, with protective cover
9
M2K
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
IM V18, with protective cover
9
M2M
✓
✓
✓
✓
✓
–
–
–
–
–
–
–
–
–
1)
Up to 200 kW.
2)
Not available for 6-pole motors with 1.1 kW.
3)
For 4-pole motors only.