SIEMENS
2/24
Siemens D 83.1 · 2016
2
Motors with Explosion Protection
SIMOTICS XP 1MD5 motor series
Motors with Premium Efficiency IE3 in cast-iron version
■
Selection and ordering data
(continued)
Operating values at rated power
Motor type
Article No.
P
rated,
60 Hz
Frame
size
n
rated,
60 Hz
T
rated,
60 Hz
IE
class
rated,
60 Hz,
4/4
rated,
60 Hz,
3/4
rated,
60 Hz,
2/4
cos
rated,
60 Hz,
4/4
I
rated,
60 Hz,
460 V
T
LR
/
T
rat.
I
LR
/
I
rat.
T
B
/
T
rat.
m
IM B3
J
kW
FS
rpm
Nm
–
%
%
%
–
A
–
–
–
kg
kgm
2
•
Cooling: self-ventilated (IC 411)
•
Efficiency: Premium Efficiency IE3 according to IEC 60034-30-1
•
Insulation: thermal class 155 (temperature class F), IP55 degree of protection,
utilization in accordance with thermal class 130 (temperature class B), S1-100 %
•
Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: II 2G Ex d(e) IIC T4 Gb
2-pole: 3600 rpm at 60 Hz
0.43
71 B
3445
1.19
IE3
73.4 72.6 68.9 0.76
0.97
3.6
6.0 3.6
DNGW-071BS-02
1MD5070-
■
BD
■
■
-4AH1
27
0.0005
0.63
71 B
3450
1.74
IE3
76.8 76.1 72.9 0.76
1.35
3.9
6.6 3.9
DNGW-071BT-02
1MD5071-
■
BD
■
■
-4AH1
28
0.0006
0.86
80 B
3450
2.38
IE3
77.0 78.0 77.2 0.86
1.63
2.6
6.4 3.1
DNGW-080BS-02
1MD5080-
■
BD
■
■
-4AH1
29
0.0011
1.27
80 B
3480
3.48
IE3
84.0 84.6 83.4 0.85
2.25
2.8
7.4 3.4
DNGW-080BT-02
1MD5081-
■
BD
■
■
-4AH1
30
0.0013
1.75
90 L
3510
4.76
IE3
85.5 85.6 84.0 0.87
2.95
2.6
8.7 4.2
DNGW-090LS-02
1MD5095-
■
BD
■
■
-4AH1
36
0.0021
2.55
90 L
3510
6.90
IE3
86.5 87.0 85.9 0.88
4.20
2.6
8.3 4.2
DNGW-090LT-02
1MD5098-
■
BD
■
■
-4AH1
40
0.0031
3.45
100 L
3520
9.40
IE3
88.5 89.2 88.5 0.89
5.50
3.3
8.5 4.7
DNGW-100LT-02
1MD5106-
■
BD
■
■
-4AH1
56
0.0054
4.55
112 M
3550
12.2
IE3
88.5 88.7 87.6 0.90
7.20
2.6
9.0 4.1
DNGW-112MT-02
1MD5113-
■
BD
■
■
-4AH1
68
0.012
6.3
132 S
3545
17.0
IE3
89.5 89.9 89.1 0.91
9.70
1.9
7.5 3.8
DNGW-132SS-02
1MD5131-
■
BD
■
■
-4AH1
97
0.024
8.6
132 S
3550
23.1
IE3
90.2 90.5 90.0 0.92
13.0
2.1
8.4 4.1
DNGW-132ST-02
1MD5132-
■
BD
■
■
-4AH1
107
0.031
12.6
160 M
3555
33.8
IE3
91.0 90.8 89.3 0.89
19.5
2.4
7.6 3.7
DNGW-160MS-02
1MD5163-
■
BD
■
■
-4AH1
176
0.053
17.3
160 M
3560
46.4
IE3
91.7 91.5 90.3 0.88
27.0
2.7
8.7 4.2
DNGW-160MT-02
1MD5165-
■
BD
■
■
-4AH1
186
0.061
21.3
160 L
3550
57.3
IE3
91.7 91.8 91.1 0.91
32.0
2.7
8.2 3.8
DNGW-160LT-02
1MD5166-
■
BD
■
■
-4AH1
197
0.068
24.5
180 M
3550
65.9
IE3
91.7 91.7 90.6 0.89
37.5
2.3
7.5 3.6
DNGW-180MT-02
1MD5183-
■
BD
■
■
-4AH1
243
0.080
33.5
200 L
3555
90.0
IE3
93.0 93.1 92.6 0.87
52.0
2.5
7.1 3.3
DNGW-200LS-02
1MD5206-
■
BD
■
■
-4AH1
319
0.134
41.5
200 L
3555
111.5 IE3
93.6 93.6 92.9 0.89
63.0
2.5
7.1 3.2
DNGW-200LT-02
1MD5208-
■
BD
■
■
-4AH1
343
0.158
51
225 M
3560
136.8 IE3
93.6 93.9 93.6 0.89
77.0
2.4
6.8 3.2
DNGW-225MT-02
1MD5223-
■
BD
■
■
-4AH1
438
0.26
62
250 M
3575
165.6 IE3
93.6 93.6 92.7 0.90
92.0
2.3
6.7 3.0
DNGW-250MN-02
1MD5253-
■
BD
■
■
-4AH1
535
0.46
75
280 S
3578
200
IE3
94.1 93.9 92.7 0.89
112
2.7
7.6 3.2
DNGW-280SM-02
1MD5280-
■
BD
■
■
-4AH1
700
0.77
90
280 M
3578
240
IE3
95.0 94.8 93.8 0.90
132
2.7
8.1 3.3
DNGW-280MN-02
1MD5283-
■
BD
■
■
-4AH1
755
0.94
123
315 S
3582
328
IE3
95.0 95.0 94.2 0.91
179
2.4
7.2 3.0
DNGW-315SL-02
1MD5311-
■
BD
■
■
-4AH1
1000 1.39
148
315 M
3582
395
IE3
95.4 95.3 94.6 0.91
215
2.5
7.1 3.0
DNGW-315ML-02
1MD5313-
■
BD
■
■
-4AH1
1070 1.6
160
315 M
3582
427
IE3
95.4 95.1 94.6 0.92
230
2.8
7.7 3.1
DNGW-315MN-02
1MD5315-
■
BD
■
■
-4AH1
1150 1.9
224
315 L
3582
597
IE3
95.8 95.9 95.4 0.92
320
2.9
7.1 2.9
DNGW-315LL-02
1MD5316-
■
BD
■
■
-4AH1
1400 2.3
270
315 L
3582
720
IE3
95.8 95.9 95.4 0.92
385
3.4
9.5 3.7
DNGW-315LN-02
1MD5318-
■
BD
■
■
-4AH1
1550 2.5
500
355 M
3580
1334 IE3
96.0 95.8 94.8 0.90
730
2.0
7.5 2.7
DNGW-355MT-02
1)
1MD5357-
■
BD
■
■
-4AA1
2800 6.4
Operating modes
Frame size
Order code
Line operation
71 ... 355
0
–
Converter operation, standard insulation
71 ... 355
1
–
Voltages
Frame size
Order code
For other voltages,
see Page 2/27
71 ... 355
9
…
Types of construction
Frame size
Order code
IM B3
71 ... 355
0
–
IM B5
71 ... 315
1
–
IM B34
71 ... 112
2
–
IM B14
71 ... 112
3
–
IM V1/cover
71 ... 355
4
–
IM B35
71 ... 355
6
–
For other types of construction,
see from Page 1/29 and 2/27
71 ... 355
9
…
1)
Direction of rotation must be specified (order code
K97
or
K98
).
© Siemens AG 2016