SIEMENS
14/18
Siemens IC 10 · 2017
Parameterization, Configuration and Visualization with SIRIUS
SIRIUS Motor Starter Function Block Library for SIMATIC PCS 7
14
■
Overview
Faceplate of the motor block
With the SIRIUS motor starter PCS 7 block library,
SIRIUS ET
200S and ET
200pro motor starters can be easily and
simply integrated into the SIMATIC PCS 7 process control
system. The SIRIUS motor starter PCS 7 function block library
contains the diagnostics and driver blocks corresponding to the
SIMATIC PCS 7 diagnostics and driver concept as well as the
elements (symbols and faceplates) required for operator control
and process monitoring.
Easy integration with the PCS 7 Function Block Library
The PCS 7 block library can be used for simple and easy
integration of SIRIUS ET 200S and ET 200pro motor starters into
the SIMATIC PCS 7 process control system V7 and V8. The focus
here is simple configuration. Functioning of the blocks is based
on the PCS 7 standard libraries and is optimally harmonized with
the functions of the SIRIUS motor starters.
Users who have previously integrated motor feeders into PCS 7
are easily able to switch to SIRIUS motor starters.
All blocks required for the automation systems are provided by
the PCS 7 block library – as are the block symbols and
faceplates for the operator station required for monitoring and
control.
Regardless of whether, for example, the motor starter is
controlled directly, or its current value is to be read out and
status, warning and error signals are to be displayed, the right
modules are always available.
Connection to powerrate
The SIRIUS motor starters can be connected to powerrate. The
block provides the possibility of integrating the motor starters
into energy management.
The current values are supplied directly from the motor starter
block, while the voltage and the power factor (p.f.) must be
entered manually.
Faceplate for diagnostics
Faceplate for energy management with powerrate
■
Benefits
•
Uniform and continuous integration into SIMATIC PCS 7
•
Standardized blocks for simple integration and optimal
operation
•
Greater process transparency due to greater information
density in the process control system
More information
Technical specifications,
see
Programming and Operating Manual for the "SIRIUS Motor Starter PCS 7
Library V7.1 + SP2" and "SIRIUS Motor Starter PCS 7 Library V8 Migration
V8.0 + SP1" block libraries,
see
Getting Started for the "SIRIUS Motor Starter PCS 7 Library V7.1 + SP2" and
"SIRIUS Motor Starter PCS 7 Library V8 Migration V8.0 + SP1" block libraries,
© Siemens AG 2016