SIEMENS
12/116
Siemens IC 10 · 2017
SIRIUS 3SE6 Non-Contact Safety Switches
RFID
3SE63 RFID safety switches
12
Connector assignment
Directions of approach and switching interval
The side area permits a maximum height offset of the switch and
actuator of ±8 mm (e.g. mounting tolerance or due to sagging of
the protective door). The transverse offset also equals
max. ±8 mm.
Switching interval: Output signal with hysteresis
Switching interval: Output signal with OFF delay
Dimension drawings
Type
3SE63
Inputs/outputs
Safety inputs X1/X2
• Input voltage
V DC
24
15/+10 %
• Power consumption per input
mA
5
Safety outputs OSSD1/OSSD2
p operation
• Max. rated operating current
I
e max
A
0.25
• Rated operational current
I
e
/DC-12/DC-13
at
U
e
A
0.25
• Voltage drop
U
e
V
< 1
• Switching frequency
Hz
1
• Response time, max.
ms
100
• Risk time, max.
ms
200
• Recovery, max.
s
5
Diagnostics output
p operation
• Max. rated operating current
I
e2 max
A
0.05
• Rated operational current
I
e
/DC-12/DC-13
at
U
e
A
0.05
• Voltage drop
U
e
V
< 2
• Operational current
mA
150
• Conductor capacity, max.
nF
50
3
8
5
6
7
1
4
2
Pin 1: A1 rated operational voltage 24 V DC
Pin 2: X1 safety input 24 V DC
Pin 3: A2 grounding
Pin 4: OSSD1 safety output
Pin 5: OUT conventional diagnostics output
Pin 6: X2 safety input 24 V DC
Pin 7: OSSD2 safety output
Pin 8: Not used
IC10_00090
max. 18 mm
max. 8 mm
IC01_00086
S
ao
S
n
< 10 mm
= 12 mm
> 16 mm
2 mm
S
ar
S
ao
S
n
OSSD1 /
OSSD2
1
0
S
OFF
S
ON
S
OFF
S
S
ar
RFID switch
3SE6315
RFID actuator
3SE6310
IC01_00087
> 16 mm
U (OSSD1/
OSSD2)
< 200 ms
24 V
0
t
X
x >
S
ar
IC01_00088
9
22
6,2
4,5
A
A
A-A
78
74
2
25
18,5
M 12 x 1
IC01_00089
25
A
A-A
9
4,5
22
91
6,2
78
A
© Siemens AG 2016