SIEMENS
12/65
Siemens IC 10 · 2017
SIRIUS 3SE5, 3SE2 Mechanical Safety Switches
With Tumbler
General data
12
Examples of door interlocking
X-Lock door interlocking from Axelent
For the addresses of the door interlock manufacturers,
see page 16/20
.
Door interlocking from Brühl
■
Technical specifications
1)
Without any welds according to IEC 60947-5-1.
Type
3SE5322
3SE5312
General data
Standards
IEC 60947-5-1, EN 60947-5-1, DIN EN ISO 14119
Rated insulation voltage
U
i
V
250
Degree of pollution
according to IEC 60664-1
Class 3
Rated impulse withstand voltage
U
imp
kV
4
Rated operational voltage
U
e
• DC
V
24
• 50/60 Hz AC
V
230
Conventional thermal current
I
th
A
6
Rated operational current
I
e
• With alternating current 50/60 Hz
I
e
/ AC-15 or B300
-
At 24 V
A
6
-
At 120 V
A
3
-
At 230 V
A
1.5
• For direct current
I
e
/ DC-13 or Q300
-
At 24 V
A
3
-
At 125 V
A
0.55
-
At 250 V
A
0.27
Solenoid
• Locking force, max.
N
1 300
2 600
• Locking force according to EN ISO 14119
N
1 000
2 000
• Power consumption at
U
c
W
3.5
Short-circuit protection
1)
• With DIAZED fuse links,
Operational class gG
A
6
• With miniature circuit breaker, Char. C
A
0.5
Mechanical endurance
1 ×10
6
operating cycles
Electrical endurance
• With 3RH.1, 3RT contactors in size S00, S0
1 ×10
6
operating cycles
• For utilization category AC-15 when switching off
I
e
/AC-15 at 230 V
100 000 operating cycles
• With utilization category DC-12/DC-13
For direct current depending on the loading of the switch
Switching frequency
With 3RH.1, 3RT contactors in size S00, S0
Operat-
ing
cycles
6 000 operating cycles/h
Shock resistance
acc. to IEC 60068-2-27
g / ms
30 / 11
© Siemens AG 2016