Motor Starters for Use in the Field, High Degree of Protection
SIRIUS M200D Motor Starters
Accessories
For all M200D motor starters
9
■
Overview
Power and motor connection on the M200D motor starter
(in this example: M200D for AS-i)
Communication connection using AS-Interface and digital inputs and
outputs
Communication connection using PROFIBUS and digital inputs and
outputs
Communication connection using PROFINET and digital inputs and
outputs
M
1
1
2
3
4
5
6
2
3
6
4
5
Power feeder plug
Power connection plug
Incoming energy supply cable
Motor connection plug
Motor plug
Motor cable
NSA0_00484
NSA0_00485a
7
9
10
8
7
8
9
10
Connection for motor control with AS-i communication
AS-Interface M12 feeder
Connection for digital input
(IO communication, 5-pole)
Connection for digital output
(IO communication, 4 or 5-pole)
NSA0_00488a
11
12
9
10
13
14
13
11
12
14
9
10
Connection for digital input
(IO communication, 5-pole)
Connection for digital output
(IO communication, 4- or 5-pole)
PROFIBUS connection (input)
PROFIBUS connection (loop)
Connection for 24 V supply (infeed)
Connection for 24 V supply (loop)
NSA0_00487a
9
10
13
14
15
13
15
15
14
9
10
Connection for digital input
(IO communication, 5-pole)
Connection for digital output
(IO communication, 4- or 5-pole)
Connection for 24 V supply (infeed)
Connection for 24 V supply (loop)
Connection with PROFINET
(input on the left, loop on the right)