SIEMENS
9/48
Siemens IC 10 · 2017
Motor Starters for Use in the Field, High Degree of Protection
SIRIUS M200D Motor Starters
M200D Motor Starters for PROFIBUS/PROFINET
General data
9
Switching off during dead times
PROFIenergy supports the targeted switching-off of loads
during dead time.
These can be planned short breaks of a few minutes (such as
lunch breaks), longer dead times (such as nights) or unplanned
dead times. Energy is always saved when no power is required.
Measuring and visualizing the energy flow as a basis of energy
management
The objective of energy management is to optimize the use of
energy in a company – from the purchasing of energy through to
the consumption of energy – economically and ecologically.
Analyses of energy consumption over time can be used to
control energy flows, avoid energy peaks, improve ratings and
thus save costs.
PROFIenergy enables consumption data to be read off from the
devices in a unified form. This is recorded during operation and
can be displayed on a control panel, for example, or sent to
overlying energy management software packages. This ensures
that the measured variables are in a uniform manufacturer-inde-
pendent form and structure that is available to the user for further
processing. These PROFIenergy functions thus provide the ba-
sis for active load and energy management during operation.
PROFIenergy in the M200D PROFINET motor starter
The M200D PROFINET motor starter supports the "switching
during dead times" and "current measurement values" functions
of the motor current using PROFIenergy. These are called
commands, because they trigger a reaction in the M200D motor
starter.
✓
Function available
--
Function not available
1)
.
SIRIUS M200D
SIRIUS M200D
PROFIBUS
PROFINET
Device functions (firmware features)
Slave on the bus
Fieldbus
✓
PROFIBUS to M12
✓
PROFINET to M12
Adjustable number of stations
✓
1 ... 125
✓
1 ... 128 for CPU 315, CPU 317
1 ... 1256 for CPU 319
Parameter assignment
DIP switches
✓
For address setting and terminating resistor
--
Motor Starter ES
✓
Through bus, optical interface
PROFIBUS/PROFINET data records
✓
From STEP 7/HW Config
✓
Diagnostics
Acyclic through data records
✓
Diagnostic interrupt support
✓
Process image
Process image
✓
2 bytes PAE/ 2 bytes PAA
Data channels
Local optical interface (manual local)
✓
Motor Starter ES through local interface
✓
Using Motor Starter ES through bus
✓
Data records (acyclic)
Parameterization
✓
Using DS 131 (DS = data record)
Diagnostics
✓
Device-specific DS 92
Measured values
✓
Measured values DS 94
Statistics
✓
Statistical data DS 95
Commands
✓
Using DS 93
Slave pointer
✓
Slave pointer DS 96
Logbook
✓
Using Motor Starter ES and data records: device faults DS 72, tripping operation DS 73, events DS 75
Device identification
✓
Using DS 100
I&M data
✓
Using DS 231 ... 234
✓
Using data records 0xAFF0 ... 0xAFF3
Inputs
Number
✓
4
• Of these in the process image
✓
4
Input action
✓
Parameterizable: flexibly assignable action;
see manual
1)
Quick stop
✓
Parameterizable: latching, non-latching
© Siemens AG 2016