SIEMENS
9/42
Siemens IC 10 · 2017
Motor Starters for Use in the Field, High Degree of Protection
SIRIUS M200D Motor Starters
M200D Motor Starters for AS-Interface
General data
9
✓
Function available
--
Function not available
■
Application
The M200D AS-i standard is particularly suitable for highly auto-
mated applications in conveyor systems requiring devices and
systems to be monitored to prevent or limit plant downtime. The
option of planning the functions of the motor starter or its inter-
faces also creates the prerequisite for fine-adjustment to the
function of the motor starter in the application and hence
provides for extreme flexibility.
For the use of SIRIUS M200D motor starters in conjunction with
highly energy-efficient IE3/IE4 motors, please observe the
information on dimensioning and configuring;
see "Application
Manual for SIRIUS Controls with IE3/IE4 Motors",
.
For more information
see Preface, page 7
.
■
Technical specifications
SIRIUS M200D
SIRIUS M200D
AS-i Basic
AS-i Standard
Device functions (firmware features)
Device function
Repair switch
✓
Current limit monitoring bottom
--
✓
Parameterizable
Current limit monitoring top
--
✓
Parameterizable
Zero current detection
✓
Permanent function: disconnection, less than
18.75 % of the rated operational current
I
e
✓
Parameterizable
Blocking current
✓
Permanent function: starting up of the motor:
Tripping limit up to 800 % of the rated
operational current
I
e
for 10 s
Active operation: Threshold for tripping "blocking
current" up to 400 % of the rated operational
current
I
e
✓
Parameterizable
Asymmetry
✓
Permanent function: up to 30 % of the rated
operational current
I
e
(only mechanical MS)
✓
Parameterizable
Load type
✓
Permanent function: 3-phase
✓
Parameterizable: Single-phase and three-phase
Shutdown class
✓
Parameterizable using DIP switches:
CLASS 10/deactivated
Parameterizable using Motor Starter ES, data
record: CLASS 5, 10, 15, 20
Protection against voltage failure
✓
✓
Parameterizable: activated/deactivated
Soft starter control function
Soft start function
--
✓
Only solid-state version
Bypass function
--
✓
Only solid-state version
More information
Device manuals for SIRIUS M200D AS-i Basic and Standard,
see
FAQs,
Note on security:
In order to protect plants, systems, machines and networks against cyber
threats, it is necessary to implement – and continuously maintain – a holistic,
state-of-the-art industrial security concept. Siemens products and solutions
only represent one component of such a concept.
For more information about the subject of Industrial Security,
see
www.siemens.com/industrialsecurity
.
© Siemens AG 2016