SIEMENS
9/40
Siemens IC 10 · 2017
Motor Starters for Use in the Field, High Degree of Protection
SIRIUS M200D Motor Starters
M200D Motor Starters for AS-Interface
General data
9
■
Overview
For motor control using AS-Interface there are the following
M200D motor starter versions: SIRIUS M200D AS-i Basic and
SIRIUS M200D AS-i Standard (basic functionality,
see page
9/38
"SIRIUS M200D Motor Starters"
➞
"General Data"
➞
"Overview"
).
SIRIUS M200D AS-i Basic
Functionality
•
Easy and fast on-site start up through parameterization of
local setting knobs (DIP switches) and rotary coding switches
for adjusting the rated operational current. The rotary coding
switch has an OFF position for deactivating the overload
protection with the help of the thermal motor model when
using a temperature sensor.
Communications
•
AS-i communication with A/B addressing according to
Spec V2.1
•
The AS-i bus is connected cost-effectively using an
M12 connection on the device. Of the four digital inputs, two
are contained in the process image and can therefore be used
in the PLC program. The other two inputs are locally effective
and permanently assigned with functions.
•
The LEDs can provide comprehensive diagnostics of the
device on the spot. In addition to diagnostics using the
PAE process image, the device can create up to 15 different
diagnostic signals per slave. The message with the highest
priority can be read out through the AS-i communication. This
is yet another new development which distinguishes the
M200D AS-i Basic motor starter from the rest of the market and
adds innovative technology, maximum availability and
transparency to the system.
SIRIUS M200D AS-i Standard
The intelligent and highly flexible M200D AS-i standard motor
starter in A/B technology starts and protects motors and loads
up to 5.5 kW. They are available in direct-on-line or reversing
starter versions, in a mechanical version and also an electronic
version (the latter with soft start function).
The M200D AS-i Standard motor starter is the most functional
member of the SIRIUS motor starter family in the high degree of
protection IP65 for AS-i communication. Consistency with other
products of the SIRIUS M200D motor starter range and with the
frequency converter and ET 200pro I/O system is assured.
Functionality
•
AS-i communication with A/B addressing according to
Spec 3.0
•
Electronic version also with soft start function
•
AS-i slave profile 7AE/7A5 with process image 6E/4A
•
Full TIA integration: All digital inputs and outputs exist in the
cyclic process image and are visible through AS-i, providing
maximum flexibility and best adaptability to the application.
•
Additionally expanded diagnostics using data record through
AS-i bus
•
Complete plant monitoring using statistics data record and
current value monitoring by means of data records
•
Parameterization through AS-i bus with the help of data
records or an expanded process image from the user program
•
Control of the motor starter using a command data record from
the user program
•
Flexible assignment of the digital inputs and outputs with all
available assignable input actions
•
Parameterization using Motor Starter ES at the local interface
(ordering option for start up software)
•
Diagnostics with the help of Motor Starter ES (ordering option
for start up software)
Mounting and Installation
The M200D motor starters can be installed with a few manual
steps. The integrated plug-in technology enables far lower
wiring outlay. Connecting cables can be plugged directly onto
the motor starter module. Swapping of the connecting wires and
malfunctions within the plant are prevented by preassembled
cables. The AS-i bus is connected cost-effectively using an
M12 connection on the device. All versions feature identical
enclosure sizes, which simplifies system design and conversion.
Parameterization and configuration
The particularly robust M200D AS-i Standard motor starter is
characterized by numerous functions which can be flexibly
parameterized. It enables highly flexible parameterization
through the AS-i bus using data records from the user program
as well as user-friendly local parameterization using the
Motor Starter ES start up software through the local
point-to-point interface.
Functions can be flexibly assigned to the digital inputs and
outputs, adapting them to all possible conveyor applications.
All motor protection functions, limit values and reactions can be
defined by parameterization. The AS-i Standard is unique. In its
6E/4A process image the motor starter sends all four digital
inputs and the digital output via the process image to the PLC in
cyclic mode. System configuration and system documentation
are facilitated not least by a number of CAX data.
Operation
The new generation of motor starters is characterized by its
advanced functionality, maximum flexibility and extremely high
degree of automation.
All digital inputs and outputs exist in the cyclic process image.
All limit values for monitoring functions and their reactions are
parameterizable and therefore adaptable to the application. The
motor starters record the actual current flow. Evaluating the
current of the parameterizable solid-state overload protection
increases the availability of the drives, as do reliable messages
concerning the overshooting or undershooting of setpoint
values.
Diagnostics and maintenance
The M200D sets new standards for diagnostics. In addition to
diagnostics using the PAE process image and diagnostics by
"parameter echo" (up to 15 different diagnostic signals per slave
can be read out via AS-i communication), the possibility of
reading out diagnostic data records is unique on the market.
The AS-i Standard is recommended in particular for expansive
and highly automated system components because the possi-
bility of monitoring devices and systems with data records
(statistical data, measured values and device diagnostics)
provides an in-depth view of the plant from the control room,
guaranteeing the monitoring process and increasing plant
availability.
Preventive maintenance can be carried out with the integrated
maintenance timer and plant downtimes prevented as a result in
advance.
Local control of a drive is possible using the ordering option with
integrated manual operation. This is yet another new develop-
ment which distinguishes the M200D AS-i Standard motor starter
from the rest of the market and adds innovative technology,
maximum availability and transparency to the plant.
© Siemens AG 2016