Motor Starters for Use in the Field, High Degree of Protection
ET 200pro Motor Starters
General data
9
■
Technical specifications
1)
DS
....
Direct-on-line starters
RS
....
Reversing starters
DSS .. Direct-on-line soft starters
RSS .. Reversing soft starters
e
.......
Electronic motor protection
te
......
Full motor protection (thermal + electronic)
s
.......
Electronic switching with semiconductor.
2)
If the soft starter control function is deactivated, the permissible rated
operational current is reduced to 9 A up to CLASS 10.
3)
With parameterization as electronic starter max. 4 kW.
4)
8-hour operation.
5)
.
More information
"AS-Interface Basic" manual,
see
"AS-Interface Standard" manual,
see
Note on security:
For plant networking, suitable protective measures (including IT security,
e. g. network segmentation) must be taken to ensure safe operation of the
plant. For more
information about the subject of Industrial Security,
see
www.siemens.com/industrialsecurity
.
Type
Standard motor starters
High Feature motor starters
Mechanically switching
without inputs
Mechanically switching
with inputs
Mechanically switching
with inputs and soft
starter function
Technology designation
1)
DSe, RSe
DSe, RSe
sDSSte, sDSte,
sRSSte, sRSte
Mechanics and environment
Motor starters or modules that can be connected to ET 200pro
with 110 mm width
max. 8
Mounting dimensions (W x H x D)
• Direct-on-line starters and reversing starters
mm
110 x 230 x 150
110 x 230 x 160
Permissible ambient temperature
• During operation
°C
-25 ... +55, from +40 with derating
• During storage
°C
-40 ... +70
Permissible mounting position
Vertical, horizontal
Vibration resistance
acc. to IEC 60068, Part 2-6
g
2
Shock resistance
acc. to IEC 60068, Part 2-27
g
/ms
Half-sine 15/11
Degree of protection
IP65
Pollution degree
3, IEC 60664 (IEC 61131)
Electrical specifications
Current consumption at 24 V DC
• From auxiliary circuit L+/M (U1)
mA
Approx. 40
• From auxiliary circuit A1/A2 (U2)
mA
Approx. 200
Rated operational current
I
e
for power bus
A
25
Rated operational voltage
U
e
V AC
400 (50/60 Hz)
• Approval according to EN 60947-1, Appendix N
V AC
Up to 400 (50/60 Hz)
Up to 400 (50/60 Hz)
• Approval according to CSA and UL
V AC
Up to 600 (50/60 Hz)
Up to 480 (50/60 Hz)
Approval
• DIN VDE 0106, Part 101
V
Up to 400
Up to 480
• CSA and UL approval
V
Up to 600
Up to 480
Conductor cross-sections
• Incoming power supply
mm
2
max. 6 x 4
Touch protection
Finger-safe
Rated impulse withstand voltage U
imp
kV
6
Rated insulation voltage
U
i
V
400
Rated operational current for starters
I
e
• AC-1/2/3 at 40 °C
-
At 400 V
A
0.15 ... 2.0/1.5 ... 12.0
0.15 ... 2.0/1.5 ... 12.0
2)
-
At 500 V
A
0.15 ... 2.0/1.5 ... 9.0
• AC-4 at 40 °C
-
At 400 V
A
0.15 ... 2.0/1.5 ... 4.0
Rated short-circuit breaking capacity
kA
100 at 400 V
Type of coordination
acc. to IEC 60947-4-1
1
Power of three-phase motors at 400 V
kW
Max. 5.5
Max. 5.5/4
3)
Utilization categories
AC-1, AC-2, AC-3, AC-4
AC-53a
4)
(max. 9 A with
deactivated soft start
function up to
CLASS 10)
Protective separation between main and auxiliary circuits
V
400, acc. to EN 60947-1, Appendix N
Endurance of contactor
• Mechanical
Operating cycles
30 million
--
• Electrical
Operating cycles
Up to 10 million; depending on the current loading
(see manual
5)
)
--
Permissible switching frequency
Depending on the current load, motor starting time, and relative ON period
(see manual
5)
)
Switching times
at 0.85 ... 1.1 x
U
e
• Closing delay
ms
11 ... 50
--
• Opening delay
ms
5 ... 45
--