Overload Relays
SIRIUS 3RB3 Electronic Overload Relays
3RB30, 3RB31 for standard applications
7
■
Selection and ordering data
3RB30 electronic overload relays, CLASS 10E
Features and technical specifications:
•
Connection methods
- Sizes S00 and S0:
Main and auxiliary circuit: Either screw or spring-type
terminals
- Sizes S2 and S3:
Main circuit: Screw terminals with box terminal or as
straight-through transformer,
Auxiliary circuit: Either screw or spring-type terminals
•
Overload protection, phase failure protection and asymmetry
protection
•
Internal power supply
•
Auxiliary contacts 1 NO + 1 NC
•
Manual and automatic RESET
•
Switch position indicator
•
TEST function and self-monitoring
•
Sealable covers (optional accessory)
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41G
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
Maximum protection by fuse only for overload relays,
type of coordination "2".
For fuse values in connection with contactors,
see Configuration Manual
.
3)
With the appropriate terminal supports
(see "Accessories", page 7/100),
these overload relays can also be installed as stand-alone units.
Note:
For reliable operational current, note derating information,
see
Manual
.
Size
contactor
Rated power for
three-phase
motors,
rated value
1)
Current setting value of
the inverse-time
delayed overload
release
Short-circuit protection
with fuse, type of
coordination "2",
operational class gG
2)
SD
Screw terminals
SD
Spring-type
terminals
kW
A
A
d
Article No.
Price
per PU
d
Article No.
Price
per PU
Size S00
S00
Devices for mounting onto contactor
3)
0.04 ... 0.09
0.1 … 0.4
4
}
3RB3016-1RB0
2
3RB3016-1RE0
0.12 ... 0.37
0.32 … 1.25
6
}
3RB3016-1NB0
2
3RB3016-1NE0
0.55 ... 1.5
1 … 4
20
}
3RB3016-1PB0
2
3RB3016-1PE0
1.1 ... 5.5
3 … 12
25
}
3RB3016-1SB0
2
3RB3016-1SE0
2.2 ... 7.5
4 ... 16
25
}
3RB3016-1TB0
2
3RB3016-1TE0
Size S0
S0
Devices for mounting onto contactor
3)
0.04 ... 0.09
0.1 … 0.4
4
}
3RB3026-1RB0
2
3RB3026-1RE0
0.12 ... 0.37
0.32 … 1.25
6
}
3RB3026-1NB0
2
3RB3026-1NE0
0.55 ... 1.5
1 … 4
20
}
3RB3026-1PB0
2
3RB3026-1PE0
1.1 ... 5.5
3 … 12
25
}
3RB3026-1SB0
2
3RB3026-1SE0
3 ... 11
6 ... 25
50
}
3RB3026-1QB0
2
3RB3026-1QE0
5.5 ... 18.5
10 ... 40
50
}
3RB3026-1VB0
2
3RB3026-1VE0
Size S2
S2
Devices with screw terminals (main current side) and
for mounting onto contactor
3)
7.5 … 22
12.5 … 50
250
}
3RB3036-1UB0
}
3RB3036-1UD0
11 ... 37
20 ... 80
250
}
3RB3036-1WB0
}
3RB3036-1WD0
Devices with straight-through transformer for stand-alone
installation
7.5 … 22
12.5 … 50
250
}
3RB3036-1UW1
}
3RB3036-1UX1
11 ... 37
20 ... 80
250
}
3RB3036-1WW1
}
3RB3036-1WX1
Size S3
S3
Devices with screw terminals (main current side) and
for mounting onto contactor
3)
7.5 … 22
12.5 … 50
200
X
3RB3046-1UB0
X
3RB3046-1UD0
18.5 … 55
32 ... 115
315
X
3RB3046-1XB0
X
3RB3046-1XD0
Devices with straight-through transformer for stand-alone
installation
7.5 … 22
12.5 … 50
200
X
3RB3046-1UW1
X
3RB3046-1UX1
18.5 … 55
32 ... 115
315
X
3RB3046-1XW1
X
3RB3046-1XX1
3RB3016-1.B0
3RB3026-1.B0
3RB3036-1.B0
3RB3036-1.W1
3RB3046-1.B0
3RB3046-1.W1
© Siemens AG 2016