SIEMENS
4/49
Siemens IC 10 · 2017
Contactors for Special Applications
SIRIUS 3RT23 to 3RT26, 3RT13, 3RT14 contactors
4
■
Options
Rated control supply voltages, possible on request (change of the 10th and 11th digits of the Article No.)
Delivery time on request
1)
For deviating coil voltages and operating ranges of sizes S00 and S0,
a SITOP 24 V DC power supply with wide-range input can be used for the
coil control,
see page 15/1 onwards
.
2)
Coil operating range
-
at 50 Hz: 0.8 to 1.1 x
U
s
; at 60 Hz: 0.85 to 1.1 x
U
s
.
3)
Coil operating range
-
Size S00: at 50 Hz: 0.85 to 1.1 x
U
s
; at 60 Hz: 0.8 to 1.1 x
U
s
-
Sizes S0 to S3: at 50 Hz and 60 Hz: 0.8 to 1.1 x
U
s
.
4)
Coil operating range
-
Size S00: at 50/60 Hz: 0.85 to 1.1 x
U
s
-
Sizes S0 to S3: at 50 Hz: 0.8 to 1.1 x
U
s
; at 60 Hz: 0.85 to 1.1 x
U
s
.
5)
Coil operating range at 60 Hz: 0.8 to 1.1 x
U
s
.
1)
Operating range: 0.8 x
U
s min
to 1.1 x
U
s max
.
2)
Operating range: 0.7 x
U
s min
to 1.25 x
U
s max
.
Rated control supply
voltage
U
s
Contactor type
3RT231,
3RT251
3RT232,
3RT252
3RT233,
3RT253
3RT244
3RT134
3RT2617,
3RT262, 3RT263
Size
S00
S0
S2
S3
S00 to S2
Sizes S00 to S3
AC operation
1)
Solenoid coils for 50 Hz
(exception: Size S00: 50 and 60 Hz
2)
)
24 V AC
B0
B0
B0
B0
B0
B0
42 V AC
D0
D0
D0
D0
--
--
48 V AC
H0
--
--
H0
--
--
110 V AC
F0
F0
F0
F0
F0
F0
230 V AC
P0
P0
P0
P0
P0
P0
240 V AC
--
--
U0
U0
U0
--
400 V AC
V0
V0
V0
V0
V0
--
Solenoid coils for 50 and 60 Hz
2)
24 V AC
B0
C2
C2
C2
C2
C2
42 V AC
D0
D2
D2
D2
--
--
48 V AC
H0
H2
H2
H2
H2
--
110 V AC
F0
G2
G2
G2
--
--
220 V AC
N2
N2
N2
N2
N2
N2
230 V AC
P0
L2
L2
L2
L2
L2
Solenoid coils (for USA and Canada
3)
)
50 Hz
60 Hz
110 V AC
120 V AC
K6
K6
K6
K6
K6
--
220 V AC
240 V AC
P6
P6
P6
P6
--
--
Solenoid coils (for Japan)
50/60 Hz
4)
60 Hz
5)
100 V AC
110 V AC
G6
G6
G6
G6
--
G6
200 V AC
220 V AC
N6
N6
N6
N6
--
N6
400 V AC
440 V AC
R6
R6
R6
R6
--
R6
DC operation
1)
12 V DC
A4
A4
--
--
--
--
24 V DC
B4
B4
--
--
B4
B4
42 V DC
D4
D4
--
--
D4
--
48 V DC
W4
W4
--
--
W4
--
60 V DC
--
--
--
--
E4
--
110 V DC
F4
F4
--
--
F4
F4
125 V DC
G4
G4
--
--
G4
--
220 V DC
M4
M4
--
--
M4
--
230 V DC
P4
--
--
--
--
--
Examples
AC operation
3RT2325-1A
P0
0
Contactor with screw terminals; with solenoid coil for 50 Hz for rated control supply voltage of 230 V AC
3RT2325-1A
G2
0
Contactor with screw terminals; with solenoid coil for 50/60 Hz for rated control supply voltage of 110 V AC
DC operation
3RT2526-2B
B4
0
Contactor with spring-type terminals; for rated control supply voltage of 24 V DC
3RT2526-2B
G4
0
Contactor with spring-type terminals; for rated control supply voltage of 125 V DC
Rated control supply
voltage
Contactor type
3RT1456-6A,
3RT1466-6A,
3RT1476-6A
Rated control supply
voltage
Contactor type
3RT1456-6N,
3RT1466-6N,
3RT1476-6N
3RT1456-6P,
3RT1466-6P,
3RT1476-6P.
U
s min
...
U
s max
Size
S6, S10, S12
U
s min
...
U
s max
Size
S6, S10, S12
S6, S10, S12
Sizes S6 to S12
AC/DC operation (50/60 Hz AC, DC)
Conventional operating mechanisms
1)
Solid-state operating mechanisms
2)
23 ... 26 V AC/DC
B3
21 ... 27.3 V AC/DC
B3
--
42 ... 48 V AC/DC
D3
96 ... 127 V AC/DC
F3
F3
110 ... 127 V AC/DC
F3
200 ... 277 V AC/DC
P3
P3
200 ... 220 V AC/DC
M3
220 ... 240 V AC/DC
P3
240 ... 277 V AC/DC
U3
380 ... 420 V AC/DC
V3
440 ... 480 V AC/DC
R3
500 ... 550 V AC/DC
S3
575 ... 600 V AC/DC
T3
© Siemens AG 2016