Siemens IC 10 · 2017
IO-Link
Introduction
System components
2
IO-Link devices (continued)
Monitoring with IO-Link
Monitoring relays
SIRIUS 3RR24
SIRIUS 3RR24 monitoring relays for mounting
onto 3RT2 contactors for IO-Link
• Monitoring of current, phase failure, open circuit and
phase sequence
• Designed for mounting on 3RT2 contactors
• Terminal supports for stand-alone installation for
separate mounting
See page 10/70 onwards
Monitoring relays
SIRIUS 3UG48
SIRIUS 3UG48 monitoring relays for stand-alone
installation for IO-Link
• Monitoring network, voltage, current, power factor,
residual current or speed depending on device
design
• On/tripping delay time can be adjusted
See page 10/111 onwards
SIRIUS 3RS14 tem-
perature monitor-
ing relay
SIRIUS 3RS14, 3RS15 temperature monitoring
relays for IO-Link
• Temperature monitoring with connected sensors
• Two limit values, can be adjusted separately
See page 10/145 onwards
Actuating and indicating with IO-Link
SIRIUS ACT
3SU1 ID key-oper-
ated switches
SIRIUS ACT 3SU1 ID key-operated switches
for IO-Link
• Access system and selection system for four
authorization levels
• Authentication of groups and persons
• Five ID keys with different coding
• Option for individual coding via IO-Link
•
For installation in enclosures or fastening on front plate
• Electronic module for ID key-operated switches must
be ordered separately.
See page 13/9 onwards
SIRIUS ACT
3SU1 electronic
modules
SIRIUS ACT 3SU1 electronic modules for IO-Link
• Eight digital inputs and outputs possible
• DI and DQ freely selectable (programmable)
• Input and output functions parameterizable
• Connection system (push-in)
• For fastening on front plate;
see page 13/89
• For installation in enclosure;
see page 13/102
IO-Link RFID systems
RFID system for
IO-Link
SIMATIC RF200 RFID system in the HF range
Products SIMATIC RF210R, SIMATIC RF220R,
SIMATIC RF240R, SIMATIC RF250R, SIMATIC RF260R
• Simple identification tasks such as reading an
ID number (UID)
• Reading of user data
• Writing of user data
• No RFID-specific programming, ideal for those new to
RFID
• Simple connection via master modules for IO-Link,
such as SIMATIC S7-1200, ET 200SP, ET 200S,
ET 200eco PN and ET 200AL
• Use with the tried and tested ISO 15693 transponders
(MDS xxx)
See Catalog ID 10 "Industrial Identification Systems"
IO-Link IODD files
IO Device Description (IODD) files
provide the device description for IO-Link devices
• comprehensive IODD catalog of SIEMENS IO-Link
devices
• Freely available for downloading from
Industry Online Support;
see
IO-Link software
STEP 7 PCT
STEP 7 PCT (Port Configuration Tool)
Engineering software for configuring the IO-Link master
modules for SIMATIC S7-1200, ET 200SP,
ET 200eco PN and ET 200AL
• Available as a stand-alone version or integrated into
STEP 7 (V5.5 SP1 or later) and TIA (V12 or later)
• Engineering of the IO-Link devices connected to the
master
•
Monitoring of the process image of the IO-Link devices
• Open interface for importing further IODDs
• Freely available for downloading from
Industry Online Support;
see
IO-Link device
function block
IO-Link function blocks
(IO-Link device and IO-Link master)
STEP 7 function block for easy acyclical data exchange
in the user program
• Freely available for downloading from
Industry Online Support;
see
"Siemens IO-Link
Devices" function
block library
"Siemens IO-Link Devices" function block library
This library provides function blocks and user-defined
data types (UDTs) for all IO-Link devices from the Sie-
mens portfolio. These blocks and UDTs standardize
and simplify communication with IO-Link devices.
• Freely available for downloading from
Industry Online Support;
see
"IO_LINK_DEVICE"
WFB50001
END
DONE_VALID
BUSY
RD_LEN
ERROR
IOL_STATUS
STATUS
EN
REQ
ID
CAP
PORT
IOL_INDEX
IOL_SUBINDEX
LEN
DATA
RECORD_IOL_
RD_WR
IC01_00467
© Siemens AG 2016