SIEMENS
2/9
Siemens IC 10 · 2017
Industrial Communication
Introduction
2
AS-Interface: Slaves (continued)
Motor starters for use in the field, high degree of protection
SIRIUS M200D motor
starter
SIRIUS M200D motor starters for AS-Interface
• High degree of protection IP65 for cabinet-free design
• As direct-on-line or reversing starters for motors up to 5.5 kW/400 V
• Mechanical or electronic switching for high switching frequencies
• Optional with manual operation and brake control
• Expanded diagnostics and parameterization possible through AS-Interface
• Easy and consistent integration in STEP 7 through AS-Interface
Your advantage: The correct solution for all simple applications in conveyor systems
with spatially distributed drives.
3RK1
9/40
Motor starters for
AS-Interface, 24 V DC
Motor starters for AS-Interface, 24 V DC
• Degree of protection IP65/IP67
• Direct-on-line starters, double starters or reversing starters
• Up to 70 W
• Quick stop function
Your advantage: Simple motor starter in service-proven module design for 24 V DC motors.
3RK1
9/63
SINAMICS G110M
frequency inverters
SINAMICS G110M distributed inverters
Wide power range from 0.37 to 4 kW
• Preconfigured with SIMOGEAR
• Rugged, with IP65/IP66 degree of protection, up to 55 °C ambient temperature
• Local commissioning via DIP switch, standard USB interface and potentiometer or
Intelligent Operator Panel (IOP)
• Integrated safety functions (STO locally via F-DI or via PROFIsafe)
• Integrated, specific software functionality for conveyor systems
-
Quick stop function for fast reaction times to sensors
-
Limit switch functionality, e.g. for rotary table, corner transfer unit
Your advantage: the simple solution for compact drives with safety requirements in conveyor
technology
6SL3517 power
modules,
6SL3544 control
units
Catalog D 31
SINAMICS G110D
frequency inverters
SINAMICS G110D distributed inverters
High degree of protection IP65 for cabinet-free design
• Wide power range from 0.75 to 7.5 kW
• Easy commissioning and maintenance thanks to standardized plug-in connections for
bus, energy and I/Os
• Expanded diagnostics and parameterization through AS-Interface
• Optional maintenance switch
• Optional manual local operation
• Same connectors used as for the M200D motor starter
Your advantage: Easy, consistent implementation of distributed system concepts thanks to
scaling of SINAMICS G110D, SINAMICS G120D and SIRIUS M200D products.
6SL3511
Catalog D 31
Commanding and signaling devices
AS-Interface module
SIRIUS ACT pushbuttons and indicator lights for AS-Interface
• Modular configuration based on individual specifications, or as enclosure with standard
components
• AS-Interface modules for base mounting or mounting in enclosure
• Up to six command points for standard signals or EMERGENCY-STOP
• Degree of protection IP66/IP67/IP69K
• Metal or plastic version
• Indicator lights with integrated LED
• Any change of equipment possible even after installation
Your advantage: Complete operating system with simple AS-Interface connection
for your plant.
3SU14 modules
3SU18 enclo-
sures
13/89, 13/102
13/98
Signaling column
SIRIUS 8WD4 signaling columns
• Many optical and acoustic elements can be combined
• Up to three signaling elements can be connected using an adapter element
• With LEDs or incandescent lamps
Your advantage: Signaling columns for monitoring production sequences and for visual or
acoustic warnings in emergency situations, with easy AS-Interface connection.
8WD4
13/153
Article No.
Page
© Siemens AG 2016