SIEMENS
6/54
Siemens IK PI · 2015
Industrial Wireless Communication
IWLAN – Access Points IEEE 802.11n
SCALANCE W774 M12 EEC for enhanced environmental conditions
6
■
Technical specifications
Article No.
6GK5774-1FY00-0TA0
6GK5774-1FY00-0TB0
1)
Product-type designation
SCALANCE W774-1 M12 EEC
Transmission rate
Transmission rate
• with W-LAN maximum
300 Mbit/s
• with Industrial Ethernet
10 … 100 Mbit/s
• note
-
Interfaces
Number of electrical connections
• for network components
and terminal equipment
2
• for power supply
1
• for redundant power supply
1
Design of electrical connection
• for network components
and terminal equipment
M12 interface (4-pole, D-coded),
PoE
• for power supply
M12 interface (4-pole, A-coded)
Number of optical interfaces
for optical waveguide at 100 Mbit/s
-
Design of optical interface
for optical waveguide at 100 Mbit/s
-
design of the removable storage
C-PLUG
Yes
Interfaces
wireless
Number of radio cards permanently
installed
1
Number of internal antennas
-
Number of electrical connections
for external antenna(s)
2
Design of the electrical connection
for external antenna(s)
R-SMA (socket)
Product property external antenna
can be mounted directly on device
Yes
Signal-Inputs/outputs
Number of digital inputs
-
Number of digital outputs
-
Design of electrical connection
at the digital inputs/outputs
-
Signal range
• at digital input
-
• at the digital output
-
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
Supply voltage
• 1 from terminal block
19.2 V
• 2 from terminal block
28.8 V
• from Power-over-Ethernet
according IEEE802.3at for type 1
and IEEE802.3af
48 V
• from Power-over-Ethernet
according IEEE802.3at for type 2
-
Current consumed
• at 24 V with DC typical
-
• with Power-over-Ethernet
according to IEEE802.3at for type 1
and IEEE802.3af typical
-
• with Power-over-Ethernet
according to IEEE802.3at
for type 2 typical
-
Effective power loss
• at 24V for DC typical
-
• with Power-over-Ethernet
according to IEEE802.3at for type 1
and IEEE802.3af typical
-
• with Power-over-Ethernet
according to IEEE802.3at
for type 2 typical
-
Permitted ambient conditions
Ambient temperature
• during operating
-20 ... +60 °C
• during storage
-40 ... +85 °C
• during transport
-40 ... +85 °C
Relative humidity at 25 °C without
condensation during operating
maximum
100 %
Protection class IP
Ambient condition for (standard)
operation mode
When used under hazardous
conditions (Zone 2), the SCALANCE
W774-1 M12 EEC product must be
installed in an enclosure. To comply
with EN 50021, this enclosure must
meet the requirements of at least IP54
in compliance with EN 60529.
Design, dimensions and weight
Width of enclosure without antenna
26 mm
Height of enclosure without antenna
147 mm
Depth of enclosure without antenna
127 mm
Net weight
Mounting type wall mounting
Yes
Mounting type
Wall mounting only if flat mounted
Wireless frequencies
Radio frequency
• for WLAN in 2.4 GHz
frequency band
2.41 … 2.48 GHz
• for WLAN in 5 GHz
frequency band
4.9 … 5.8 GHz
Product properties, functions,
components
general
Product function
• Access Point Mode
Yes
• Client Mode
Yes
Number of SSIDs
4
Product function
• iPCF Access Point
in preparation
• iPCF client
in preparation
• iPCF-MC Access Point
-
• iPCF-MC client
in preparation
Number of iPCF-capable radio
modules
1
Article No.
6GK5774-1FY00-0TA0
6GK5774-1FY00-0TB0
1)
Product-type designation
SCALANCE W774-1 M12 EEC
© Siemens AG 2014