SIEMENS
6/38
Siemens IK PI · 2015
6
■
Technical specifications
(continued)
Industrial Wireless Communication
IWLAN – Access Points IEEE 802.11n
SCALANCE W786 RJ45 for outdoor use
Supply voltage,
current consumption, power loss
Type of supply voltage
DC
DC
DC
Supply voltage
• 1 from terminal block
19.2 V
19.2 V
19.2 V
• 2 from terminal block
28.8 V
28.8 V
28.8 V
• from Power-over-Ethernet
according IEEE802.3at for type 1
and IEEE802.3af
48 V
48 V
48 V
• from Power-over-Ethernet
according IEEE802.3at for type 2
50 V
50 V
50 V
• from optional integratable
power supply
-
with AC
100 … 240 V
100 … 240 V
100 … 240 V
-
with DC
12 … 24 V
12 … 24 V
12 … 24 V
Current consumed
• at 24 V with DC typical
0.45 A
0.63 A
0.63 A
• at 230 V with AC typical
0.05 A
0.07 A
0.07 A
• with Power-over-Ethernet
according to IEEE802.3at for type 1
and IEEE802.3af typical
0.22 A
0.22 A
0.22 A
• with Power-over-Ethernet
according to IEEE802.3at
for type 2 typical
-
-
-
Effective power loss
• at 24V for DC typical
10.7 W
15 W
15 W
• at 230 V with AC typical
10.7 W
15 W
15 W
• with Power-over-Ethernet
according to IEEE802.3at for type 1
and IEEE802.3af typical
10.7 W
15 W
10.7 W
• with Power-over-Ethernet
according to IEEE802.3at
for type 2 typical
-
-
-
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +60 °C
-40 … +60 °C
-40 … +60 °C
• during storage
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• during transport
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
Relative humidity at 25 °C without
condensation during operating
maximum
100 %
100 %
100 %
Protection class IP
IP65
IP65
IP65
Ambient condition for (standard)
operation mode
When using the power supply
100 to 240 V AC,
an operating temperature of
-40 °C to +60 °C is permissible
When using the power supply
100 to 240 V AC,
an operating temperature of
-40 °C to +60 °C is permissible
When using the power supply
100 to 240 V AC,
an operating temperature of
-40 °C to +60 °C is permissible
Design, dimensions and weight
Width of enclosure without antenna
251 mm
251 mm
251 mm
Height of enclosure without antenna
251 mm
251 mm
251 mm
Depth of enclosure without antenna
72 mm
72 mm
72 mm
Net weight
2.24 kg
2.24 kg
2.24 kg
Mounting type wall mounting
Yes
Yes
Yes
Mounting type
For mast mounting,
35 mm DIN rail mounting and S7-300
rail mounting, an additional support
plate is required
For mast mounting,
35 mm DIN rail mounting and S7-300
rail mounting, an additional support
plate is required
For mast mounting,
35 mm DIN rail mounting and S7-300
rail mounting, an additional support
plate is required
Wireless frequencies
Radio frequency
• for WLAN in 2.4 GHz
frequency band
2.41 … 2.48 GHz
2.41 … 2.48 GHz
2.41 … 2.48 GHz
• for WLAN in 5 GHz
frequency band
4.9 … 5.8 GHz
4.9 … 5.8 GHz
4.9 … 5.8 GHz
1)
Wireless approval in the USA
Article No.
6GK5786-1FC00-0AA0
6GK5786-2HC00-0AA0
6GK5786-2FC00-0AA0
6GK5786-1FC00-0AB0
1)
6GK5786-2HC00-0AB0
1)
6GK5786-2FC00-0AB0
1)
Product-type designation
SCALANCE W786-1 RJ45
SCALANCE W786-2IA RJ45
SCALANCE W786-2 RJ45
© Siemens AG 2014