SIEMENS
5/7
Siemens IK PI · 2015
IO-Link
Introduction
System components
5
■
Overview
(continued)
IO-Link components
1)
2)
3)
4)
IO-Link master, software, cables
Masters
CM 4xIO-Link
for ET 200SP
IO-Link masters for S7-1200
• SM1278 4xIO-Link
See page 5/9
IO-Link master modules for ET 200SP
• CM 4xIO-Link
See page 5/10
IO-Link master modules for ET 200S
• IO-Link 4SI electronic modules
• SIRIUS 4SI electronic modules
see pages 5/13
IO-Link master modules for ET 200eco PN
see page 5/14.
Software
STEP 7 PCT
STEP 7 PCT
Engineering software for configuring
the IO-Link master modules for S7-1200,
ET 200SP, ET 200S, ET 200eco
• Available as a stand-alone version or
integrated into STEP 7 (V5.5 SP1 or later) and
TIA (V12 or later)
• Retrieval of parameter and diagnostics data
from the IO-Link devices connected to the
master
• Monitoring of the process image of the
IO-Link devices
• Open interface for importing further IODDs
• Freely available for download from
Industry Online Support
1)
IO-Link Call
function block
IO-Link Call function block
STEP 7 function block for easy acyclical data
exchange in the user program
• Freely available for download from
Industry Online Support
2)
WinCC flexible
template project
WinCC flexible template project
Easy integration of IO-Link devices into the
user program by using ready-made WinCC
flexible templates
• Freely available for download from
Industry Online Support
3)
IODD files
IO-Link Device Description (IODD) files
provide the device description for IO-Link
• Comprehensive IODD catalog of SIEMENS
IO-Link devices
• Freely available for download from
Industry Online Support
4)
Cable
3-wire standard cable
see for example catalog ID 10 "Industrial
Identification Systems"
IO-Link devices
Detection with IO-Link
K20 input module
IO-Link input modules
K20 input module
• 4 inputs, M12 connections
• 8 inputs, standard M8 connections
See page 5/15
BOOL
IOL_CALL
DWORD
INT
DONE
BUSY
INT
INT
INT
RD_LEN
INT
ANY
BOOL
ERROR
IOL_STATUS
STATUS
BOOL
BOOL
INT
BOOL
DWO
DWO
REQ
ID
CAP
PORT
IOL_INDEX
IOL_SUBINDEX
LEN
RECORD_
IOL_DATA
RD_WR
IC01_0197
IO-Link devices
(continued)
SIMATIC RF210R,
SIMATIC RF220R,
SIMATIC RF260R
IO-Link RFID systems
SIMATIC RF200 RFID system in the HF range
• SIMATIC RF210R, SIMATIC RF220R,
SIMATIC RF260R products
• Simple identification tasks (read-only), such
as reading an ID number
• No RFID-specific programming, ideal for
those new to RFID
• Simple connection via master modules for
IO-Link, such as SIMATIC ET 200S and
ET 200eco
• Use with the tried and tested ISO 15693
transponders (MOBY D)
see Catalog ID 10 "Industrial Identification
Systems"
Switching with IO-Link
SIRIUS 3RA2711
function module for IO-Link
Contactors and contactor assemblies
Power contactors for switching motors
•
SIRIUS 3RT2 contactors, 3-pole, up to 18.5
kW
See page 5/18
Contactor assemblies
•
SIRIUS 3RA23 reversing contactor assemblies
• SIRIUS 3RA24 contactor assemblies for
wye-delta starting
See page 5/22
SIRIUS 3RA27 function modules for IO-Link
• For direct-on-line starters,
reversing starters and wye-delta starters
See page 5/24
SIRIUS 3RA64
direct-on-line starter
Motor starters for use in the
control cabinet
SIRIUS 3RA6 compact starters
• 3RA64 direct-on-line starters
• 3RA65 reversing starters
• Infeed system for 3RA6
see page 5/33
Contactors with IO-Link
SIRIUS 3RB24
overload relay
Overload relays
SIRIUS 3RB24 solid-state overload relays for
IO-Link
• Evaluation module
• Current measuring modules from 0.3 to 630 A
• Controlling direct-on-line, reversing and
star-delta starters via IO-Link in conjunction
with contactors
• Full motor protection
• Diagnostics and current value transmission
via IO-Link
See page 5/26
Monitoring with IO-Link
SIRIUS 3RR24
monitoring relay
SIRIUS 3RR24 monitoring relays for
IO-Link
• Monitoring of current, phase failure, open
circuit and phase sequence
• Designed for mounting on 3RT2 contactors
See page 5/36
SIRIUS 3UG48
monitoring relay
SIRIUS 3UG48 monitoring relays for
IO-Link
• Monitoring network, voltage, current, cos
,
residual current or speed depending on
device design
• On/tripping delay time can be adjusted
See page 5/43
SIRIUS 3RS14
temperature monitoring relay
SIRIUS 3RS14, 3RS15 temperature
monitoring relays for IO-Link
• Temperature monitoring with connected
sensors
• Two limit values, can be adjusted separately
See page 5/54