SIEMENS
4/121
Siemens IK PI · 2015
4
AS-Interface
Slaves
SINAMICS G110D distributed inverters
■
Benefits
•
Wide range of power ratings from 0.75 kW to 7.5 kW
•
Fast commissioning and maintenance as well as extended
diagnostic functions and communications capability with
AS-Interface according to Specification 3.0
- Reduced number of interfaces
- Plant-wide engineering
- Easy to handle
•
Mechanical design, installation and retrofit of systems are
significantly simplified as a result of the compact and space-
saving design with an extremely low profile and with the same
drilling dimensions for all power ratings; further, the dimen-
sions are identical with those of the SINAMICS G120D
inverter.
•
Simple commissioning and maintenance using the same,
standardized connectors for the bus, power and I/O connec-
tions (ISO 23570) for the complete power range of
SINAMICS G110D and SINAMICS G120D inverters.
•
The same connectors are used as for the SIRIUS M200D
motor starter
•
Simple, standard implementation of complete distributed
plant and system concepts by using products in a scalable
fashion:
- SIRIUS M200D (motor starter)
- SINAMICS G110D (inverter for basic, conveyor-related
applications)
- SINAMICS G110M (distributed inverter integrated in the
motor)
- SIMATIC ET 200pro FC-2 (available soon)
- SINAMICS G120D (inverter for sophisticated, conveyor-
related applications)
•
High degree of operator friendliness by using the Intelligent
Operator Panel (IOP) to parameterize, diagnose, control
(open-loop) and copy drive parameters in the BOP
•
Easy to replace using a plug-in design and the use of a
memory card provide the highest degree of service friend-
liness
•
Simple connection, engineering, data management as well as
control of the inverter in complex plants and systems as a
result of the consequential integration in TIA (Totally Integrated
Automation)
•
Using the optional maintenance switch, the inverter can be
simply disconnected from the line supply when service is
required, without any additional components or without
additional wiring costs when engineering the system
•
Using the optional manual local control, commissioning can
be carried out fast and limited to specific areas, the appli-
cation can be manually pre-tested on site and the system can
be cleared or emptied without requiring complex options.
•
By being able to connect up to five sensors directly at the unit,
practically all of the drive-relevant information can be directly
managed; local pre-processing of the signals relieves the
fieldbus to achieve fast and reproducible response times
•
Integrated class A EMC filter (acc. to EN 55011)
•
Integrated brake control, brake voltages supported: 180
V DC
and 205 V DC
•
Integrated motor protection using a thermal motor model and
evaluation of PTC, KTY or bimetal temperature sensors
•
Simple device replacement and fast copying of parameters to
the memory card using the optional memory card holder and
the optional memory card
•
Engineering and commissioning using standard engineering
tools such as SIZER (V3.2 and higher), STARTER (V4.1.3 and
higher) and Drive ES ensure fast engineering and simple
commissioning - STARTER is integrated into STEP 7 with Drive
ES Basic, with all of the benefits of central data management
and unified communication
•
Software parameters for easy adaptation to 50 Hz or 60 Hz
motors (IEC or NEMA motors)
•
Increased degree of ruggedness and longer service life as the
electronic modules are coated
•
Globally certified acc. to CE, UL, C-tick
■
Application
SINAMICS G110D is ideally suited for basic conveyor system
applications in the industrial environment for which a distributed
drive with communications capability is required. This is espe-
cially true for distribution logistics and for airports.
Further, SINAMICS G110D is suitable for many additional low-
performance applications in many sectors, e.g. in the
automotive sector, in the food and beverages industry (without
tensides) and in the packaging industry.
■
Selection and ordering data
1)
Rated power based on the rated output current
I
rated
. The rated output current
I
rated
is based on the duty cycle for high overload (HO).
2)
The rated output current
I
rated
is based on the duty cycle for high overload (high overload HO). These current values apply at 400 V
and are specified on the rating plate.
3)
500 V +10% is possible outside the UL range.
4)
Not governed by a specific standard.
Rated power
1)
Rated
output current
2)
Input current
Frame size
SINAMICS G110D
with integrated class A
line filter
SINAMICS G110D
with integrated class A
line filter and integrated
maintenance switch
kW
hp
A
A
Article No.
Article No.
380 … 500 V 3 AC
3)
0.75
1
2.3
2.0
FSA
6SL3511-0PE17-5AM0
6SL3511-1PE17-5AM0
1.5
1.5
4)
4.3
3.8
FSA
6SL3511-0PE21-5AM0
6SL3511-1PE21-5AM0
3
4
7.7
7.0
FSA
6SL3511-0PE23-0AM0
6SL3511-1PE23-0AM0
4
5
10.2
9.1
FSB
6SL3511-0PE24-0AM0
6SL3511-1PE24-0AM0
5.5
7.5
13.2
12.2
FSC
6SL3511-0PE25-5AM0
6SL3511-1PE25-5AM0
7.5
10
19.0
17.9
FSC
6SL3511-0PE27-5AM0
6SL3511-1PE27-5AM0
© Siemens AG 2014