SIEMENS
2/656
Siemens IK PI · 2015
2
■
Integration
(continued)
PROFINET/Industrial Ethernet
System interfaces for SIMATIC HMI
System interfaces with WinCC
SIMATIC WinCC
Mixed operation with different controls
With their multi-protocol stack, the CP 1613 and CP 5613 com-
munication processors allow parallel operation of two protocols,
such as for the mixed operation of different controls, via a bus
cable. WinCC supports the operation of two similar interface
boards only in connection with the channels SIMATIC S5 Ether-
net Layer 4 (2 x CP 1613), SIMATIC S7 Protocol Suite (2 x
CP 1613, 2 x CP 5613) as well as PROFIBUS DP (4 x CP 5613;
each CP 5613 max. 122 slaves). In addition to communication
over industrial Ethernet CP 1613 or PROFIBUS CP 5613, one CP
5611 can be used in each case for communication with SIMATIC
S7 via MPI.
Client-server communication
Communication between the clients and the server is via TCP/IP
protocol. Setting up a separate PC LAN is recommended. For
small projects with a correspondingly low incidence of message
frames, SIMATIC NET Industrial Ethernet communication can be
used for both process communication (WinCC/Server
PLC)
and PC-PC communication (WinCC/client
WinCC/server).
Channel DLL PROFIBUS DP
In accordance with the PROFIBUS standard, DP/slaves are al-
ways permanently assigned to a DP master; i.e. a second
WinCC station (DP/master) cannot access the same controls
(DP/slave). This means that redundant operation of two WinCC
stations is not possible using the PROFIBUS DP connection.
Connection to controls from other manufacturers:
OPC (OLE for Process Control) is recommended for the connec-
tion of controls from other manufacturers.
Current notes and information about OPC servers from various
suppliers can be found at:
WinCC supports the standards:
•
OPC Data Access 2.05a
•
OPC Data Access 3.00
•
OPC XML Data Access 1.00
(Connectivity Pack/Connectivity Station)
•
OPC HDA 1.20 (Connectivity Pack/Connectivity Station)
•
OPC A&E 1.10 (Connectivity Pack/Connectivity Station)
•
OPC UA Client Data Access
•
OPC UA Server Data Access, HDA
(Connectivity Pack / Connectivity Station)
Connection overview
1)
WinCC version V7.2 or higher supports communication
with S7-1200 / S7-1500 CPU.
Restrictions:
No symbolic address, type safe structure support (absolute address only)
No CPU alarming support
2)
Application note:
Parallel usage of the OPC client channel allows, for example, connection
to an SNMP-OPC server for visualization of the data contained there.
The SNMP OPC server enables monitoring of any network components
(such as switches) that support the SNMP protocol. You can find more
information under SIMATIC NET Communications Systems/SNMP OPC
Server.
3)
WinCC V7.0 SP3 and later supports OPC UA (United Architecture)
Client for DA.
Protocol
Description
SIMATIC S7
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions via MPI,
PROFIBUS or Ethernet Layer 4 +
TCP/IP
SIMATIC S5
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4
communication + TCP/IP
SIMATIC S5 Programmer Port AS511
Channel DLL and driver for serial
communication with S5 using AS511
protocol to programmers port
SIMATIC S5 Serial 3964R
Channel DLL and driver for serial
communication with S5 using RK512
protocol
SIMATIC S5 PROFIBUS-FDL
Channel DLL for S5-FDL
SIMATIC 505
SIMATIC 505 Serial
Channel DLL and driver for serial
communication with 505 using NITP/
TBP protocol to SIMATIC 535/545/
555/565/575
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4
communication
SIMATIC 505 TCP/IP
Channel DLL for 505 TCP/IP
communication
SIMATIC S7-1200, S7-1500 (WinCC 7.2 or higher)
SIMATIC S7-1200, S7-1500
Channel
1)
Channel DLL for S7-1200 and
S7-1500 communication
Controllers from other manufacturers (from WinCC V7.0 SP3)
Allen Bradley
Ethernet IP
Channel DLL and drivers for commu-
nication with Allen Bradley controllers
via Ethernet TCP/IP using Ethernet IP
protocol
Modbus TCP/IP
Channel DLL and drivers for commu-
nication with Modicon controllers via
Ethernet TCP/IP using Modbus TCP/
IP protocol
Mitsubishi MC TCP/IP
Channel DLL and drivers for commu-
nication with Mitsubishi controllers via
Ethernet TCP/IP using Mitsubishi MC
TCP/IP protocol
Cross-manufacturer
OPC Client
2) 3)
for DA, XML DA
Channel DLL for OPC communica-
tion, WinCC can acquire data from
OPC server applications.
OPC Server for DA, XML DA, A&E,
HDA
Server applications for OPC commu-
nication; WinCC provides process
data to OPC clients
OPC UA server for DA, HDA
Server applications for OPC UA
communication
PROFIBUS FMS
Channel DLL for PROFIBUS FMS
PROFIBUS DP
Channel DLL for PROFIBUS DP
SIMOTION
Channel DLL for SIMOTION
© Siemens AG 2014