System interfaces for SIMATIC HMI
System interfaces with WinCC (TIA Portal)
WinCC Runtime Communication
Coupling overview for WinCC Runtime Advanced
1)
HTTP and OPC communication can be used in combination with the other couplings; regarding SIMATIC Panels
that support HTTP or OPC communication, see the overview under "System interfaces (WinCC V11)".
2)
"SINUMERIK Operate WinCC RT Advanced" license required; for further information, see NC 60 Catalog.
3)
For detailed information regarding supported controllers, see "System interfaces (WinCC V11)"
4)
Application note:
Parallel use of the OPC client channel allows, for example, connection to an SNMP OPC Server for
visualization of the data present there.
The SNMP OPC Server enables monitoring of any network components (e.g. switches) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications systems/SNMP OPC Server.
Protocol
Description
PC interface
SIMATIC HMI
Ethernet TCP/IP
(HTTP communication)
HTTP communication for data exchange between SIMATIC HMI (client + server)
1)
CP 1612 A2
SIMATIC S7
Ethernet TCP/IP
(S7 communication)
Channel for communication via Ethernet TCP/IP with max. 8 x SIMATIC S7 controllers
S7-1200, S7-1500
S7-300, S7-400,
S7-200 with CP 243-1
CP 1612 A2
CP 1613 A2
CP 1623
SINUMERIK
2)
Ethernet TCP/IP
(S7 communication)
Channel for communication via Ethernet TCP/IP
with SINUMERIK 840D sl
CP 1612 A2
CP 1613 A2
CP 1623
Third-party controllers (from WinCC V11.0)
3)
Allen Bradley Ethernet IP
Channel for communication with max. 4 x Allen Bradley controllers
via Ethernet TCP/IP with Allen Bradley Ethernet IP protocol
The controllers ControlLogix / CompactLogix, SLC500 / MicroLogix and PLC5
are supported
CP 1612 A2
Allen Bradley DF1
Channel for communication with Allen Bradley controllers via DF1 protocol
The controllers SLC500 / MicroLogix and PLC5 are supported
3)
COM1/COM2
Mitsubishi MC TCP/IP
Channel for communication with max. 4 x Mitsubishi controllers via Ethernet TCP/IP
with Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD controller series are supported
CP 1612 A2
Mitsubishi FX
Channel for communication with Mitsubishi controllers via FX protocol
The FX1N, FX2N controllers are supported
COM1/COM2
Modbus TCP/IP
Channel for communication with max. 4 x Modicon controllers
via Ethernet TCP/IP using the Modbus TCP/IP protocol
The Quantum, Momentum, Premium, TSX Micro, Compact and M340 controllers
are supported
CP 1612 A2
Modbus RTU
Channel for communication with Modicon controllers via the Modbus RTU protocol
The Quantum, Momentum, and Compact controllers are supported
COM1/COM2
Omron Link / Multi Link
Channel for communication with Omron controllers via the Link/Multi protocol
The CP1x, CJ1x, CJ2H, CS1x, and CP2MC controllers are supported
COM1/COM2
Cross-manufacturer
OPC client
1) 4)
for
OPC DA, OPC UA DA, XML DA
Channel for OPC communication,
WinCC can acquire data from OPC server applications
CP 1612 A2
OPC server for OPC DA
Server applications for OPC communication;
WinCC provides process data to PC clients
CP 1612 A2