PROFINET/Industrial Ethernet
Communication for PC-based systems
CP 1613 A2
2
Performance data
Performance data
open communication
Software for open communication by
means of SEND/RECEIVE required
Yes, HARDNET-IE S7 (S7-1613)
Number of possible connections for
open communication by means of
SEND/RECEIVE maximum
120
Performance data
S7 communication
Software for S7 communication
required
Yes, HARDNET-IE S7 (S7-1613)
Number of possible connections
• for S7/PG communication
maximum
120
• for optimized S7 communication
maximum
40
Performance data
multi-protocol mode
Number of active connections
with multiprotocol mode
120
Number of configurable connections
per PC station
207
Performance data
PROFINET CBA
Software for PROFINET CBA
communication required
Yes, PN CBA OPC server
Number of remote connection part-
ners with PROFINET CBA
228
Number of connections
with PROFINET CBA total
10 000
Product functions
management,
configuration
Product function MIB support
Yes
Protocol is supported
• SNMP v1
Yes
• SNMP v3
No
• DCP
Yes
Configuration software
• required
included in scope of delivery of the
required software
• for PROFINET CBA required
Yes, SIMATIC iMAP
Identification & maintenance function
• I&M0 - device-specific information
Yes
• I&M1 - higher level
designation/location designation
Yes
Product functions
Redundancy
Software for redundancy function
required
Yes, HARDNET-IE S7-REDCONNECT
for communication with SIMATIC S7 H
systems
Product functions
Time
Product function SICLOCK support
Yes
Protocol is supported NTP
No
Standards, specifications,
approvals
Standard
• for EMC
2004/108/EC
• for safety of CSA and UL
CAN/CSA C22.2 & UL 60950-1,
UL 1950
• for emitted interference
EN 61000-6-3, EN 61000-6-4
• for interference immunity
EN 61000-6-1, EN 61000-6-2
Verification of suitability
• CE mark
Yes
• C-Tick
Yes
Article No.
6GK1161-3AA01
Product-type designation
CP 1613 A2
■
Ordering data
Article No.
1)
also S5-compatible communication
Note:
For software ordering data, see page 2/636
CP 1613 A2
communications processor
6GK1161-3AA01
PCI card (32-bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for
connection to Industrial Ethernet
(10/100 Mbit/s) with ITP and RJ45
connection over HARDNET-IE S7/
S7-1613 and S7-REDCONNECT,
for operating system support
see SIMATIC NET Software
Accessories
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
6XV1870-3QE50
• 1 m
6XV1870-3QH10
• 2 m
6XV1870-3QH20
• 6 m
6XV1870-3QH60
• 10 m
6XV1870-3QN10